用于抽吸取栓的空心圆柱形换能器内血栓的组织碎化术研究
本研究将猪血凝块置于径向极化空心圆柱形换能器(内径2.5 mm、外径3.3 mm、长2.5 mm、PZT材料)腔内,以厚度模式6.1 MHz激励,观察不同脉冲长度、脉冲重复频率和治疗时间下气泡云与病灶形成,证实可形成液化区,病灶体积高度依赖暴露方案,支持该组织碎化术用于抽吸取栓的可行性。
要点
- 空心圆柱形换能器内可对血栓行组织碎化术并形成液化区。
- 病灶可在0.1秒内沿换能器中心轴形成,并随治疗时间延长而增大。
- 病灶体积高度依赖暴露方案,最大体积见于10微秒脉冲长度、1000 Hz脉冲重复频率方案。
核心结论
- 结果支持在可安装于抽吸式导管尖端的空心圆柱形换能器内对血栓行组织碎化术的可行性。
研究设计与样本
- 体外实验研究:将回缩的猪血凝块置于径向极化空心圆柱形换能器(内径2.5 mm、外径3.3 mm、长2.5 mm、PZT材料)腔内,以厚度模式6.1 MHz激励,变量为脉冲长度(10、20和100微秒)、脉冲重复频率(100、500和1000 Hz)和治疗时间(0.1-10.0秒)。
关键影像表现/征象
- 剖开的处理血凝块证实形成液化区。
- 病灶可在0.1秒内沿换能器中心轴形成,并随治疗时间延长在直径和长度上增大。
- 高频超声检查(二维)用于监测治疗中气泡云和病灶形成,(三维)用于量化治疗后病灶体积。
诊断标准与关键数值
- 病灶体积高度依赖暴露方案(每组n=5),最大体积见于10微秒脉冲长度、1000 Hz脉冲重复频率方案。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Thrombotic occlusions in the setting of stroke, pulmonary embolism and the peripheral vasculature are increasingly being treated with catheter-based aspiration approaches. Unfortunately, aspiration is frequently unsuccessful in extracting more challenging blood clots, which can become corked in the distal tip. In this study, we investigated the feasibility of using histotripsy to mechanically degrade thrombus within the lumen of a hollow cylindrical transducer (HCT), with a view to ultimately using this approach to improve aspiration thrombectomy procedures.
METHODS: Retracted porcine blood clots were situated within the lumen of a radially polarized HCT (2.5/3.3 mm inner/outer diameter, 2.5 mm length, PZT). The HCT was stimulated in thickness mode (6.1 MHz) as a function of pulse length (10, 20 and 100 µs), pulse repetition frequency (100, 500 and 1000 Hz) and treatment time (0.1-10.0 seconds). High-frequency ultrasound examination was used to monitor bubble clouds and lesion formation during treatments (2-D) and quantify post-treatment lesion volumes (3-D).
RESULTS: Bisected treated clots confirmed the formation of liquified zones. Lesions could form within 0.1 seconds along the central axis of the transducer and then grow in diameter and length with increasing treatment time. The lesion volume was highly dependent on the exposure scheme (n = 5/group), with the largest volume associated with the 10 µs pulse length 1000 Hz pulse repetition frequency scheme.
CONCLUSION: Collectively, these results support the feasibility of performing histotripsy on clots situated within an HCT compatible with mounting in the tip of an aspiration format catheter.