文献速递神经技术与安全MRCT

低场便携式MRI在神经外科ICU机械通气患者中的应用:单中心回顾性分析

Utility of Low-Field Portable MRI in Neurosurgical ICU Patients Who Are Mechanically Ventilated: A Single-Center Retrospective Analysis.
PubMed 文献 · AJNR Am J Neuroradiol · 2026-03-04

本研究回顾性纳入2022年12月至2024年7月神经外科ICU内接受低场便携式MRI(0.23T)检查的机械通气患者,共50例患者60次检查,无不良事件。低场便携式MRI对急性脑损伤检出敏感度达96.7%,对梗死检测敏感度92.3%、特异度85.7%,38%的病例据此改变了治疗决策。

要点

  • 低场便携式MRI对机械通气神经外科ICU患者急性脑损伤检出敏感度96.7%,以缺血性梗死为主(48.3%)。
  • 对梗死检测敏感度92.3%(95%CI 64.0-99.8)、特异度85.7%(95%CI 42.1-99.6)。
  • 较CT检出更多术后梗死(14处 vs 2处),但准备时间更长(8.8 vs 5.6分钟,P<.05)。

核心结论

  • 低场便携式MRI是机械通气患者床旁神经监测可行且安全的技术,对危重脑异常的检出能力使其可能成为神经外科ICU中常规MRI的有价值补充。

研究设计与样本

  • 单中心回顾性研究,纳入2022年12月至2024年7月神经外科ICU内所有接受低场便携式MRI的机械通气患者,共50例患者60次检查,使用获中国国家药品监督管理局批准的0.23T低场便携式MRI设备,成像参数与患者准备方案标准化,由两名资深神经外科重症医师和一名盲法独立神经放射科医师分析图像。

关键影像表现/征象

  • 低场便携式MRI在96.7%的病例中识别出急性脑损伤,以缺血性梗死为主(48.3%),其次为颅内出血(21.7%)和感染(8.3%)。
  • 与CT相比,低场便携式MRI对术后梗死的检出敏感度更高(14处 vs 2处),但准备时间更长(8.8 vs 5.6分钟,P<.05)。

诊断标准与关键数值

  • 低场便携式MRI对梗死检测的敏感度为92.3%(95%CI 64.0-99.8),特异度为85.7%(95%CI 42.1-99.6)。
  • 低场便携式MRI对急性脑损伤的检出率为96.7%。

临床应用与阅片要点

  • 低场便携式MRI可在床旁对机械通气神经外科ICU患者进行影像监测,未见不良事件报告。
  • 低场便携式MRI发现使38%的病例治疗决策发生改变,促使手术干预或治疗调整。

局限性

  • 原文为单中心回顾性研究。
  • 原文指出未来研究应集中于提高图像质量和拓宽诊断应用。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Conventional MRI is frequently inaccessible to neurosurgical patients who are critically ill, especially those on mechanical ventilation, because of stringent safety requirements and high-shielding needs. Low-field portable MRI presents a promising alternative by enabling bedside imaging. Nonetheless, its clinical effectiveness and diagnostic precision in these patients require further investigation.

MATERIALS AND METHODS: This retrospective, single-center study included all patients who are mechanically ventilated who underwent low-field portable MRI between December 2022 and July 2024 in the neurosurgical intensive care unit. Utilizing a 0.23T low-field portable MRI (LF-pMRI) device approved by the National Medical Products Administration of China, imaging parameters and patient preparation protocols were standardized. Two senior neurosurgical intensivists and a blinded, independent neuroradiologist analyzed the MRI scans.

RESULTS: Over a 20 months, 60 LF-pMRI examinations were performed on 50 patients who are mechanically ventilated, with no adverse events reported. The cohort consisted of 26 women and 24 men, with a mean age of 49.2 ± 18.7 years. LF-pMRI exhibited high sensitivity, identifying acute brain injuries in 96.7% of cases, predominantly ischemic infarctions (48.3%), followed by intracranial hemorrhage (21.7%) and infections (8.3%). Compared with CT, LF-pMRI showed superior sensitivity for postoperative infarctions (14 versus 2 detections) despite longer preparation (8.8 versus 5.6 minutes, P < .05). The system achieved 92.3% sensitivity (95% CI: 64.0-99.8) and 85.7% specificity (95% CI: 42.1-99.6) for infarction detection. LF-pMRI findings directly altered management in 38% of cases, prompting surgical interventions or therapy adjustments.

CONCLUSIONS: LF-pMRI serves as a feasible and secure technique for bedside neuromonitoring in patients who are mechanically ventilated. Its proficiency in detecting critical brain abnormalities underscores its potential as a valuable complement to conventional MRI in the neurosurgical intensive care unit. Future research should concentrate on enhancing image quality and broadening its diagnostic applications.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Rao W, Mao JL, Huang-Fu LK, et al. Utility of Low-Field Portable MRI in Neurosurgical ICU Patients Who Are Mechanically Ventilated: A Single-Center Retrospective Analysis. AJNR Am J Neuroradiol. 2026. PMID: 41781174. doi:10.3174/ajnr.A9063

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。