文献速递骨肌MR

GRAPPATINI合成T2加权成像及T2定量用于肩关节评估:与传统T2加权成像的比较

Synthetic T2-weighted images and T2 quantification using GRAPPATINI for shoulder joint evaluation: comparison with conventional T2-weighted images.
PubMed 文献 · Skeletal Radiol · 2025-12-16

回顾性纳入23例(3男20女,中位年龄62岁)行3.0 T肩关节MRI者,比较GRAPPATINI合成脂肪饱和T2WI与传统脂肪饱和T2WI对冈上肌腱及上盂唇病变的检出等效性,并分析合成T2值与盂肱关节软骨退变的相关性。结果显示两种序列对冈上肌腱和上盂唇病变的检出可互换,且退变软骨的T2值显著高于非退变软骨。

要点

  • GRAPPATINI合成fs-T2WI与传统fs-T2WI对冈上肌腱和上盂唇病变的检出具有可互换性。
  • 合成T2-mapping可在形态学评估外补充软骨退变的定量信息。
  • 盂肱关节退变软骨的T2值显著高于非退变软骨。

核心结论

  • GRAPPATINI合成fs-T2WI评估冈上肌腱和上盂唇病变时诊断等效于传统fs-T2WI,其T2图可补充定量评估软骨退变。

研究设计与样本

  • 回顾性研究纳入23例患者(3男、20女,中位年龄62岁),均行3.0 T肩关节MRI并包含传统与合成fs-T2WI,以传统fs-T2WI为参考标准。

关键影像表现/征象

  • rSNR在盂软骨(p=0.037)和肌腱(p=0.007)差异有统计学意义,而rCNR无显著差异。
  • 在冈上肌腱和上盂唇异常评估中,传统与合成fs-T2WI可互换(一致率差异95%CI上限:冈上肌腱≤3.7%,上盂唇≤2.7%)。
  • 退变软骨T2值在盂软骨(p=0.01)和肱骨头(p=0.02)均显著高于非退变软骨。

诊断标准与关键数值

  • 诊断等效性采用互换性分析:冈上肌腱一致率差异95%CI上限≤3.7%,上盂唇≤2.7%。
  • 软骨退变以传统T2WI判定,退变软骨T2值在盂软骨(p=0.01)和肱骨头(p=0.02)均显著高于非退变软骨。

临床应用与阅片要点

  • 合成fs-T2WI可用于替代传统fs-T2WI评估冈上肌腱和上盂唇病变。
  • 可利用合成T2图定量评估盂肱关节软骨退变,作为形态学评估的补充。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the diagnostic equivalence of GRAPPATINI-derived synthetic fat-saturated (fs-) T2-weighted image (T2WI) compared with conventional fs-T2WI for assessing supraspinatus tendon (SST) and superior labrum, and to investigate the correlation between GRAPPATINI-derived T2 values and glenohumeral joint cartilage degeneration.

MATERIALS AND METHODS: This retrospective study included 23 patients (3 men, 20 women; median age, 62 years) who underwent 3.0 T shoulder MRI including both conventional and synthetic fs-T2WIs. Image quality was quantitatively assessed using relative signal-to-noise ratio (rSNR) and contrast-to-noise ratio (rCNR) at fluid, muscle, glenoid cartilage, humeral cartilage, and tendon, and compared using Wilcoxon signed rank test. Four radiologists independently evaluated the detectability of SST and superior labral lesions, and diagnostic equivalence was assessed using an interchangeability analysis. T2 values were measured in two regions of interest in each of the glenoid and humeral head cartilage, and compared between degenerated and non-degenerated cartilage on conventional T2WI using Mann-Whitney U test.

RESULTS: rSNR differed significantly in glenoid cartilage (p = 0.037) and tendon (p = 0.007), whereas rCNR showed no significant differences. For lesion detectability, conventional and synthetic fs-T2WI were interchangeable in evaluating SST and superior labral abnormalities (upper limits of 95% confidence interval for differences in agreement rates ≤ 3.7% for SST and ≤ 2.7% for labrum). T2 values were significantly higher in degenerated cartilage than in non-degenerated cartilage in both the glenoid (p = 0.01) and the humeral head (p = 0.02).

CONCLUSION: GRAPPATINI-derived synthetic fs-T2WIs were diagnostically equivalent to conventional fs-T2WI for evaluating SST and superior labral lesions. In addition, GRAPPATINI-derived T2 maps enabled supplementary quantitative assessment of cartilage degeneration.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Park H, Lee S, Kim DK, et al. Synthetic T2-weighted images and T2 quantification using GRAPPATINI for shoulder joint evaluation: comparison with conventional T2-weighted images. Skeletal Radiol. 2025. PMID: 41400903. doi:10.1007/s00256-025-05102-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。