文献速递乳腺技术与安全MR

一种新型通用时空诊断模型:瘤内流出与瘤周流入用于乳腺肿瘤的鉴别与分层

A novel and general spatiotemporal diagnostic model: Intratumoral outflow and peritumoral inflow for the differentiation and stratification of breast tumor.
PubMed 文献 · Eur J Radiol · 2025-12-20

本研究基于动态对比增强MRI的时空信息构建瘤内流出与瘤周流入(IOPI)模型,量化血流灌注与微循环差异,并在两中心回顾性验证。训练集来自中心1,测试集来自中心2,共纳入159例患者(80例恶性、79例良性)。IOPI模型在训练集AUC为0.911,外部测试集AUC为0.802,显著优于传统指标及其他模型(p<0.05);联合模型在诊断和风险分层中表现良好。

要点

  • IOPI模型在外部测试集AUC为0.802,显著优于传统指标及其他血流动力学模型(p<0.05)。
  • BIRADS联合IOPI模型在训练集诊断恶性AUC最高达0.940,敏感度92.0%。
  • ADC联合IOPI模型在测试集AUC为0.878,准确率84.2%,特异度88.9%。

核心结论

  • IOPI模型凸显时空动力学信息在改善乳腺肿瘤诊断方面的额外潜力,整合时间与空间概念的联合模型在乳腺癌诊断和风险分层中表现出较强的诊断性能。

研究设计与样本

  • 两中心回顾性分析,共纳入159例患者(80例恶性、79例良性病变),均行动态对比增强MRI;训练集来自中心1,测试集来自中心2;提取常规动力学参数(PE和SER)及判读的MRI特征(ADC和BI-RADS),通过逻辑回归构建血流动力学模型(IOPI、IIO、PIO、IPIO)和联合模型(ADC+IOPI、BIRADS+IOPI)。

诊断标准与关键数值

  • 训练集中IOPI模型AUC为0.911,特异度95.1%,敏感度82.0%,准确率89.5%。
  • 外部测试集中IOPI模型AUC为0.802,显著优于传统指标及其他模型(p<0.05)。
  • 训练集中BIRADS联合IOPI模型诊断恶性性能最高,AUC为0.940,敏感度92.0%。
  • 测试集中ADC联合IOPI模型诊断性能最高,AUC为0.878,准确率84.2%,特异度88.9%。
  • 联合模型在浸润分级分层和预测Ki-67表达方面表现相当,ADC联合IOPI特异度达90.9%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: A novel Intratumoral Outflow and Peritumoral Inflow (IOPI) model based on spatiotemporal information was developed to quantify differences in blood perfusion and microcirculation. Its performance was compared with conventional indicators, and its clinical application for diagnosing benign and malignant breast tumors, as well as its potential for risk stratification, was validated in a two-center study.

MATERIALS AND METHODS: A retrospective analysis of 159 patients (80 malignant and 79 benign lesions) undergoing dynamic contrast-enhanced MRI was conducted. Training set was from Center 1, testing set was from Center 2. Conventional kinetic parameters (PE and SER) and interpreted MRI features (ADC and BI-RADS) were extracted. Hemodynamics models (IOPI, IIO, PIO and IPIO) and combined models (ADC + IOPI, BIRADS + IOPI) were constructed by logistic regression. Classification performance was assessed by AUC, sensitivity, specificity and accuracy.

RESULTS: In the training cohort, the proposed IOPI model achieved an AUC of 0.911, with specificity of 95.1 %, sensitivity of 82.0 % and accuracy of 89.5 %. In external testing cohort, the AUC was 0.802, significantly outperformed conven tional indicators and others models (p < 0.05). The BIRADS combined IOPI model achieved the highest diagnostic performance in classifying malignancy of breast lesions, with the AUC values of 0.940 and sensitivity of 92.0 % in training cohort. In the testing cohort, the ADC combined IOPI model achieved the highest diagnostic performance with the AUC of 0.878, accuracy of 84.2 % and specificity of 88.9 %. The combined models also showed comparable performance in stratifying invasive grades and predicting Ki-67 expression (exceptional specificity of 90.9 % in ADC combined IOPI).

CONCLUSION: IOPI serves as a valuable tool that highlights the additional potential of spatiotemporal kinetic information for improving breast tumor diagnosis. The combined model which integrates time and spatial concepts, exhibited strong diagnostic performance for improved breast cancer diagnosis and risk stratification.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Meng Z, Zhou C, Xie H, et al. A novel and general spatiotemporal diagnostic model: Intratumoral outflow and peritumoral inflow for the differentiation and stratification of breast tumor. Eur J Radiol. 2025. PMID: 41616757. doi:10.1016/j.ejrad.2025.112622

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。