光子计数探测器CT血管造影对豆纹动脉的可视化:一项回顾性队列研究
回顾性纳入159例蛛网膜下腔出血患者,比较光子计数探测器CT(PCD-CT)、能量积分探测器CT血管造影(EID-CTA)与DSA对豆纹动脉(LSA)的显示。距大脑中动脉起始部5 mm以内,PCD-CT与DSA在LSA检出和长度上无差异;超过5 mm处DSA测得的LSA长度显著更长。PCD-CT在LSA检出和长度测量上优于EID-CTA,观察者间一致性为差至中等。
要点
- 距大脑中动脉起始部5 mm以内,PCD-CT与DSA在豆纹动脉检出和长度上无差异。
- 距大脑中动脉起始部超过5 mm处,DSA测得的豆纹动脉长度显著长于PCD-CT。
- PCD-CT对豆纹动脉的检出和长度测量均优于EID-CTA。
核心结论
- PCD-CT有望作为无创豆纹动脉可视化方法,尚需在前瞻性研究和临床环境中进一步评估。
研究设计与样本
- 回顾性队列研究,纳入2021至2024年接受DSA并同期行EID-CTA或PCD-CT的成人蛛网膜下腔出血患者159例,PCD-CT采用超高分辨率(UHR)模式采集,以DSA为参照。
诊断标准与关键数值
- 距大脑中动脉起始部5 mm以内评估全部豆纹动脉分支;超过5 mm处仅测量最大分支的长度。
- 距大脑中动脉起始部5 mm以内,PCD-CT与DSA在豆纹动脉检出和长度上无差异。
- 距大脑中动脉起始部超过5 mm处,DSA测得的豆纹动脉长度显著长于PCD-CT。
- PCD-CT在豆纹动脉检出和长度测量上优于EID-CTA。
- 观察者1对PCD-CT图像质量评分低于DSA,观察者2认为两者无差异;EID-CTA图像质量显著低于PCD-CT和DSA;各模态观察者间一致性为差至中等。
局限性
- 原文结论指出PCD-CT尚需在前瞻性研究和临床环境中进一步评估。
- 各模态观察者间一致性仅为差至中等。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The visualisation of lenticulostriate arteries (LSA) using CT-techniques has not been extensively studied. Currently, digital subtraction angiography (DSA) is the preferred imaging modality for LSA visualisation. The new photon-counting detector CT (PCD-CT) may offer a non-invasive alternative. This study evaluates PCD-CT for LSA visualisation compared to DSA and energy-integrating detector CT-angiography (EID-CTA).
METHODS: We assessed imaging data from subarachnoid haemorrhage (SAH) patients, as they are expected to have intact LSA and routinely undergo DSA. From 2021 to 2024, adult SAH-patients who underwent both DSA and either EID-CTA or PCD-CT were enrolled. PCD-CT was acquired in UHR mode. For LSA > 5 mm from the middle cerebral artery (MCA) origin, only the length of the largest branch was measured, whereas for LSA < 5 mm all individual branches were assessed. LSA presence, length and subjective image quality were assessed across PCD-CT, EID-CTA, and DSA by two radiologists. Cohen's kappa and the Intraclass Correlation Coefficient were used to evaluate inter-rater agreement.
RESULTS: 159 patients were included. No differences were found between DSA and PCD-CT in LSA detection and length < 5 mm from the MCA origin. At > 5 mm from the MCA origin, the measured length of LSA was significantly longer on DSA. PCD-CT outperformed EID-CTA for LSA detection and length measurements. Observer 1 rated PCD-CT quality lower than DSA, while observer 2 found no difference. EID-CTA quality was rated significantly lower than both PCD-CT and DSA. Inter-rater agreement ranged from poor to moderate across modalities.
CONCLUSION: PCD-CT holds promise as a method for non-invasive LSA visualisation and requires further evaluation in prospective studies and clinical settings.
引用
- Huijberts I, Wagemans BAJM, Pinckaers FME, et al. Visualisation of lenticulostriate arteries using photon counting detector CT angiography: A retrospective cohort study. Eur J Radiol. 2025. PMID: 41418690. doi:10.1016/j.ejrad.2025.112618
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。