指南与共识儿科影像胸部腹部CTDRUS

美国放射学会适宜性标准:儿童摄入或吸入异物

ACR Appropriateness Criteria® Ingested or Aspirated Foreign Body-Child.
指南 / 共识 · J Am Coll Radiol · 2026-01-01

儿童摄入或吸入异物是儿科急诊常见原因,本文件构建了三个临床情景。情景1疑似摄入或吸入异物初检时,颈胸腹盆腔X线通常适宜,高度怀疑透X线异物时低剂量非增强胸部CT也可能适宜。情景2疑似摄入异物而初检X线阴性时,非增强胸部CT通常适宜,透视食管造影或腹盆腔CT可能适宜,已知摄入水珠时腹部超声可能有帮助。情景3疑似吸入异物而初检X线阴性时,非增强胸部CT通常适宜,侧卧位胸片和透视检查通常不适宜。

要点

  • 疑似儿童摄入或吸入异物,颈胸腹盆腔X线通常适宜作为初始影像检查。
  • 高度怀疑透X线异物时,低剂量非增强胸部CT也可能适宜。
  • 初检X线阴性而疑似吸入异物时,非增强胸部CT通常适宜,侧卧位胸片和透视通常不适宜。

核心结论

  • 针对儿童摄入或吸入异物,文件按三个临床情景给出了初始及后续影像检查的适宜性推荐。

研究设计与样本

  • 美国放射学会适宜性标准,由多学科专家小组每年审查,采用GRADE等证据分级方法及RAND/UCLA适宜性方法,基于同行评议文献系统分析制定。

诊断标准与关键数值

  • 情景1(疑似摄入或吸入异物,初始影像):颈、胸、腹、盆腔X线通常适宜;高度怀疑透X线异物时低剂量非增强胸部CT也可能适宜。
  • 情景2(疑似摄入异物,初始X线阴性,下一步检查):非增强胸部CT通常适宜;透视食管造影或腹盆腔CT可能适宜;已知摄入水珠时腹部超声可能有帮助。
  • 情景3(疑似吸入异物,初始X线阴性,下一步检查):非增强胸部CT通常适宜;侧卧位胸片和透视检查通常不适宜。

临床应用与阅片要点

  • 儿童疑似摄入或吸入异物时,可首先行颈、胸、腹、盆腔X线定位异物。
  • X线阴性但高度怀疑透X线异物时,可考虑低剂量非增强胸部CT。
  • 疑似吸入异物而X线阴性时,可考虑非增强胸部CT,侧卧位胸片和透视通常不适宜。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Ingestion or aspiration of foreign bodies (FBs) is a common reason for pediatric emergency department visits. In this document, three variants were developed. In Variant 1 (suspect ingested or aspirated FB, initial imaging), neck, chest, abdomen, and pelvis radiographs are usually appropriate to identify the presence and location of a swallowed or inhaled FB. Low-dose noncontrast chest CT may also be appropriate when there is high suspicion for radiolucent FB. In Variant 2 (suspect ingested FB, initial radiographs negative, next imaging study), chest CT without contrast is usually appropriate, although fluoroscopic esophagram or CT abdomen and pelvis may be appropriate. If known ingested water beads, abdomen ultrasound may be helpful. In Variant 3 (suspect aspirated FB, initial radiographs negative, next imaging study), CT chest without contrast is usually appropriate while decubitus chest radiographs and fluoroscopy studies are usually not appropriate. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.

来源:J Am Coll Radiol,查看原文。版权归原作者所有。

引用

  1. Meyers ML, Moore MM, Baker JB, et al. ACR Appropriateness Criteria® Ingested or Aspirated Foreign Body-Child. J Am Coll Radiol. 2026. PMID: 41485865. doi:10.1016/j.jacr.2025.10.028

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。