自由呼吸深度学习重建单次激发电影MRI在疑似心律失常参与者中的可行性:与传统分段电影MRI的比较
研究前瞻性纳入25名健康志愿者和45名疑似心律失常参与者,在1.5-T扫描仪上比较深度学习增强压缩感知(AI-CS)单次激发电影序列与传统bSSFP电影序列对左心室结构和功能的评估。AI-CS图像质量更优(尤其在心律失常者中),与bSSFP在双心室容积和左心室质量测量上一致性良好至优秀,扫描时间显著缩短,在bSSFP失败病例中提供的射血分数与超声心动图相当。
要点
- AI-CS单次激发电影序列图像质量优于bSSFP,心律失常参与者中伪影和误触发更少。
- AI-CS与bSSFP在双心室容积和左心室质量测量上一致性良好至优秀。
- AI-CS扫描时间显著缩短(10秒±2 vs 132秒±8,P<.001)。
核心结论
- AI-CS单次激发电影序列在健康参与者和疑似心律失常参与者中显示出比bSSFP电影序列更高的图像质量和临床可行性。
研究设计与样本
- 前瞻性研究,2023年9月1日至2024年9月28日招募25名健康志愿者和45名疑似心律失常参与者,在1.5-T扫描仪上均行bSSFP和AI-CS单次激发短轴电影成像,采用Wilcoxon符号秩检验比较左心室容积参数和应变参数。
关键影像表现/征象
- 心律失常参与者中,AI-CS单次激发电影序列的欧洲心血管磁共振登记评分低于bSSFP电影序列(0.05±0.22 vs 0.32±0.68,P<.001),提示图像质量更优。
- AI-CS单次激发电影序列的误触发事件和心脏运动伪影更少。
- bSSFP失败病例中,AI-CS提供的射血分数与超声心动图相当(37.50%±5.28 vs 31.70%±6.43;z=-1.864;P=.06)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To evaluate the feasibility of retrospective electrocardiographically (ECG) gated single-shot cine using deep learning-enhanced compressed sensing (AI-CS) versus conventional balanced steady-state free precession (bSSFP) cine, focusing on left ventricular (LV) structure and function. Materials and Methods Between September 1, 2023, and September 28, 2024, participants (including those with suspected arrhythmias) were prospectively recruited to undergo short-axis cine imaging with both bSSFP and AI-CS single-shot sequences on a 1.5-T scanner. LV volumetric parameters (LV end-diastolic volume, end-systolic volume, stroke volume, ejection fraction, and mass) and strain parameters (peak strain in the radial, longitudinal, and circumferential directions and the time to peak strain SD) were measured and compared using Wilcoxon signed rank tests. Results Among 25 healthy volunteers (mean age, 37.88 years ± 16.76 [SD]; 18 female) and 45 participants with suspected arrhythmia (mean age, 53.21 years ± 15.45; 20 female), the AI-CS single-shot cine had better image quality compared with bSSFP cine, particularly in participants with arrhythmia (European Cardiovascular Magnetic Resonance Registry score: 0.32 ± 0.68 for bSSFP cine vs 0.05 ± 0.22 for AI-CS single-shot cine; P < .001), with fewer mistrigger events and cardiac motion artifacts. AI-CS showed good to excellent agreement with bSSFP for biventricular volume and LV mass measurements and provided comparable ejection fraction values to those at echocardiography in cases in which bSSFP failed (37.50% ± 5.28 vs 31.70% ± 6.43; z = -1.864; P = .06). Scan time was significantly reduced with AI-CS (10 seconds ± 2 vs 132 seconds ± 8; P < .001). Conclusion AI-CS single-shot cine demonstrated greater image quality and clinical feasibility compared with bFFSP cine in healthy participants and participants with suspected arrhythmias. Keywords: Artificial Intelligence-assisted Compressed SENSE, Arrhythmias, Left Ventricular Structure, Left Ventricular Function, Cardiac MRI, Balanced Steady-State Free Precession Cine Sequences Supplemental material is available for this article. © RSNA, 2026.
引用
- Zhang N, Du F, Chen C, et al. Feasibility of Free-breathing Deep Learning-reconstructed Single-Shot Cine MRI in Participants with Arrhythmia: Comparison with Conventional Segmented Cine MRI. Radiol Cardiothorac Imaging. 2026. PMID: 41885622. doi:10.1148/ryct.250298
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。