二维剪切波弹性成像与瞬时弹性成像测量肝脾硬度对高危静脉曲张的诊断准确性:一项前瞻性横断面研究
该前瞻性横断面研究纳入104例代偿期进展性慢性肝病患者,比较二维剪切波弹性成像与瞬时弹性成像测量肝硬度、脾硬度诊断高危静脉曲张的准确性。瞬时弹性成像脾硬度AUROC为0.917,最佳界值46.0 kPa;二维剪切波弹性成像脾硬度AUROC为0.790,界值35.5 kPa。基于二维剪切波弹性成像脾硬度与脾厚度的新模型诊断性能不劣于现有无创模型。
要点
- 瞬时弹性成像脾硬度诊断高危静脉曲张AUROC为0.917,最佳界值46.0 kPa
- 二维剪切波弹性成像脾硬度AUROC为0.790,最佳界值35.5 kPa
- 基于二维剪切波弹性成像脾硬度和脾厚度的新模型诊断性能不劣于现有无创模型
核心结论
- 瞬时弹性成像脾硬度和基于二维剪切波弹性成像的新无创模型有助于代偿期进展性慢性肝病患者的高危静脉曲张诊断。
研究设计与样本
- 前瞻性横断面研究,2023年10月至2025年3月连续纳入104例代偿期进展性慢性肝病成人患者(定义为瞬时弹性成像肝硬度≥10 kPa)且无既往失代偿。
诊断标准与关键数值
- 瞬时弹性成像肝硬度诊断高危静脉曲张AUROC为0.706(95%CI 0.533-0.879),最佳界值23.6 kPa。
- 瞬时弹性成像脾硬度诊断高危静脉曲张AUROC为0.917(95%CI 0.853-0.982),最佳界值46.0 kPa。
- 二维剪切波弹性成像肝硬度诊断高危静脉曲张AUROC为0.717(95%CI 0.545-0.889),最佳界值20.7 kPa。
- 二维剪切波弹性成像脾硬度诊断高危静脉曲张AUROC为0.790(95%CI 0.684-0.897),最佳界值35.5 kPa。
- 基于二维剪切波弹性成像脾硬度和脾厚度的诊断模型性能不劣于现有无创模型。
临床应用与阅片要点
- 代偿期进展性慢性肝病患者可接受瞬时弹性成像和二维剪切波弹性成像检查以无创评估高危静脉曲张。
- 瞬时弹性成像脾硬度46.0 kPa和二维剪切波弹性成像脾硬度35.5 kPa可作为诊断高危静脉曲张的参考界值。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Early detection of high-risk varices (HRV) in patients with compensated advanced chronic liver disease (cACLD) is crucial for improving prognosis. We aimed to compare the diagnostic accuracy of liver stiffness (LS) and spleen stiffness (SS) measured by two-dimensional shear wave elastography (2D-SWE) and transient elastography (TE) in the diagnosis of HRV, and to develop an HRV diagnostic model based on 2D-SWE for the patients with cACLD.
METHODS: From October 2023 to March 2025, 104 consecutive adult patients with cACLD (defined as TE measured LS ≥ 10 kPa) without previous decompensation were prospectively enrolled. All patients underwent TE and 2D-SWE examinations, laboratory tests and esophagogastroduodenoscopy (EGD) at enrollment.
RESULTS: The area under the receiver operating characteristics (AUROCs) (95% CI) of TE-based LS and SS for HRV were 0.706 (0.533-0.879) and 0.917 (0.853-0.982), with optimal cut-off value of 23.6 kPa and 46.0 kPa, respectively. The AUROCs (95%CI) for 2D-SWE based LS and SS were 0.717 (0.545-0.889) and 0.790 (0.684-0.897), with the cut-offs of 20.7 kPa and 35.5 kPa, respectively. We developed a diagnostic model using 2D-SWE-based SS and spleen thickness (ST), which demonstrated non‑inferior performance compared to established non‑invasive models.
CONCLUSIONS: TE-derived SS and our new non-invasive model based on 2D-SWE are useful for HRV diagnosis in patients with cACLD.
引用
- Jin C, He P, Xian J, et al. Diagnostic accuracy of liver and spleen stiffness measured by two-dimensional shear wave elastography and transient elastography for high-risk varices: A prospective cross-sectional study. Eur J Radiol. 2026. PMID: 41855769. doi:10.1016/j.ejrad.2026.112793
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。