文献速递神经头颈CT

颞骨锥形束CT:内耳结构的规范性线性生物测量

Conebeam CT of the Temporal Bone: Normative Linear Biometry of Inner Ear Structures.
PubMed 文献 · AJNR Am J Neuroradiol · 2026-10-29

本研究回顾性分析2022年6月至2024年6月间正常颞骨锥形束CT扫描,由2名放射科医师独立完成11项内耳结构线性测量并评估观察者间一致性,建立各参数的参考百分位数。共纳入319例患者(男135例,女184例;平均年龄50.03岁;范围3个月至91岁),观察者间信度高,年龄和性别对测量仅有小影响,为先天性听力损失的放射学评估提供参考值。

要点

  • 建立了11项内耳结构基于锥形束CT的线性测量参考百分位数。
  • 所有测量观察者间信度高,年龄和性别对测量仅有小影响。
  • 参考值可能改善先天性听力损失的放射学评估,尤其CT表现正常者。

核心结论

  • 本研究提供了基于锥形束CT的内耳结构稳健的规范性线性测量值,这些参考值可能改善先天性听力损失的放射学评估,尤其适用于CT表现正常的患者。

研究设计与样本

  • 回顾性研究,连续纳入2022年6月至2024年6月间采集的正常颞骨锥形束CT扫描,共319例患者(男135例,女184例;平均年龄50.03岁;范围3个月至91岁),由2名放射科医师独立完成11项内耳结构线性测量并评估观察者间一致性。

诊断标准与关键数值

  • 为11项内耳结构建立参考百分位数分布;所有测量观察者间信度高;年龄和性别对任何测量仅有小影响。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Normative linear measurements of inner ear structures may enhance diagnostic accuracy in detecting subtle congenital abnormalities. This study aimed to establish conebeam CT (CBCT)-based normative reference values for temporal bone anatomy.

MATERIALS AND METHODS: We retrospectively reviewed consecutive CBCT scans of normal temporal bones acquired between June 2022 and June 2024. Scans were classified as normal based on the absence of pathologic findings and no history of otologic disorders. Eleven linear measurements of inner ear structures were independently performed by 2 radiologists, and interobserver agreement was assessed. Reference centiles were generated for each parameter.

RESULTS: A total of 319 patients (135 men, 184 women; mean age, 50.03 years; range, 3 months-91 years) were included. Interobserver reliability was high across all measurements. Age and sex showed a small effect on any measurement. Normative centile distributions for all 11 structures were established.

CONCLUSIONS: This study provides robust CBCT-derived normative linear measurements of inner ear structures. These reference values may improve radiologic assessment of congenital hearing loss, particularly in patients with normal-appearing CT examinations.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Conte G, Schifano E, Massullo E, et al. Conebeam CT of the Temporal Bone: Normative Linear Biometry of Inner Ear Structures. AJNR Am J Neuroradiol. 2026. PMID: 41862187. doi:10.3174/ajnr.A9302

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。