MRI上实用形态学比值对盘状外侧半月板的诊断准确性
这项回顾性诊断准确性研究纳入212名成人的1.5-T膝关节MRI,评估a/b比值(外侧半月板体部最短宽度除以其距外侧胫骨棘的内侧偏移)诊断盘状外侧半月板(DLM)的准确性。a/b比值在DLM组显著高于对照组(3.80 ± 5.4 vs. 0.47 ± 0.16,p < 0.001),截断值≥0.764时AUC 0.996(95% CI 0.991-1.000),敏感度100%、特异度96.2%。作者认为该比值实用且可重复,纳入常规MRI解读可能提高诊断信心并辅助术前规划。
要点
- a/b比值截断值≥0.764诊断DLM的敏感度100%、特异度96.2%,AUC 0.996(95% CI 0.991-1.000)。
- 完全型DLM的a/b比值显著高于不完全型(12.2 ± 7.4 vs. 1.9 ± 1.8,p < 0.001)。
- a/b比值的观察者间和观察者内一致性均为优秀(ICC分别为0.935和0.972)。
核心结论
- a/b比值是一种实用且可重复的MRI指标,对DLM具有优秀的诊断准确性;纳入常规MRI解读可能提高诊断信心并辅助术前规划。
研究设计与样本
- 回顾性诊断准确性研究,纳入212名成人(平均年龄44.8 ± 9.7岁,56.1%女性),于2020年至2022年间接受1.5-T膝关节MRI;DLM组106例按既定MRI标准定义,并设等量年龄和性别匹配的无盘状形态对照组;参考标准为两名肌骨放射科医师共识MRI诊断。
关键影像表现/征象
- DLM组的a/b比值显著高于对照组(3.80 ± 5.4 vs. 0.47 ± 0.16,p < 0.001)。
- 完全型DLM的a/b比值显著高于不完全型(12.2 ± 7.4 vs. 1.9 ± 1.8,p < 0.001)。
- DLM组的胫骨隆突宽度和外侧胫骨棘角也更大(p < 0.001)。
诊断标准与关键数值
- a/b比值定义为外侧半月板体部最短宽度(a)除以其距外侧胫骨棘的内侧偏移(b)。
- a/b比值截断值≥0.764诊断DLM的AUC为0.996(95% CI 0.991-1.000),敏感度100%、特异度96.2%。
- 完全型与不完全型DLM鉴别的AUC为0.990(95% CI 0.972-1.000)。
- a/b比值的观察者间ICC为0.935,观察者内ICC为0.972。
临床应用与阅片要点
- 作者认为将a/b比值纳入常规MRI解读可能提高DLM的诊断信心并辅助术前规划。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To determine the diagnostic accuracy of a practical morphometric MRI ratio (a/b ratio) for identifying discoid lateral meniscus (DLM).
MATERIALS AND METHODS: This retrospective diagnostic accuracy study included 212 adults (mean age 44.8 ± 9.7 years; 56.1% female) who underwent 1.5-T knee MRI between 2020 and 2022. The DLM group (n = 106) was defined according to established MRI criteria, with an equal number of age- and sex-matched controls without discoid morphology. The index test was the a/b ratio, defined as the shortest lateral meniscal body width (a) divided by its medial offset from the lateral tibial spine (b). Additional evaluated morphometric parameters were tibial eminence width, tibial spine heights, and angles. The reference standard was consensus MRI diagnosis by two musculoskeletal radiologists. Diagnostic accuracy was assessed using ROC analysis, and measurement reproducibility was evaluated with intraclass correlation coefficients (ICC).
RESULTS: The a/b ratio was significantly higher in DLM than in controls (3.80 ± 5.4 vs. 0.47 ± 0.16; p < 0.001). A cut-off ≥ 0.764 yielded excellent diagnostic accuracy (AUC 0.996, 95% CI 0.991-1.000), with 100% sensitivity and 96.2% specificity. Complete DLM demonstrated markedly higher ratios than incomplete types (12.2 ± 7.4 vs. 1.9 ± 1.8; p < 0.001; AUC 0.990, 95% CI 0.972-1.000). Inter- and intra-observer agreement for the ratio was excellent (ICC 0.935 and 0.972, respectively). Tibial eminence width and lateral tibial spine angle were also greater in DLM (p < 0.001).
CONCLUSION: The a/b ratio is a practical and reproducible MRI-based metric with excellent diagnostic accuracy for DLM. Incorporation into routine MRI interpretation may enhance diagnostic confidence and aid preoperative planning.
引用
- Cilengir AH, Kucukciloglu Y, Sinci KA, et al. The diagnostic accuracy of a practical morphometric ratio on MRI for the discoid lateral meniscus. Skeletal Radiol. 2025. PMID: 41384962. doi:10.1007/s00256-025-05107-w
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。