标准与超高分辨率光子计数冠状动脉CT血管成像衍生血流储备分数与有创血流储备分数评估的对比

Standard and Ultrahigh Resolution Photon-Counting Coronary CTA-Derived FFR Against Invasive FFR Assessment.
PubMed 文献 · JACC Cardiovasc Imaging · 2026-03-23

本研究在32例有有创冠状动脉造影临床指征的患者中,于有创造影前进行标准分辨率和超高分辨率光子计数冠状动脉CT血管成像,比较两种CT衍生血流储备分数与有创血流储备分数的一致性。结果显示两者均与有创血流储备分数相关,但超高分辨率在诊断准确度和血流动力学显著性分类上优于标准分辨率。

要点

  • 超高分辨率光子计数CT衍生血流储备分数与有创血流储备分数的相关性优于标准分辨率(ρ 0.728 vs 0.490)。
  • 超高分辨率在严重钙化及弥漫病变血管中仍保持与有创血流储备分数的相关性。
  • 超高分辨率诊断准确度AUC 0.93,优于标准分辨率AUC 0.80(P=0.012)。

核心结论

  • 标准分辨率和超高分辨率光子计数CT衍生血流储备分数均与有创血流储备分数相关,但超高分辨率在诊断准确度和血流动力学显著性分类上优于标准分辨率。

研究设计与样本

  • 研究类型为个体内比较研究;2023年2月至2025年4月纳入32例有有创冠状动脉造影临床指征的患者;采用光子计数冠状动脉CT血管成像标准分辨率和超高分辨率两种采集;以有创血流储备分数为参考标准;使用基于机器学习的原型软件计算CT衍生血流储备分数;共54支血管获得有创血流储备分数及两种CT衍生血流储备分数。

诊断标准与关键数值

  • 以有创血流储备分数<0.80为预测目标;标准分辨率CT衍生血流储备分数与有创血流储备分数相关系数ρ=0.490(P<0.001),超高分辨率ρ=0.728(P<0.001);严重钙化血管中超高分辨率ρ=0.577(P=0.039),弥漫病变血管中超高分辨率ρ=0.772(P=0.009);诊断准确度AUC:超高分辨率0.93 vs 标准分辨率0.80(P=0.012);血流动力学显著性分类一致性Cohen's κ:超高分辨率0.70 vs 标准分辨率0.50。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Coronary computed tomography angiography (CTA)-derived fractional flow reserve (FFR) serves as a gatekeeper to invasive coronary angiography (ICA), but its accuracy depends on image quality of the scan. Photon-counting coronary computed tomography angiography (PCCTA) technology enables spectral standard resolution (SR) and ultrahigh resolution (UHR) imaging.

OBJECTIVES: This study aims to perform the first intraindividual comparison of SR-PCCTA-derived FFR, UHR-PCCTA-derived FFR, and invasive FFR.

METHODS: Between February 2023 and April 2025, 32 patients with a clinical indication for ICA underwent research PCCTA with both SR and UHR acquisitions before ICA. Invasive FFR of intermediate coronary stenoses was measured. SR-PCCTA- and UHR-PCCTA-derived FFR were computed using an on-site, machine-learning-based prototype and compared with invasive FFR. Subanalyses were conducted in severely calcific and diffusely diseased vessels. Diagnostic accuracy for predicting invasive FFR <0.80 of SR-PCCTA- and UHR-PCCTA-derived FFR and concordance in hemodynamic significance classification (<0.80, ≥0.80) were assessed.

RESULTS: Invasive FFR, SR-PCCTA-, and UHR-PCCTA-derived FFR were available for 54 vessels. Both SR-PCCTA-derived (ρ: 0.490; P < 0.001) and UHR-PCCTA-derived FFR (ρ: 0.728; P < 0.001) correlated well with invasive FFR. Unlike SR-PCCTA, UHR-PCCTA-derived FFR maintained its correlation in severely calcific (ρ: 0.577; P = 0.039) and diffusely diseased vessels (ρ: 0.772; P = 0.009). UHR-PCCTA-derived FFR outperformed SR-PCCTA in diagnostic accuracy (AUC: 0.93 vs 0.80; P for comparison = 0.012) and hemodynamic significance classification (Cohen's κ: 0.70 vs 0.50).

CONCLUSIONS: Both SR-PCCTA- and UHR-PCCTA-derived FFR correlated with invasive FFR, but UHR-PCCTA outperformed SR-PCCTA in diagnostic accuracy and hemodynamic significance classification.

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Portolan L, Kotronias RA, Andreaggi S, et al. Standard and Ultrahigh Resolution Photon-Counting Coronary CTA-Derived FFR Against Invasive FFR Assessment. JACC Cardiovasc Imaging. 2026. PMID: 41874496. doi:10.1016/j.jcmg.2026.02.014