文献速递心血管MR

灰阶反转亮血晚期钆增强可提高缺血性瘢痕检出的阅片者信心:一项多厂商研究

Grayscale-inverted bright-blood late gadolinium enhancement improves reader confidence in ischemic scar detection: a multivendor study.
PubMed 文献 · Eur J Radiol · 2026-03-14

本研究在单中心多厂商1.5 T设备上对120例患者(90例有缺血性瘢痕、30例无)行二维亮血晚期钆增强心脏磁共振,由9名不同经验水平阅片者比较标准图与灰阶反转图的诊断准确性和信心。结果显示两种显示方式诊断准确性相似(90.7% vs 91.9%,p=0.27),但灰阶反转显著提高阅片信心(3.25±0.81 vs 2.78±0.88,p<0.0001),以Level-1阅片者相对改善最大。

要点

  • 灰阶反转不改变诊断准确性,但显著提高阅片信心,尤其对低年资阅片者。
  • 标准图与反转图诊断准确性相似(90.7% vs 91.9%,p=0.27)。
  • 阅片者间一致性和透壁性可重复性在两种显示方式间保持不变。

核心结论

  • 灰阶反转亮血晚期钆增强显著提高阅片者信心,且不损害诊断准确性或阅片者间一致性。

研究设计与样本

  • 单中心多厂商研究,纳入120例患者(90例有缺血性瘢痕、30例无),在GE、Philips和Siemens 1.5 T扫描仪上行二维亮血晚期钆增强心脏磁共振。

关键影像表现/征象

  • 每例患者评估三个短轴层面,由九名阅片者(每个EACVI经验水平三名)判断瘢痕存在、透壁性和诊断信心(4分制)。
  • 以两名Level-3专家共识为参考标准。
  • 共34,560个节段水平评估,总体诊断准确性高(91.5%,95%CI 91.0-91.9%)。

诊断标准与关键数值

  • 标准图诊断准确性90.7% vs 反转图91.9%(p=0.27),不同经验水平及低透壁性病灶间无差异。
  • 灰阶反转后阅片信心显著提高(3.25±0.81 vs 2.78±0.88,p<0.0001)。
  • Level-1阅片者相对改善最大(2.63±0.89→3.00±0.83,p<0.001)。
  • 阅片者间一致性和透壁性可重复性保持不变,结果在各厂商间一致。

临床应用与阅片要点

  • 灰阶反转可作为亮血晚期钆增强阅片的辅助显示方式,可能支持培训和提升常规临床评估中的判读确定性(作者结论)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Bright-blood late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) is standard for myocardial scar detection, yet subendocardial infarcts may be difficult to identify due to limited scar-blood contrast. Grayscale inversion is a simple, vendor-independent post-processing technique that may enhance visual contrast. We assessed whether grayscale inversion improves diagnostic accuracy or reader confidence, and whether its effect varies by reader experience or scanner vendor.

METHOD: In this single-center, multivendor study, 120 patients (90 with and 30 without ischemic scar) underwent 2D bright-blood LGE on GE, Philips, and Siemens 1.5 T scanners. Three short-axis slices per patient were evaluated in standard bright-blood and grayscale-inverted visualizations by nine readers (three per EACVI experience level). Readers assessed scar presence, transmurality, and diagnostic confidence (4-point scale). Consensus of two Level-3 experts served as reference.

RESULTS: Across 34,560 segment-level assessments, diagnostic accuracy was high (91.5%, 95% CI 91.0-91.9%) and similar for standard vs. inverted images (90.7% vs. 91.9%, p = 0.27), with no differences across experience levels or in low-transmurality lesions. In contrast, reader confidence increased significantly with grayscale-inversion (3.25 ± 0.81 vs. 2.78 ± 0.88, p < 0.0001), with the greatest relative improvement among Level-1 readers (2.63 ± 0.89 → 3.00 ± 0.83, p < 0.001). Interobserver agreement and transmurality reproducibility remained unchanged. Results were consistent across vendors.

CONCLUSION: Grayscale-inverted bright-blood LGE significantly increases reader confidence without compromising diagnostic accuracy or interobserver agreement. This simple, vendor-neutral technique may support training and improve interpretive certainty in routine clinical LGE assessment.

来源:Eur J Radiol,查看原文。版权归原作者所有。