文献速递乳腺MR

超快动力学参数在鉴别转诊行MRI引导活检的可疑乳腺病变中的应用价值

Utility of ultrafast kinetic parameters in differentiation of suspicious breast lesions referred for MRI-guided biopsies.
PubMed 文献 · Clin Radiol · 2025-12-11

回顾性分析2023年6月至2025年5月一家三级转诊医院连续50例可疑乳腺病变(BI-RADS 4或5)的MRI引导活检,评估超快DCE-MRI动力学参数鉴别良恶性的诊断效能。恶性病变的最大斜率(MS)和初始曲线下面积(iAUC)更大,而对比剂到达时间(BAT)和强化时间(TTE)更短,各参数AUC为0.91至0.98。超快动力学参数能稳健区分转诊行MRI引导活检的可疑乳腺病变的良恶性。

要点

  • 在转诊行MRI引导活检的可疑乳腺病变中,恶性病变的MS和iAUC大于良性病变,BAT和TTE短于良性病变(均P<0.001)。
  • MS鉴别良恶性的AUC最高,为0.98(95%CI 0.95-1.00),其次为iAUC 0.94、TTE 0.93、BAT 0.91。
  • 本组50例活检中35例(70.0%)为良性、15例(30.0%)为恶性,包括2例由高危病变手术升级的癌。

核心结论

  • 超快动力学参数能稳健区分转诊行MRI引导活检的可疑乳腺病变的良恶性。

研究设计与样本

  • 回顾性分析2023年6月至2025年5月一家三级转诊医院连续50例可疑乳腺病变(BI-RADS 4或5)的MRI引导活检,采用3T MRI扫描仪于增强后第一分钟内获取高时间分辨率T1加权图像行超快DCE-MRI,获取MS、iAUC、BAT和TTE参数,以病理结果为参考标准。

诊断标准与关键数值

  • 恶性病变MS和iAUC大于良性病变(P<0.001),BAT和TTE短于良性病变(P<0.001);MS的AUC为0.98(95%CI 0.95-1.00),iAUC为0.94(95%CI 0.84-1.00),BAT为0.91(95%CI 0.80-0.98),TTE为0.93(95%CI 0.85-1.00)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To evaluate the diagnostic performance of ultrafast kinetic parameters in differentiating benign and malignancy lesions among suspicious breast lesions referred for MRI-guided biopsies.

MATERIALS AND METHODS: Consecutive MRI-guided biopsies of suspicious breast lesions (BI-RADS 4 or 5) in a tertiary referral hospital from June 2023 to May 2025 were retrospectively analyzed. Clinical information, procedural details and pathological results were retrieved. Pre-procedural standard and ultrafast dynamic contrast-enhanced magnetic resonance imaging (UF-DCE MRI) were reviewed. UF-DCE MRI consisted of high-temporal-resolution T1-weighted images obtained in the first minute using a 3T MRI scanner. Ultrafast kinetic parameters - maximum slope (MS), initial area-under-the-curve (iAUC), bolus arrival time (BAT) and time-to-enhancement (TTE) were acquired. Factors associated with benign and malignant breast lesions were assessed. Receiver operating characteristic curve analyses were performed.

RESULTS: Fifty MRI-guided breast biopsies were performed for 31 adult (≥18 years) female patients (median age: 61.0 (IQR 13.0) years). Thirty-five biopsies (70.0 %) were benign. Fifteen (30.0 %) were malignant, including two surgically upgraded carcinomas from high-risk lesions. In malignant lesions, MS (P<0.001) and iAUC (P<0.001) were larger, while BAT (P<0.001) and TTE (P<0.001) were shorter compared with benign lesions. Areas under the curve of MS (0.98, 95 % CI [0.95, 1.00], iAUC (0.94, 95 % CI [0.84, 1.00], BAT (0.91, 95 % CI [0.80, 0.98] and TTE (0.93, 95 % CI [0.85, 1.00]) were obtained.

CONCLUSION: Ultrafast kinetic parameters robustly distinguished between benignity and malignancy among suspicious breast lesions referred for MRI-guided biopsies.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Lam PL, Chan LY, Fenn D, et al. Utility of ultrafast kinetic parameters in differentiation of suspicious breast lesions referred for MRI-guided biopsies. Clin Radiol. 2025. PMID: 41520626. doi:10.1016/j.crad.2025.107212

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。