用非对比头颈主动脉血管壁MRI评估卒中患者心上动脉粥样硬化
研究开发了约15分钟扫描时间的非对比头颈主动脉血管壁MRI方案,并与主动脉上段CTA比较。108例急性缺血性卒中或短暂性脑缺血发作参与者中,血管壁MRI斑块检出率81.5%高于CTA的69.4%(P=.002),并将ESUS比例从35.2%降至20.4%(P<.001)。
要点
- 血管壁MRI斑块检出率81.5%(88/108)高于CTA的69.4%(75/108),P=.002。
- 血管壁MRI检出斑块内出血30/108(27.8%),钙化检测准确率91%(98/108)。
- 38例CTA判为ESUS者中血管壁MRI重分类16例,ESUS比例由35.2%降至20.4%(P<.001)。
核心结论
- 该头颈主动脉血管壁MRI方案可行,斑块检出率高于主动脉上段CTA,并有助于识别ESUS的病因。
研究设计与样本
- 研究开发了整合神经网络加速与多通道线圈的非对比头颈主动脉血管壁MRI方案,扫描时间约15分钟。
诊断标准与关键数值
- 以CTA为参考标准,血管壁MRI检测钙化的准确率为91%(98/108)。
- 血管壁MRI检出斑块内出血30/108(27.8%),溃疡检出率与CTA相当(28/108[25.9%]vs 25/108[23.1%],P=.51)。
- CTA识别49例血管狭窄,血管壁MRI识别47例病因,包括动脉粥样硬化41例、血栓3例、夹层3例。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Supracardiac atherosclerosis is a major cause of stroke. Although vessel wall MRI (vwMRI) can assess plaques, current techniques lack full head-neck-aortic arch coverage and efficiency. Purpose To develop and evaluate a head-neck-aortic vwMRI protocol for supracardiac atherosclerosis, compare its performance with that of supra-aortic CT angiography (CTA), and determine its feasibility in helping identify causes of embolic stroke of undetermined source (ESUS). Materials and Methods We developed a noncontrast head-neck-aortic vwMRI protocol integrated with neural network-based acceleration and multichannel coils, enabling a scan time of approximately 15 minutes. Then, participants with acute ischemic stroke or transient ischemic attack were recruited from October 2024 to March 2025. They received routine supra-aortic CTA and this new vwMRI protocol. Plaque vulnerabilities, vascular stenosis, and stroke etiologies were compared between the modalities. The accuracy of vwMRI for detecting calcification was evaluated using CTA as the reference standard, and the McNemar test was used to compare the findings between CTA and vwMRI. Results Among 108 participants who underwent imaging with both modalities (mean age, 56 years ± 14 [SD]; 89 male participants), the plaque detection rate was higher with vwMRI than CTA (88 of 108 participants [81.5%] vs 75 of 108 participants [69.4%]; P = .002). Moreover, vwMRI helped achieve 91% (98 of 108 participants) accuracy for calcification detection. vwMRI helped identify intraplaque hemorrhage in 27.8% (30 of 108) of participants and demonstrated an ulceration rate comparable with that of CTA (28 of 108 participants [25.9%] vs 25 of 108 participants [23.1%]; P = .51). CTA helped identify 49 participants with vascular stenosis, whereas vwMRI helped identify 47 participants with causes including atherosclerosis (n = 41), thrombus (n = 3), and dissection (n = 3). For 38 participants initially classified with ESUS via CTA, vwMRI enabled reclassification of 16, reducing the percentage of participants with ESUS from 35.2% (38 of 108 participants) to 20.4% (22 of 108 participants) (P < .001). Conclusion This head-neck-aortic vwMRI protocol was feasible and demonstrated a higher plaque detection rate than supra-aortic CTA. © RSNA, 2026 Supplemental material is available for this article. See also the editorial by von Kummer in this issue.
引用
- Jiang Q, Zhang Z, Chen S, et al. Evaluation of Supracardiac Atherosclerosis in Stroke with a Noncontrast Head-Neck-Aortic Vessel Wall MRI. Radiology. 2026. PMID: 41842667. doi:10.1148/radiol.251586
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。