利用基质辅助激光解吸电离质谱成像对兔VX2肿瘤进行脂质组学分析
本研究将VX2肿瘤植入四只兔的肝脏和两只兔的双侧胁腹,10-14天后取组织行MALDI-MSI正负离子模式检测。结果显示肝与胁腹肿瘤脂质谱不同:油酸定位于两部位存活肿瘤区,磷脂酸18:0/18:1仅见于肝肿瘤,磷脂酰肌醇18:2/18:0在胁腹肿瘤显著而肝肿瘤缺失。
要点
- 油酸(m/z 281.24)在两部位存活肿瘤区一致定位。
- 磷脂酸18:0/18:1(m/z 701.51)仅见于肝肿瘤。
- 磷脂酰肌醇18:2/18:0(m/z 861.55)在胁腹肿瘤显著而肝肿瘤缺失。
核心结论
- MALDI-MSI可实现VX2肿瘤内脂质分布的空间定位,揭示共有及部位特异性脂质改变,可能反映微环境驱动的脂质可塑性。
研究设计与样本
- 动物实验:VX2肿瘤植入四只兔肝脏和两只兔双侧胁腹,10-14天后取组织行MALDI-MSI正负离子模式检测,串联质谱辅助鉴定,脂质身份基于精确质量、碎裂模式和数据库匹配确定,分子离子分布与HE染色切片空间对应。
关键影像表现/征象
- 油酸(m/z 281.24)在两部位存活肿瘤区一致定位。
- 磷脂酸18:0/18:1(m/z 701.51)仅见于肝肿瘤。
- 磷脂酰肌醇18:2/18:0(m/z 861.55)在胁腹肿瘤显著,肝肿瘤缺失,但周围健康实质存在。
- 磷脂酰胆碱PC 34:1(m/z 798.52)、PC 36:2(m/z 808.56)和PC(P-36:2)(m/z 824.56)在两解剖部位呈异质性空间分布。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To characterize lipidomic profiles in the VX2 rabbit tumor model and assess potential lipid plasticity across tumor microenvironments in the liver and flank. Materials and Methods VX2 tumors were implanted into the liver in four rabbits and both flanks in two rabbits. After 10-14 days, tumor-containing tissues were harvested, snap frozen, sectioned, and analyzed using matrix-assisted laser desorption ionization mass spectrometry imaging (MALDI-MSI) in both positive and negative ion modes. Tandem mass spectrometry was used for further characterization. Lipid identities were determined based on accurate mass, fragmentation patterns, and database matching. Molecular ion distributions were spatially correlated with hematoxylin-eosin-stained sections. Results MALDI-MSI revealed distinct lipidomic profiles between liver and flank tumors. Oleate (mass-to-charge ratio [m/z] 281.24) was consistently localized to viable tumor regions in both sites. Phosphatidic acid 18:0/18:1(m/z 701.51) was detected in only liver tumors, whereas phosphatidylinositol 18:2/18:0 (m/z 861.55) was prominent in flank tumors but absent from liver tumors, despite being present in surrounding healthy parenchyma. Phosphatidylcholine (PC) species, notably PC 34:1 (m/z 798.52) and PC 36:2 (m/z 808.56), and PC (P-36:2) (m/z 824.56), showed heterogeneous spatial distributions across both anatomic sites. Conclusion MALDI-MSI enabled spatial mapping of lipid distributions within VX2 tumors, revealing both shared and site-specific alterations. These findings reveal heterogeneous spatial lipid distributions in the VX2 model and may reflect microenvironment-driven lipid plasticity. Keywords: Mass Spectrometry Imaging, VX2 Rabbit Tumor Model, Lipidomic Profiles, Ablation Techniques © RSNA 2026.
引用
- Khavandi MM, Crouch AC, Stolley DL, et al. Lipidomic Profiling of Rabbit VX2 Tumors Using Matrix-assisted Laser Desorption Ionization Mass Spectrometry Imaging. Radiol Imaging Cancer. 2026. PMID: 41823608. doi:10.1148/rycan.250588
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。