文献速递神经技术与安全CT

高螺距涡轮FLASH模式联合迭代线束硬化校正在颅脑CT中有助于显示急性小硬膜下血肿

A combination of High-Pitch turbo FLASH mode and iterative Beam-Hardening correction in cranial computed tomography Facilitates acute small subdural hematoma visualization.
PubMed 文献 · Eur J Radiol · 2025-12-13

研究比较FLASH与非FLASH颅脑CT在扫描时间、辐射剂量和运动伪影上的差异,并在FLASH图像上比较迭代线束硬化校正(iBHC)与非iBHC重建的伪影和对比度。结果显示FLASH组扫描时间、辐射剂量和运动伪影均显著降低,iBHC组颅下及后颅窝伪影严重程度分级显著更低,灰白质CNR及颅骨与硬膜下血肿间CNR和CT值差异率显著更高。

要点

  • FLASH模式较非FLASH模式显著降低扫描时间、辐射剂量和运动伪影。
  • FLASH扫描中iBHC较非iBHC显著降低颅下及后颅窝伪影严重程度分级(P < 0.001)。
  • iBHC组灰白质CNR及颅骨与硬膜下血肿间CNR和CT值差异率显著更高(P < 0.05)。

核心结论

  • FLASH扫描联合iBHC重建有效减少伪影、提高图像对比度并增强检测急性硬膜下血肿的诊断信心。

研究设计与样本

  • 研究纳入53例接受FLASH模式平扫CT的患者和46例接受非FLASH模式平扫CT的患者,比较两种技术的扫描时间、辐射剂量和运动伪影,并对FLASH图像应用iBHC与非iBHC重建方法进行比较。

关键影像表现/征象

  • FLASH组较非FLASH组扫描时间、辐射剂量和运动伪影显著降低。
  • FLASH扫描中iBHC组颅下和后颅窝伪影严重程度分级显著低于非iBHC组(P < 0.001)。
  • iBHC组灰质与白质间CNR以及颅骨与硬膜下血肿间CNR和CT值差异率显著高于非iBHC组(P < 0.05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To assess the impact of combined high-pitch turbo FLASH mode and iterative beam-hardening correction (iBHC) on image quality and diagnostic performance for detecting acute small subdural hematoma in brain CT.

MATERIALS AND METHODS: Fifty-three patients received unenhanced CT scans in FLASH mode, while forty-six patients received scans in non-FLASH mode. The scanning time, radiation dose, and motion artifacts were compared between the two techniques, and iBHC and non-iBHC reconstruction methods were applied to FLASH images. The severity of artifacts in the subcalvarial and posterior fossa was categorized into three grades for qualitative analysis. For quantitative analysis, CT values and standard deviations of gray matter, white matter, cerebrospinal fluid, the skull, and subdural hematoma were measured, and the contrast-to-noise ratio (CNR) and CT value difference rate were calculated. The differences in these parameters between the iBHC and non-iBHC groups were analyzed.

RESULTS: The FLASH group demonstrated significantly reduced scan time, radiation dose, and motion artifacts compared with the non-FLASH group. In the FLASH scanning mode, the iBHC group had significantly lower severity grades of subcalvarial and posterior fossa artifacts than the non-iBHC group (P < 0.001). Moreover, the CNR between the gray matter and white matter and the CNR and CT value difference rates between the skull and subdural hematoma were significantly higher in the iBHC group (P < 0.05).

CONCLUSION: The combination of FLASH scanning and iBHC reconstruction effectively reduced artifacts, improved image contrast, and enhanced diagnostic confidence for detecting acute subdural hematomas.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Zhang X, Ou Y, He Q, et al. A combination of High-Pitch turbo FLASH mode and iterative Beam-Hardening correction in cranial computed tomography Facilitates acute small subdural hematoma visualization. Eur J Radiol. 2025. PMID: 41494443. doi:10.1016/j.ejrad.2025.112611

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。