文献速递神经外周血管CTDSA

人工智能迭代重建的灌注衍生脑CT血管成像替代急性缺血性卒中常规脑CT血管成像

Perfusion-derived cerebral CT angiography with artificial intelligence iterative reconstruction as a replacement for routine cerebral CT angiography in acute ischemic stroke.
PubMed 文献 · Eur J Radiol · 2026-03-25

前瞻性收集62例急性缺血性卒中患者,比较灌注衍生脑CTA分别用混合迭代重建(A1组)和人工智能迭代重建(A2组)与常规CTA用混合迭代重建(B组)对颅内动脉闭塞的诊断效能,以DSA为参考标准。A2组与B组诊断效能相当,且均优于A1组;A2组图像质量主观评分最高、噪声最低、CNR最高。

要点

  • 灌注衍生CTA经AIIR重建(A2组)检测颅内动脉闭塞的敏感度93.7%、特异度97.5%、准确率97.3%,与常规CTA(B组)相当。
  • A2组与B组在所有诊断指标上均优于A1组(混合迭代重建的灌注衍生CTA),所有p<0.001。
  • A2组小血管可见性评分5[5,5]高于B组4[4,5]和A1组3[3,3],且图像噪声最低、CNR最高。

核心结论

  • 灌注衍生脑CTA采用AIIR重建对急性缺血性卒中患者可获得与常规CTA相当的诊断图像质量。

研究设计与样本

  • 前瞻性收集62例(33-93岁)急性缺血性卒中患者,同期行脑CTP和CTA;CTP动脉期(100kVp/150mAs)衍生CTA分别用混合迭代重建(A1组)和AIIR(A2组)重建,常规CTA(100kVp/参考200mAs)用混合迭代重建(B组);以DSA为参考标准,两名放射科医师独立评估。

关键影像表现/征象

  • A2组与B组检测颅内动脉闭塞的敏感度均为93.7%,特异度分别为97.5%和98.0%,准确率分别为97.3%和97.7%。
  • A2组与B组在所有诊断指标上均优于A1组(所有p<0.001)。
  • A2组主观评分显著高于A1组和B组(所有p<0.001),小血管可见性评分A2组5[5,5]、B组4[4,5]、A1组3[3,3]。
  • A2组在所有动脉测量中图像噪声最低、CNR最高。

诊断标准与关键数值

  • 以DSA为参考标准,A2组检测颅内动脉闭塞敏感度93.7%、特异度97.5%、准确率97.3%。
  • B组检测颅内动脉闭塞敏感度93.7%、特异度98.0%、准确率97.7%。
  • A2组与B组敏感度比较p=1.000,特异度比较p=0.383,准确率比较p=0.383。

临床应用与阅片要点

  • 灌注衍生CTA经AIIR重建对颅内动脉闭塞的诊断效能与常规CTA相当,且主观图像质量评分更高。
  • A2组小血管可见性评分5[5,5]高于B组4[4,5]和A1组3[3,3],提示AIIR重建可能有利于显示小血管。
  • A2组图像噪声最低、CNR最高,覆盖颈内动脉、大脑中动脉和基底动脉的测量。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To investigate the feasibility of replacing routine cerebral CT angiography (CTA) with CT perfusion (CTP)-derived cerebral CTA by using artificial intelligence iterative reconstruction (AIIR) for acute ischemic stroke (AIS) patients.

METHODS: Patients with AIS undergoing cerebral CTP and CTA were prospectively collected. CTA images derived from CTP at arterial phase (100kVp/150mAs) were reconstructed with hybrid iterative reconstruction (HIR, Group A1) and AIIR (Group A2), whereas routine CTA images (100kVp/ref. 200mAs) were obtained with HIR (Group B). Two radiologists independently assessed these three image sets for intracranial artery occlusion, with digital subtraction angiography (DSA) serving as the reference standard. Image noise suppression, vascular edge sharpness, small vessel visibility and overall diagnostic acceptability were graded using five-point Likert scales. Noise and contrast-to-noise ratio (CNR) of internal carotid artery, middle cerebral artery and basilar artery were also measured.

RESULTS: Of the 62 enrolled patients (33-93 y), DSA identified 63 arterial occlusions in 54 patients (87.1%). For occlusion detection, Groups A2 and B provided comparable diagnostic performance (Sensitivity: 93.7% vs. 93.7%, p = 1.000; Specificity: 97.5% vs. 98.0%, p = 0.383; Accuracy: 97.3% vs. 97.7%, p = 0.383). Both Groups A2 and B outperformed Group A1 on all diagnostic metrics (all p < 0.001). For qualitative analysis, Group A2 received significantly higher scores than both Groups A1 and B (all p < 0.001), particularly for small vessel visibility (5 [5,5] vs. 3 [3,3] vs. 4 [4,5]). Additionally, Group A2 exhibited the lowest image noise and highest CNR across all arterial measurements.

CONCLUSIONS: Perfusion-derived cerebral CTA with AIIR achieves comparable diagnostic image quality to that of routine CTA for AIS patients.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Huang J, Wang M, Wang T, et al. Perfusion-derived cerebral CT angiography with artificial intelligence iterative reconstruction as a replacement for routine cerebral CT angiography in acute ischemic stroke. Eur J Radiol. 2026. PMID: 41905136. doi:10.1016/j.ejrad.2026.112819

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。