超高清光子计数探测器CT评估冠状动脉支架内再狭窄:一项双中心研究结果
本研究以有创冠状动脉造影为参考,回顾性纳入两个学术中心的50例患者共106枚冠状动脉支架,评估超高清光子计数探测器CT对阻塞性与非阻塞性支架内再狭窄的诊断准确性。0.2 mm超高清重建较0.4 mm标准分辨率重建提高了可评估支架比例及非阻塞性和阻塞性再狭窄的敏感度、特异度与准确率,小口径支架(<3 mm)中准确率亦更高。
要点
- 0.2 mm超高清重建使可评估支架比例从91.5%提高至99.1%。
- 非阻塞性再狭窄:0.2 mm超高清敏感度90.5%、特异度100.0%、准确率96.2%,均高于0.4 mm重建的82.9%、78.5%、80.2%。
- 阻塞性再狭窄:0.2 mm超高清特异度98.7%、阳性预测值96.3%、准确率98.1%,高于0.4 mm重建的82.3%、64.1%、84.9%。
核心结论
- 超高清光子计数探测器CT诊断准确性优秀,较准标准分辨率重建显著改善支架内再狭窄检出,包括非阻塞性再狭窄和小口径支架再狭窄。
研究设计与样本
- 回顾性双中心研究,连续纳入50例患者(女性16.0%,年龄70.9±10.8岁)共106枚冠状动脉支架,均行临床指征下双源光子计数探测器CT冠状动脉CT血管成像,以有创冠状动脉造影为参考标准。
关键影像表现/征象
- 0.2 mm超高清重建检出非阻塞性再狭窄10枚支架,0.4 mm类能量积分探测器标准分辨率重建检出14枚。
- 0.2 mm超高清重建描述阻塞性再狭窄26枚支架,0.4 mm重建描述32枚。
- 可评估支架比例从0.4 mm重建的91.5%提高至0.2 mm超高清的99.1%。
诊断标准与关键数值
- 非阻塞性支架内再狭窄定义为狭窄<50%,阻塞性定义为狭窄≥50%,以有创冠状动脉造影为参考。
- 非阻塞性再狭窄:0.2 mm超高清敏感度90.5%、特异度100.0%、准确率96.2%;0.4 mm标准分辨率敏感度82.9%、特异度78.5%、准确率80.2%。
- 阻塞性再狭窄:0.2 mm超高清特异度98.7%、阳性预测值96.3%、准确率98.1%;0.4 mm标准分辨率特异度82.3%、阳性预测值64.1%、准确率84.9%。
- 小口径支架(<3 mm):0.2 mm超高清对非阻塞性再狭窄准确率94.1%、对阻塞性再狭窄准确率94.1%;0.4 mm标准分辨率分别为73.5%和79.4%。
临床应用与阅片要点
- 采用0.2 mm超高清重建可提高支架可评估性,减少因支架伪影导致的不可评估情况。
- 报告支架内再狭窄时需区分非阻塞性(<50%)与阻塞性(≥50%),0.2 mm超高清对两者诊断准确性均优于0.4 mm类标准分辨率重建。
- 小口径支架(<3 mm)中0.2 mm超高清准确率高于0.4 mm重建,评估此类支架时优先选择超高清重建。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
INTRODUCTION: To assess the diagnostic accuracy of ultrahigh-resolution (UHR) photon-counting detector (PCD)-CT for detecting obstructive and non-obstructive coronary in-stent restenosis (ISR), using invasive coronary angiography (ICA) as the reference.
METHODS: Consecutive patients with coronary stents who underwent clinically indicated coronary CT angiography (CCTA) on a dual-source PCD-CT were retrospectively identified from two academic centers. All UHR scans were reconstructed at 0.2 mm and 0.4 mm slice thickness, the latter served as an energy-integrating detector CT-like proxy. Series were assessed for the presence of non-obstructive (<50%) and obstructive (≥50%) ISR, with diagnostic accuracy validated against ICA in the overall cohort and in a sub-analysis of stents < 3 mm in diameter.
RESULTS: Fifty patients (16.0% women; 70.9 ± 10.8 years) with 106 coronary stents were included. ICA identified 17 non-obstructive and 27 obstructive ISR. Non-obstructive ISR was detected in 10 stents on 0.2 mm UHR and 14 on 0.4 mm EID-like standard-resolution reconstructions.Obstructive ISR was described in 26 (0.2 mm) vs. 32 (0.4 mm) stents, respectively. The proportion of evaluable stents increased from 91.5% based on 0.4 mm to 99.1% with 0.2 mm UHR. Compared with standard-resolution images, 0.2-mm UHR improved non-obstructive ISR sensitivity (90.5%vs82.9%), specificity (100.0%vs78.5%), and accuracy (96.2%vs80.2%); and in obstructive ISR, specificity (98.7%vs82.3%), positive predictive value (96.3%vs64.1%), and accuracy (98.1%vs84.9%). Thin-slice UHR achieved higher accuracy in small-caliber stents (<3mm), for both non-obstructive (94.1vs73.5%) and obstructive ISR (94.1%vs79.4%).
CONCLUSION: UHR PCD-CT demonstrated excellent diagnostic accuracy and significant improvements in ISR detection compared to the quasi-standard reconstructions, including non-obstructive and small-caliber stent ISR.
引用
- Szilveszter B, Hagar MT, Kulyassa P, et al. Assessing coronary in-stent restenosis using ultrahigh-resolution photon-counting detector CT: results from a two-center study. Eur J Radiol. 2026. PMID: 41849865. doi:10.1016/j.ejrad.2026.112766
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。