超低剂量光子计数探测器CT用于肺气肿评估:与低剂量CT的头对头对比研究

Ultra-Low-Dose Photon-counting Detector CT for Emphysema Assessment: A Head-to-Head Comparative Study with Low-Dose CT.
PubMed 文献 · Radiology · 2026-01-01

前瞻性纳入152例肺气肿患者,同日行低剂量与超低剂量光子计数CT,超低剂量方案辐射剂量较标准低剂量降低87%(0.20 mSv vs 1.58 mSv),图像质量主观评分无显著差异但噪声评分更低,视觉与自动评估肺气肿的组间一致性极好。

要点

  • 超低剂量光子计数CT平均有效剂量0.20 mSv,较低剂量CT的1.58 mSv降低87%。
  • 两方案整体图像质量、锐利度、伪影评分无显著差异,超低剂量图像噪声评分更低。
  • 视觉评估小叶中央型与间隔旁型肺气肿严重程度一致性极好(加权κ分别为0.98、0.96)。

核心结论

  • 光子计数CT可在相当于两张胸部X线片的辐射剂量下,不损害图像质量地完成肺气肿的视觉与自动评估。

研究设计与样本

  • 前瞻性研究,纳入2024年11月至2025年2月同日行低剂量与超低剂量光子计数CT的肺气肿患者152例(中位年龄68岁,IQR 60-72岁;男性139例)。

关键影像表现/征象

  • 超低剂量与低剂量方案整体图像质量中位评分均为4分(IQR 4-5),差异无统计学意义(P = .16)。
  • 两方案锐利度中位评分均为4分(IQR 4-5),差异无统计学意义(P = .08)。
  • 两方案伪影中位评分均为4分(IQR 3-4),差异无统计学意义(P = .39)。
  • 超低剂量图像噪声评分中位3分(IQR 3-3),低于低剂量图像的4分(IQR 4-4),差异有统计学意义(P < .001)。

诊断标准与关键数值

  • 视觉评估小叶中央型肺气肿严重程度两方案间加权κ = 0.98。
  • 视觉评估间隔旁型肺气肿严重程度两方案间κ = 0.96。
  • 全肺及各肺叶低衰减容积测量两方案间组内相关系数范围0.96-0.98。
  • 视觉小叶中央型肺气肿严重程度分级与低衰减容积测量的一致性:低剂量方案加权κ = 0.73,超低剂量方案加权κ = 0.75。

临床应用与阅片要点

  • 超低剂量光子计数CT平均有效剂量0.20 mSv ± 0.03(SD),低剂量方案为1.58 mSv ± 0.39,超低剂量方案辐射暴露降低87%(P < .001)。
  • 自动低衰减容积分析在超低剂量与低剂量方案间一致性极好,可用于肺气肿定量随访。
  • 超低剂量图像噪声评分较低剂量图像更低(即噪声更多),但整体图像质量、锐利度与伪影无显著差异。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Reducing the radiation dose without compromising image quality or diagnostic accuracy is essential for repeat CT monitoring in emphysema. Purpose To evaluate the accuracy of ultra-low-dose (ULD) photon-counting CT (PCCT) for both visually and quantitatively assessing emphysema, and to compare this accuracy with that of low-dose (LD) PCCT. Materials and Methods Participants with emphysema who underwent same-day LD and ULD PCCT between November 2024 and February 2025 were prospectively included. Two radiologists independently evaluated the image quality parameters (overall image quality, sharpness, artifacts, and noise) and visually assessed emphysema (subtype and severity). Automated emphysema quantification was performed using low-attenuation volume (LAV) analysis. For centrilobular emphysema (CLE), automated LAV measurements were converted to severity grades and compared with visual severity grades. Paired t tests, Cohen κ analysis, and intraclass correlation coefficients were used to evaluate differences and agreement in findings at LD and ULD PCCT. Results In 152 participants (median age, 68 years [IQR, 60-72 years]; 139 male participants), the ULD protocol reduced radiation exposure by 87% compared with the LD protocol (mean effective dose, 0.20 mSv ± 0.03 [SD] vs 1.58 mSv ± 0.39; P < .001). There was no evidence of a difference between the two protocols in overall image quality (median score, 4 [IQR, 4-5] for both; P = .16), sharpness (median score, 4 [IQR, 4-5] for both; P = .08), or artifacts (median score, 4 [IQR, 3-4] for both; P = .39), but ULD images had lower noise scores (ie, more noise) than LD images (median score, 3 [IQR, 3-3] vs 4 [IQR, 4-4]; P < .001). There was excellent agreement between the two protocols for grading of visual CLE severity (weighted κ = 0.98) and paraseptal emphysema severity (κ = 0.96). The two protocols exhibited excellent agreement in LAV measurements across the lungs and for individual lung lobes (intraclass correlation coefficient range, 0.96-0.98). Visual CLE severity grades demonstrated good agreement with LAV measurements for both the LD (weighted κ = 0.73) and ULD (weighted κ = 0.75) protocols. Conclusion PCCT enables accurate visual and automated assessments of emphysema at a radiation dose equivalent to that of two chest radiographs without compromising image quality. © RSNA, 2026 Supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。