定量与半定量磁化传递MRI检测肾移植受者间质纤维化的比较
该横断面研究纳入20例移植后4至10年的肾移植受者与31名健康志愿者,比较3.0T下定量磁化传递(qMT)与600 Hz、1000 Hz偏频传统磁化传递成像(MTI)评估肾间质纤维化的效能及其对场强(1.5T与3.0T)的依赖性。结果显示3.0T下qMT指数f与MTI-MTR(600 Hz或1000 Hz)均能区分移植肾皮质与髓质纤维化,DWI与BOLD无差异;组织学皮质纤维化与3.0T的f-qMT直接相关,而与1.5T的f-qMT不相关。作者认为1.5T的MTI-600 Hz与3.0T的qMT均为有前景的无创评估移植肾纤维化工具。
要点
- 3.0T下qMT指数f与MTI-MTR(600 Hz或1000 Hz)均显示移植肾皮质与髓质纤维化高于健康志愿者。
- 3.0T下DWI与BOLD信号在移植肾与健康志愿者间无差异。
- 组织学皮质纤维化与3.0T的f-qMT直接相关,而与1.5T的f-qMT不相关。
核心结论
- 1.5T的MTI-600 Hz与3.0T的qMT均为有前景的无创评估移植肾纤维化工具,两者选择可能取决于设备可及性;其在1.5T与3.0T间的保真度可能通过允许比较不同MRI设备测量的肾纤维化而促进临床转化。
研究设计与样本
- 横断面研究,纳入20例肾移植后4至10年患者与31名健康志愿者;3.0T-MRI评估移植肾与健康志愿者肾的MTI、qMT、BOLD与DWI,1.5T-MRI评估移植肾纤维化的MTI与qMT;采用ELISA测定纤维化细胞因子,并评估移植肾活检样本的纤维化与细胞因子表达。
关键影像表现/征象
- 3.0T-MRI下qMT指数f与1000 Hz或600 Hz偏频MTI指数MTR均显示移植肾皮质与髓质纤维化高于健康志愿者。
- 3.0T-MRI下DWI与BOLD信号在移植肾与健康志愿者间无差异。
- 皮质与髓质MTI-MTR-600 Hz及f-qMT在1.5T与3.0T-MRI间可比,而MTI-MTR-1000 Hz在1.5T与3.0T-MRI间不可比。
- qMT与MTR的观察者间与观察者内可重复性在皮质与髓质均显示持续高可靠性。
诊断标准与关键数值
- 移植肾组织学皮质纤维化为11.12%(8.02,15.32),与3.0T-MRI的f-qMT直接相关(Spearman,P < 0.0001),与1.5T-MRI的f-qMT不相关。
- 组织学皮质纤维化与1.5T下600 Hz和1000 Hz的皮质及髓质MTR中度相关,而与3.0T-MRI下600 Hz和1000 Hz的皮质及髓质MTR不相关。
- f与移植后年数相关。
临床应用与阅片要点
- 3.0T下qMT指数f与MTI-MTR(600 Hz或1000 Hz)可用于区分移植肾皮质与髓质纤维化与健康志愿者。
- 1.5T下MTI-MTR-600 Hz及f-qMT与3.0T测量可比,MTI-MTR-1000 Hz在1.5T与3.0T间不可比。
- qMT与MTR在皮质与髓质的观察者间与观察者内可重复性均持续高。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To evaluate the efficacy of quantitative magnetization transfer (qMT) in quantifying interstitial fibrosis in kidney transplantation (KT) recipients, and to assess its dependence on MRI field strength (1.5T vs 3.0T), in comparison to conventional magnetization transfer imaging (MTI) performed at both 600 Hz and 1000 Hz offset frequencies.
MATERIALS AND METHODS: This cross-sectional study involved 20 patients, 4 to 10 years post-KT, and 31 healthy volunteers (HV). Using 3.0T-MRI, we assessed KT and HV kidneys using MTI, qMT, blood oxygenation-level-dependent (BOLD), and diffusion-weighted imaging (DWI), and at 1.5T-MRI, we also assessed in KT renal fibrosis with MTI and qMT. In addition, we measured fibrogenic cytokine levels in KT and HV using ELISA and assessed fibrosis and cytokine expression in KT biopsy samples.
RESULTS: KT showed renal dysfunction and higher circulating collagen-IV, MCP-1, IL-6, and NGAL than HV. At 3.0T-MRI, both the qMT index f and the MTI index magnetization-transfer ratio (MTR) measured at either 1000 Hz or 600 Hz demonstrated greater KT cortex and medulla fibrosis compared with HV, whereas DWI and BOLD signals showed no difference. Cortical and medullary MTI-MTR-600 Hz and f -qMT were comparable between 1.5T and 3.0T-MRI, whereas MTI-MTR-1000 Hz was not. Inter- and intra-observer reproducibility of qMT and MTR showed consistently high reliability across the cortex and medulla. Histologic cortical fibrosis in KT [11.12% (8.02, 15.32)] correlated directly with f -qMT at 3.0T-MRI (Spearman, P < 0.0001) but not at 1.5T-MRI, and correlated modestly with cortical and medullary MTR at 600 Hz and 1000 Hz at 1.5T but not at 3.0T-MRI. In addition, f correlated with years post-KT.
CONCLUSIONS: Both MTI-600 Hz at 1.5T-MRI and qMT at 3.0T-MRI are promising noninvasive tools for evaluating kidney allograft fibrosis, and the choice between them may depend on machine availability. Furthermore, their fidelity between 1.5T and 3.0T-MRI may facilitate clinical translation by affording comparison of renal fibrosis measured on different MRI machines.
引用
- Liu YF, Abdurakhimova DA, Al Saeedi M, et al. Comparison of Quantitative and Semiquantitative MT-MRI for Detection of Interstitial Fibrosis in Kidney Transplant Recipients. Invest Radiol. 2026. PMID: 41521503. doi:10.1097/RLI.0000000000001270
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。