文献速递神经MR

C-DIR:脑MRI中具有受控伪影抑制的双反转恢复

C-DIR: Double Inversion Recovery with Controlled Artifact Suppression in Brain MRI.
PubMed 文献 · AJNR Am J Neuroradiol · 2026-07-01

本前瞻性研究在3T上对14名参与者采集DIR与C-DIR图像,C-DIR采用优化控制设计的反转脉冲以抵抗B0和射频场不均匀性。结果显示C-DIR减少伪影信号,灰质与脑脊液间CNR增加27%、脑干与邻近脑脊液间CNR增加102%,皮质灰质SNR在DIR为10.74±1.48、C-DIR为11.68±2.21(P=.07)。

要点

  • C-DIR通过优化控制反转脉冲抵抗B0和射频场不均匀性,减少伪影信号。
  • 灰质与脑脊液间CNR增加27%(P<.001),脑干与邻近脑脊液间CNR增加102%(P<.001)。
  • 皮质灰质SNR在DIR为10.74±1.48、C-DIR为11.68±2.21,差异未达统计学显著(P=.07)。

核心结论

  • 采用稳健射频脉冲的反转改善了DIR质量,表现为伪影减少和CNR提高。

研究设计与样本

  • 前瞻性研究,在3T采集DIR与C-DIR图像,纳入14名参与者(8名男性,年龄36.1±11.5岁),来自单一学术医学中心,招募时间为2024年10月至2025年8月;其中9名健康、2名复发缓解型MS、1名持续性脑震荡症状、2名无症状WM高信号。

关键影像表现/征象

  • C-DIR在B0和射频场存在不均匀性时表现出改善的反转,导致伪影信号被去除。
  • 由一名放射科医生独立视觉评估CSF抑制、伪影存在以及MS病灶和WM高信号的可见性。

诊断标准与关键数值

  • 在8名健康志愿者中计算SNR和CNR的均值与标准差,使用Student t检验评估显著性。
  • CNR增加范围从灰质与脑脊液间的27%(P<.001)到脑干与邻近脑脊液间的102%(P<.001)。
  • 皮质灰质SNR在DIR为10.74±1.48,在C-DIR为11.68±2.21(P=.07)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Double inversion recovery (DIR) is an MRI technique in which 2 types of tissue are suppressed, usually CSF and WM. The suppression is achieved with 2 inversion pulses before the acquisition of the imaging data. In the presence of strong inhomogeneities in the static magnetic field B0 and/or the radiofrequency (RF) field, inversion may be inadequate, resulting in bright signal in tissues that should have been suppressed. The purpose of this work was to develop a DIR scan with inversion pulses that are robust against inhomogeneities in the B0 and RF field.

MATERIALS AND METHODS: In this prospective study, the DIR sequence was equipped with inversion pulses designed with optimal control. Robustness against field inhomogeneities was incorporated into the cost functional for pulse optimization. DIR and controlled double inversion recovery (C-DIR) MR images were acquired at 3T in 14 participants (8 men, age = 36.1 ± 11.5 years) enrolled between October 2024 and August 2025 from a single academic medical center: 9 healthy; 2 with relapsing-remitting MS; 1 with persistent concussion symptoms; and 2 with asymptomatic WM hyperintensities. Suppression of CSF, presence of artifacts, and visibility of MS lesions and WM hyperintensities were independently assessed visually by a radiologist. In 8 healthy volunteers, means and SDs were computed for SNR and contrast-to-noise ratio (CNR), with significance evaluated using a Student t test.

RESULTS: C-DIR exhibits improved inversion in the presence of inhomogeneities in the B0 and the RF field, resulting in the removal of artifactual signal. CNR increases ranged from 27% between gray matter and CSF (P < .001) to 102% between the brainstem and adjacent CSF (P < .001). SNR in the cortical gray matter was 10.74 ± 1.48 in DIR and 11.68 ± 2.21 in C-DIR (P = .07).

CONCLUSIONS: Inversion with a robust RF pulse improves the quality of DIR, demonstrating artifact reduction and improved CNR. Controlled inversion in double inversion recovery reduces artifacts and increases contrast to noise ratio in brain MRI.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Jaffray A, Graf C, Rund A, et al. C-DIR: Double Inversion Recovery with Controlled Artifact Suppression in Brain MRI. AJNR Am J Neuroradiol. 2026. PMID: 41545309. doi:10.3174/ajnr.A9167

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。