大型血管总体流量测量:四维血流与二维相位对比磁共振成像的比较

Comparison of bulk flow measurements in the large vessels between four-dimensional flow (4D-flow) and two-dimensional phase contrast (2D-PC) magnetic resonance imaging (MRI).
PubMed 文献 · Clin Radiol · 2026-02-03

基于前瞻性4DCarE研究的大型队列,比较500例参与者升主动脉与主肺动脉的4D-flow与2D-PC总体流量测量,并使用两种商用软件分析4D-flow数据。4D-flow与2D-PC在正常与病理病例中均显示良好的内部一致性,但4D-flow无论使用何种软件均存在系统性低估。人工智能辅助图像标注在减少时间与劳动强度方面显示早期希望,但技术尚不成熟,需进一步开发与验证。

要点

  • 4D-flow测量升主动脉与主肺动脉总体流量时,较2D-PC存在系统性低估,与所用软件无关。
  • 在技术差异的局限内,4D-flow与2D-PC在正常及病理病例中均显示良好的内部一致性。
  • 人工智能辅助图像标注可减少时间与劳动强度,但技术尚处早期,需进一步开发与验证。

核心结论

  • 在大血管总体流量测量中,4D-flow与2D-PC在本大型队列中总体临床一致,但4D-flow较2D-PC显示系统性低估。

研究设计与样本

  • 前瞻性4DCarE研究的大型队列研究,纳入500例有正常或病理心脏病史的参与者,比较升主动脉与主肺动脉的4D-flow与2D-PC总体流量测量,并使用两种商用软件分析4D-flow测量值。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文指出4D-flow的临床整合仍因分析所需专业知识与资源而具挑战,且该技术尚无大规模系统性验证。
  • 原文指出4D-flow测量存在技术差异的局限。
  • 原文指出人工智能辅助图像标注技术尚处早期,需进一步开发与验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: The clinical integration of four-dimensional flow magnetic resonance imaging (4D-flow MRI) for cardiovascular assessment remains a challenge due to the expertise and resources required for analysis, and there is no large-scale systematic validation of the technique. We aim to evaluate the bulk flow measurements in the large vessels using 4D-flow MRI compared with conventional cardiac MRI in a large cohort as part of the prospective 4DCarE study.

MATERIALS AND METHODS: We conducted a large cohort prospective study to compare the bulk flow measurements in the ascending aorta and main pulmonary artery using 4D-flow and 2D phase contrast (2D-PC) MRI and analysed the 4D-flow measurements using two different commercially available software packages.

RESULTS: A total of 500 participants with a normal or pathological cardiac history were evaluated. Within the limitations of technical differences, 4D-flow demonstrated clinically consistent and reliable measurements compared with 2D-PC, although 4D-flow measurements showed a systematic bias towards undermeasurement compared with 2D-PC, irrespective of software used. Both 4D-flow and 2D-PC demonstrated good internal consistency for normal and pathological cases. The incorporation of artificial intelligence in the image annotation process showed early promises in reducing time and labour intensity and potentially improving the clinical integration of 4D-flow MRI, however, the technology remains nascent, and further development and validation are required.

CONCLUSION: Bulk flow measurements in the large vessels were grossly clinically consistent between 4D-flow and 2D-PC in this large cohort study, although 4D-flow showed systematic undermeasurement compared with 2D-PC.

来源:Clin Radiol,查看原文。版权归原作者所有。