外周动静脉畸形大量弹簧圈栓塞后CT血管成像中金属伪影减少技术的应用价值
这项前瞻性单中心研究纳入30例接受弹簧圈栓塞的外周动静脉畸形患者,采用双能CT行栓塞后CT血管成像,在50和70 keV下分别以FBP、AR50和DL-M重建并经SMAR处理,以未经SMAR的DL-M为基线。结果显示SMAR处理图像的SD和AI显著低于基线(均p<0.001),主观伪影减少和邻近血管显示评分也显著改善(p<0.001),三种SMAR处理方法间无显著差异;3例出现新伪影但对判读影响轻微。
要点
- 弹簧圈栓塞后CT血管成像经SMAR处理可显著降低金属伪影(SD、AI均p<0.001)。
- SMAR处理显著改善邻近血管显示的主观评分(p<0.001)。
- FBP、AR50与DL-M三种重建经SMAR处理后图像质量无显著差异。
核心结论
- 经SMAR处理的FBP、AR50和DL-M重建可显著减少外周动静脉畸形弹簧圈栓塞后的金属伪影并改善血管显示,支持其用于治疗后评估和临床决策。
研究设计与样本
- 前瞻性单中心研究,纳入30例因动静脉畸形接受弹簧圈栓塞的患者,栓塞后采用双能CT行CT血管成像,于50和70 keV下分别以FBP、AR50和DL-M重建并经SMAR处理,以未经SMAR的DL-M为基线,由一名住院医师和一名主治放射科医师进行主观评分。
关键影像表现/征象
- 在两种能量水平下,SMAR处理图像的SD和AI平均值均显著低于基线DL-M(均p<0.001)。
- 伪影减少和邻近血管显示的主观评分显著改善(p<0.001)。
- 三种SMAR处理方法之间无显著差异。
- 3例出现新伪影,但对可判读性影响轻微。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the image quality of three reconstruction methods-filtered back projection (FBP), adaptive statistical iterative reconstruction (AR50), and deep learning-based reconstruction (DL-M)-processed with the Smart Metal Artifact Reduction (SMAR) technique for post-embolization assessment of peripheral arteriovenous malformations (AVMs).
MATERIALS AND METHODS: In this prospective single-center study, 30 patients who underwent coil embolization for AVM were included. Post-embolization CT angiography was performed using dual-energy CT. Virtual monoenergetic images at 50 and 70 keV were reconstructed using FBP, AR50, and DL-M. All were processed with SMAR, and DL-M without SMAR served as the baseline. Artifact severity was objectively assessed using the standard deviation (SD) around the AVM, artifact index (AI), and contrast-to-noise ratio (CNR). Two readers (a resident and a staff radiologist) subjectively graded artifact severity, vessel visualization, and new artifacts using 4-point scales.
RESULTS: At both energy levels, average SD and AI were significantly lower in SMAR-processed images than in baseline DL-M (all p < 0.001). Subjective scores for artifact reduction and visualization of adjacent vessels were also significantly improved (p < 0.001). There were no significant differences among the three SMAR-processed methods. New artifacts appeared in three cases but had minimal effect on interpretability.
CONCLUSIONS: SMAR-processed FBP, AR50, and DL-M reconstructions significantly reduced metal artifacts and improved visualization after AVM coil embolization, supporting their value for post-treatment evaluation and clinical decision-making.