本回顾性研究纳入126例脊椎间盘炎和162例退行性脊柱疾病患者,由两名评估者分析12项MRI特征,筛选出5项最具显著性特征构建SPONDY-Score,最佳阈值为5分;在测试集中联合椎旁积液,模型准确率89%、敏感度95%、特异度85%。

要点

  • SPONDY-Score包含5项MRI特征,最佳阈值为5分
  • 联合椎旁积液作为脊椎间盘炎指标时,测试集准确率89%、敏感度95%、特异度85%
  • MRI特征观察者间κ值0.61-0.90,一致率85%-98%

核心结论

  • SPONDY-Score展现出优异的诊断性能,为临床决策提供了一种准确且标准化的方法。

研究设计与样本

  • 回顾性研究,纳入126例脊椎间盘炎和162例退行性脊柱疾病患者,两名评估者审查MRI报告12项特征,数据集按75:25随机分为训练集和测试集,采用逻辑回归系数构建评分。

关键影像表现/征象

  • 骨水肿累及后部结构计1分
  • 椎体破坏计15分
  • 椎旁水肿计5分
  • 椎间盘T2低信号计-4分
  • 椎间盘非解剖性T2高信号计1分

诊断标准与关键数值

  • SPONDY-Score最佳阈值设为5分
  • 测试集中联合椎旁积液作为脊椎间盘炎指标,模型准确率89%、敏感度95%、特异度85%
  • MRI特征观察者间κ值范围0.61-0.90,一致率范围85%-98%

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the diagnostic performance of a MRI-based scoring system to differentiate endplate edema related to spondylodiscitis and degenerative spine disease (DSD).

METHODS: This retrospective study included 126 patients with spondylodiscitis and 162 with DSD. MRI scans were reviewed by two raters to report 12 features. Excluding collections, which were deemed pathognomonic of spondylodiscitis, the top five most significant features were selected and used for logistic regression. The dataset was randomly split into training and testing sets (75:25). We used the coefficients deriving from logistic regression to construct a clinical score (SPONDY-Score), which would assign said points to each included variable and chose the best threshold for such score. Reproducibility of MRI features was evaluated by calculating Cohen κ and raw concordance.

RESULTS: The SPONDY-Score involved the assignment of 1 point for the involvement of posterior elements by bone edema, 15 points for vertebral bodies destruction, 5 points for the presence of paravertebral edema, -4 points for the presence of T2 hypointensity of the disc, 1 point for the presence of non-anatomical T2 hyperintensity of the disc. The best threshold was set at 5 points. When the SPONDY-Score was applied to the testing set, combined with the presence of paravertebral collections as indicator of spondylodiscitis, the model obtained 89 % accuracy, 95 % sensitivity and 85 % specificity. Regarding inter-observer reproducibility, κ values and concordance ranged from 0.61 to 0.90 and from 85 % to 98 %, respectively.

CONCLUSION: The SPONDY-Score demonstrated excellent diagnostic performance, providing an accurate and standardized method for clinical decision-making.