文献速递头颈外周血管技术与安全USCT

放射后颈总动脉狭窄的双功能超声诊断效能:横断面验证研究

Diagnostic Performance of Duplex Ultrasonography in Post-Radiation Common Carotid Artery Stenosis: A Cross-Sectional Validation Study.
PubMed 文献 · J Ultrasound Med · 2026-03-08

本研究纳入134例头颈癌患者共268条颈动脉,以CTA≥50%狭窄为参考标准,验证双功能超声对放射性颈总动脉狭窄的诊断准确性;B模式50%阈值的敏感度85.2%、特异度88.1%,最优B模式阈值53%的AUROC为0.894,PSV 203 cm/s阈值敏感度51.7%、特异度99.2%,联合B模式与PSV的AUROC为0.891,较单用B模式增量获益有限。

要点

  • B模式超声以50%阈值筛查放射性颈总动脉≥50%狭窄,敏感度85.2%、特异度88.1%。
  • B模式最优阈值53%的AUROC为0.894,优于PSV阈值203 cm/s的AUROC 0.698。
  • 联合B模式与PSV的AUROC为0.891,较单用B模式增量诊断获益有限。

核心结论

  • B模式双功能超声可能是筛查放射性颈总动脉狭窄的可行工具,B模式阈值53%对检出≥50%狭窄的诊断效能与联合B模式和流速标准相当。

研究设计与样本

  • 横断面验证研究,纳入134例头颈癌患者共268条颈动脉,均行双功能超声和计算机断层血管造影,以CTA≥50%狭窄为参考标准。

关键影像表现/征象

  • B模式评估直径狭窄率,血流动力学参数在双功能超声上测量。
  • B模式阈值53%时敏感度75.9%、特异度91.4%、PPV 51.2%、NPV 96.9%,AUROC 0.894。
  • PSV阈值203 cm/s时敏感度51.7%、特异度99.2%、PPV 88.2%、NPV 94.6%,AUROC 0.698。

诊断标准与关键数值

  • 以CTA≥50%颈总动脉狭窄为参考标准,B模式50%阈值诊断敏感度85.2%、特异度88.1%、PPV 45.1%、NPV 98.1%。
  • B模式最优阈值53%时敏感度75.9%、特异度91.4%、PPV 51.2%、NPV 96.9%,AUROC 0.894。
  • PSV最优阈值203 cm/s时敏感度51.7%、特异度99.2%、PPV 88.2%、NPV 94.6%,AUROC 0.698。
  • 联合B模式与PSV标准的AUROC为0.891。

临床应用与阅片要点

  • B模式双功能超声可能作为放射性颈总动脉狭窄的筛查工具。
  • B模式阈值53%对检出≥50%狭窄的诊断效能与联合B模式和流速标准相当。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Whether established diagnostic criteria of carotid duplex ultrasonography (CDU) for atherosclerotic carotid artery stenosis are applicable to radiation vasculopathy in head and neck cancer (HNC) patients remains uncertain. This study aimed to validate the diagnostic accuracy of CDU for screening radiation-induced common carotid artery (CCA) stenosis.

METHODS: We enrolled 134 HNC patients with 268 carotid arteries, all of whom underwent CDU and computed tomographic angiography. Diameter stenosis and hemodynamic parameters were assessed on CDU, with ≥50% stenosis on computed tomographic angiography serving as the reference standard. Diagnostic performance was evaluated using sensitivity, specificity, PPV, NPV, and receiver operating characteristic (ROC) analysis to identify optimal cutoff values.

RESULTS: Using a B-mode cutoff of 50% to detect ≥50% CCA stenosis, the sensitivity, specificity, PPV, and NPV were 85.2, 88.1, 45.1, and 98.1%, respectively. The optimal B-mode threshold of 53%, which yielded a sensitivity of 75.9%, specificity of 91.4%, PPV of 51.2%, and NPV of 96.9%, with an area under the ROC curve (AUROC) of 0.894. In comparison, the optimal PSV threshold of 203 cm/s showed lower sensitivity (51.7%) but higher specificity (99.2%), with a PPV of 88.2%, NPV of 94.6%, and an AUROC of 0.698. Combining B-mode and PSV criteria resulted in an AUROC of 0.891, offering minimal incremental diagnostic benefit compared with B-mode assessment alone.

CONCLUSIONS: B-mode CDU may be a feasible screening tool for radiation-induced CCA stenosis. A B-mode threshold of 53% achieved diagnostic performance comparable to combined B-mode and velocity criteria for detecting ≥50% stenosis.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Chen MS, Jiang JL, Yeh CH, et al. Diagnostic Performance of Duplex Ultrasonography in Post-Radiation Common Carotid Artery Stenosis: A Cross-Sectional Validation Study. J Ultrasound Med. 2026. PMID: 41795643. doi:10.1002/jum.70232

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。