文献速递骨肌技术与安全CT

从影像到干预:多中心验证的影像组学流程用于指导股骨颈骨折手术决策

From Imaging to Intervention: A Multicenter-Validated Radiomics Pipeline for Guiding Femoral Neck Fracture Surgical Management.
PubMed 文献 · Acad Radiol · 2025-12-01

本研究开发并评估股骨颈骨折(FNF)影像组学流程模型,用于诊断骨折稳定性并辅助手术决策。自动分割算法初步勾画CT显示的骨折移位区域后手动修正,基于影像组学特征构建逻辑回归模型生成Rad-score进行骨折稳定性分类,并输入下游模型指导手术决策。骨折稳定性模型内部和外部测试集AUC分别为0.905(95%CI 0.853-0.944)和0.821(95%CI 0.778-0.859);手术决策模型内部和外部测试集AUC分别为0.881(95%CI 0.810-0.932)和0.820(95%CI 0.757-0.873)。

要点

  • 骨折稳定性影像组学模型内部测试集AUC为0.905(95%CI 0.853-0.944)。
  • 骨折稳定性模型外部测试集AUC为0.821(95%CI 0.778-0.859)。
  • 手术决策模型内部和外部测试集AUC分别为0.881和0.820。

核心结论

  • 影像组学流程模型在33个中心的测试集中对骨折稳定性分类和辅助手术决策表现出稳健性能,模型纳入可解释人工智能进行骨折量化分析,支持医生做出客观临床决策。

研究设计与样本

  • 研究纳入确诊FNF患者,采用自动分割算法初步勾画CT显示的骨折移位区域后手动修正,基于所选影像组学特征训练逻辑回归模型生成Rad-score进行骨折稳定性分类,并输入下游模型指导手术决策,使用多中心数据进行内部和外部验证评估流程模型的泛化性。骨折稳定性和手术决策内部数据集分别包括624例和410例患者,外部测试集分别包括来自32个中心的364例和186例患者。

诊断标准与关键数值

  • 骨折稳定性影像组学模型内部测试集AUC为0.905(95%CI 0.853-0.944)。
  • 骨折稳定性影像组学模型外部测试集AUC为0.821(95%CI 0.778-0.859)。
  • 手术决策模型内部测试集AUC为0.881(95%CI 0.810-0.932)。
  • 手术决策模型外部测试集AUC为0.820(95%CI 0.757-0.873)。

临床应用与阅片要点

  • 作者认为模型纳入可解释人工智能进行骨折量化分析,支持医生做出客观临床决策。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To develop and evaluate a femoral neck fracture (FNF) pipeline model for diagnosing fracture stability and aiding surgical decision-making.

MATERIALS AND METHODS: Patients with confirmed FNFs were enrolled in the study. An automatic segmentation algorithm was employed to initially delineate fracture-displaced regions revealed using CT images, with subsequent manual refinement. A logistic-regression model was first trained on selected radiomic features to generate a Rad-score for fracture-stability classification. The Rad_score was then fed into a downstream model to guide surgical decision-making. The internal and external validation with multi-center data were used to assess the generalizability of the pipeline model.

RESULTS: The internal dataset for fracture stability and surgical decision-making included 624 and 410 patients, respectively. The corresponding external test sets, included 364 and 186 patients enrolled from 32 centers. The radiomics model for FNF stability exhibited robust performance, achieving an area under the curve (AUC) of 0.905 (95% confidence interval [CI]: 0.853-0.944) and 0.821 (95% CI: 0.778-0.859) for the internal and external test sets, respectively. The AUCs for the surgical decision-making models were 0.881 (95% CI: 0.810-0.932) and 0.820 (95% CI: 0.757-0.873) for the internal and external test sets, respectively.

CONCLUSION: The radiomics pipeline model exhibited robust performance in classifying fracture stability and aiding surgical decision-making in the test sets across 33 centers. Our model incorporates explainable artificial intelligence in fracture quantification analysis, supporting doctors in making objective clinical decisions.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Mu L, Liu Y, Xie Y, et al. From Imaging to Intervention: A Multicenter-Validated Radiomics Pipeline for Guiding Femoral Neck Fracture Surgical Management. Acad Radiol. 2025. PMID: 41330790. doi:10.1016/j.acra.2025.11.024

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。