产前胎儿超声心动图、心脏磁共振成像及急性母体高氧对预测胎儿右型大动脉转位新生儿急诊球囊房间隔造口术紧迫性的作用
前瞻性单中心队列研究纳入34例右型大动脉转位(TGA)胎儿,于34-38周行胎儿超声心动图和心脏磁共振(CMR),评估室内空气(RA)及急性母体高氧(AMH)下影像特征与新生儿急诊球囊房间隔造口术(BAS)的关系。结果显示RA下房间隔瓣形态异常、AMH下有效卵圆孔尺寸≤3.4 mm、动脉导管舒张期血流受限或持续反向及CMR示AMH下升主动脉/主肺动脉血氧饱和度比值>1与急诊BAS显著相关。
要点
- RA下房间隔瓣形态异常、AMH下有效卵圆孔≤3.4 mm及动脉导管血流异常是急诊BAS的最显著预测因素。
- CMR示AMH下升主动脉/主肺动脉血氧饱和度比值>1的胎儿产后急诊BAS风险显著增高(OR 28.6)。
- 34例中23例(68%)行新生儿BAS,其中12例因持续导管前血氧饱和度<70%于生后3小时内急诊BAS。
核心结论
- 在TGA胎儿中,产前评估RA下房间隔形态以及AMH下有效卵圆孔大小、动脉导管血流模式和升主动脉/主肺动脉血氧饱和度比值>1是预测新生儿急诊BAS需求最有用的变量。
研究设计与样本
- 前瞻性单中心队列研究,纳入34例TGA胎儿(室间隔完整29例,室间隔缺损≤4 mm 5例),于34-38周妊娠同时行胎儿超声心动图和(若可行)CMR,CMR用于量化胎儿体重、脑容量和血管血氧饱和度,产后收集导管前血氧饱和度和BAS需求及时机。
关键影像表现/征象
- RA下房间隔瓣形态异常与急诊新生儿BAS相关(P=0.004)。
- AMH下有效卵圆孔尺寸≤3.4 mm与急诊新生儿BAS相关(P=0.0024)。
- AMH下动脉导管舒张期血流受限或持续反向与急诊新生儿BAS相关(P=0.0006)。
- CMR示AMH下升主动脉/主肺动脉血氧饱和度比值>1的胎儿产后急诊BAS风险显著增高(OR 28.6,95%CI 1.1-620.3;P=0.0084)。
诊断标准与关键数值
- 急诊BAS定义为生后3小时内因持续导管前血氧饱和度<70%需行球囊房间隔造口术。
- AMH下有效卵圆孔尺寸≤3.4 mm预测急诊BAS(P=0.0024)。
- AMH下升主动脉/主肺动脉血氧饱和度比值>1预测急诊BAS的OR为28.6(95%CI 1.1-620.3;P=0.0084)。
临床应用与阅片要点
- 产前可联合胎儿超声心动图和CMR评估RA及AMH下房间隔形态、卵圆孔有效尺寸、动脉导管血流及升主动脉/主肺动脉血氧饱和度比值,以识别可能需要生后3小时内急诊BAS的新生儿。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Newborns with dextro-transposition of the great arteries (TGA) without adequate intracardiac shunting of oxygenated blood are at imminent risk of severe hypoxia at birth. Using fetal echocardiography and cardiac magnetic resonance imaging (CMR) in room air (RA) and during acute maternal hyperoxygenation (AMH), we sought to identify predelivery imaging features predictive of neonatal hypoxia and the need for urgent balloon atrial septostomy (BAS) within the first 3 h after birth.
METHODS: This was a prospective single-center cohort study of pregnancies with TGA with an intact ventricular septum (IVS) or a single ventricular septal defect (VSD) ≤ 4 mm. Fetal echocardiography and, if feasible, CMR were conducted concurrently at 34-38 weeks' gestation. Cardiac structures, including the foramen ovale (FO) and atrial septum, were examined using two-dimensional and Doppler echocardiography. CMR was used to quantify fetal weight, brain volume and vascular oxygen saturation (SaO2). Both imaging modalities were used to assess fetal vascular blood flows in RA and during AMH. Postnatal data collected included preductal oxygen saturation (SpO2) and the need for and timing of BAS. Univariable logistic regression analysis was used to evaluate associations between predelivery imaging features and the need for urgent neonatal BAS.
RESULTS: Of 34 newborns with TGA/IVS (n = 29) or TGA/VSD (n = 5), 23 (68%) underwent neonatal BAS, including 12 cases of urgent BAS < 3 h after birth for persistent preductal SpO2 < 70%. A fetal echocardiogram was obtained in all cases, while 26/34 (76%) underwent CMR, including 9/12 (75%) cases that underwent urgent BAS. On univariable logistic regression analysis, abnormal atrial septal flap morphology in RA (P = 0.004), effective FO size ≤ 3.4 mm during AMH (P = 0.0024) and constricted or continuously reversed diastolic flow across the ductus arteriosus (DA) during AMH (P = 0.0006) were the most significant predictors of urgent neonatal BAS. On CMR, fetuses with an ascending aorta (AAo)/main pulmonary artery (MPA) SaO2 ratio > 1 during AMH were significantly more likely to undergo urgent BAS postnatally (odds ratio, 28.6 (95% CI, 1.1-620.3); P = 0.0084).
CONCLUSION: In fetuses with TGA, predelivery assessment of atrial septal morphology in RA, as well as effective FO size, DA flow pattern and AAo/MPA SaO2 ratio > 1 during AMH, are the most useful variables for predicting the need for urgent neonatal BAS. © 2026 International Society of Ultrasound in Obstetrics and Gynecology.
引用
- Jaeggi E, Sun L, Saito M, et al. Role of predelivery fetal echocardiography, cardiac magnetic resonance imaging and acute maternal hyperoxygenation in predicting urgency of neonatal balloon atrial septostomy in fetal dextro-transposition of the great arteries. Ultrasound Obstet Gynecol. 2026. PMID: 41784038. doi:10.1002/uog.70200
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。