文献速递乳腺胸部心血管MR

乳腺癌放疗俯卧位与仰卧位长时间自主深吸气屏气期间危及器官稳定性的MRI分析

MRI-based analysis of organ at risk stability during prolonged voluntary deep inspiration breath-hold in prone and supine breast cancer radiotherapy.
PubMed 文献 · Br J Radiol · 2026-01-01

前瞻性观察性生理研究纳入10名健康女性志愿者,在俯卧位和仰卧位各完成2次2分8秒的长时间深吸气屏气,每16秒采集3D MRI评估心脏、肺及左乳位置稳定性。结果显示左乳位置稳定,但靠近乳腺的心脏部分随时间出现轻微进展性位移,俯卧位较仰卧位更明显;作者提出俯卧位3 mm、仰卧位2 mm的非对称心脏安全边界可能合适。

要点

  • 长时间深吸气屏气(2分8秒)在健康志愿者中可实现,左乳位置全程稳定。
  • 靠近乳腺的心脏部分在每次屏气中出现轻微但统计学显著的进展性位移,俯卧位比仰卧位更明显。
  • 为补偿上述微小位移,作者提出俯卧位3 mm、仰卧位2 mm的非对称心脏安全边界可能合适。

核心结论

  • 2分8秒的长时间深吸气屏气可实现,左乳位置稳定、邻近内部器官移动轻微;靠近乳腺的心脏部分出现小而进展性的位移,尤其在俯卧位。

研究设计与样本

  • 前瞻性观察性生理研究,10名健康女性志愿者,在俯卧位和仰卧位各完成2次长时间深吸气屏气(每次2分8秒),遵循经验证的过度通气和氧合方案,每次屏气期间每16秒采集连续3D MRI,共分析319个高质量3D MRI序列,采用累积距离-体积直方图评估器官空间关系并量化内部位移。

关键影像表现/征象

  • 累积距离-体积直方图显示各时间点和各次检查之间器官位置一致。
  • 左乳位置在所有长时间深吸气屏气全程保持稳定。
  • 每次长时间深吸气屏气期间均观察到轻微但统计学显著的心脏位移,且随时间增加,俯卧位比仰卧位更明显。

临床应用与阅片要点

  • 作者提出,为补偿长时间深吸气屏气期间的微小位移,俯卧位心脏非对称安全边界3 mm、仰卧位2 mm可能合适。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Deep inspiration breath-hold (DIBH) is commonly used in breast cancer radiotherapy to reduce radiation exposure to the heart and lungs. Recent techniques incorporating oxygen supplementation and hyperventilation have enabled DIBHs exceeding 2.5 minutes. However, data on internal organ stability during prolonged breath-holds (L-DIBH) remain limited.

METHODS: In this prospective observational physiological study, 10 healthy female volunteers performed 2 L-DIBHs (2 minutes 8 seconds each) in both prone and supine positions, following a validated hyperventilation and oxygenation protocol. Serial 3D MRI scans were acquired every 16 seconds during each L-DIBH to assess positional stability of the heart, lungs, and left-sided breast. Cumulative distance-volume histograms (cDiVHs) were used to evaluate spatial relationships between organs and quantify internal displacement over time.

RESULTS: A total of 319 high-quality 3D MRI series were analysed. cDiVHs demonstrated consistent organ positions across timepoints and sessions. While left breast position remained stable throughout all L-DIBHs, minor but statistically significant heart displacement was observed during each L-DIBH increasing over time, more pronounced in the prone position than supine.

CONCLUSIONS: L-DIBHs of 2 minutes and 8 seconds are achievable and demonstrate stability in left breast positioning, with minimal movement of adjacent internal organs. Small but progressive shifts of the portion of the heart nearest the breast were detected, particularly in prone positioning.

ADVANCES IN KNOWLEDGE: To account for these minimal displacements during L-DIBH, asymmetrical safety margins around the heart of 3 mm in prone and 2 mm in supine positions may be appropriate.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Huybrechts V, Vakaet V, De Noyette R, et al. MRI-based analysis of organ at risk stability during prolonged voluntary deep inspiration breath-hold in prone and supine breast cancer radiotherapy. Br J Radiol. 2026. PMID: 41577856. doi:10.1093/bjr/tqag018

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。