文献速递骨肌DR

复位前与复位后X线片对肩关节前脱位骨质损伤的诊断价值

The diagnostic value of pre- and post-reduction radiographs in anterior shoulder dislocation.
PubMed 文献 · Skeletal Radiol · 2025-12-09

该回顾性连续样本研究纳入2022年1月至2023年7月于OLVG(阿姆斯特丹)急诊就诊的≥12岁肩关节前脱位患者268例,比较复位前与复位后X线片对骨质损伤的敏感度和阴性预测值,并以至少一次观察到病灶为参考标准。结果显示复位后X线片对盂缘骨缺损和骨性Bankart损伤的敏感度与阴性预测值均高于复位前X线片,Hill-Sachs损伤、大结节骨折和游离体的敏感度95%CI有重叠;患者年龄、性别及某些骨质损伤的存在与其他损伤的存在相关。

要点

  • 复位后X线片对盂缘骨缺损和骨性Bankart损伤的敏感度高于复位前X线片。
  • 复位前X线片对骨性Bankart损伤的敏感度可低至7%。
  • 患者年龄、性别及某些骨质损伤的存在与其他损伤的存在相关。

核心结论

  • 复位后X线片对骨质损伤的诊断特性优于复位前X线片;患者年龄、性别及某些骨质损伤的存在与其他损伤的存在相关。

研究设计与样本

  • 回顾性连续样本研究,纳入2022年1月至2023年7月于OLVG(阿姆斯特丹)急诊就诊的≥12岁肩关节前脱位患者268例,比较复位前与复位后X线片的敏感度和阴性预测值,以病灶至少一次被观察到为参考标准。

诊断标准与关键数值

  • 盂缘骨缺损(n=30):复位前X线片敏感度20-56%、阴性预测值91-94%,复位后X线片敏感度61-92%、阴性预测值95-99%。
  • 骨性Bankart损伤(n=24):复位前X线片敏感度7-42%、阴性预测值68-94%,复位后X线片敏感度91-94%、阴性预测值97-99%。
  • Hill-Sachs损伤(n=187):复位前X线片敏感度72-84%、阴性预测值60-72%,复位后X线片敏感度80-90%、阴性预测值68-81%,复位前95%CI较低但与复位后部分重叠。
  • 大结节骨折(n=45):复位前X线片敏感度76-96%、阴性预测值95-99%,复位后X线片敏感度79-97%、阴性预测值96-99%,复位前95%CI较低但与复位后部分重叠。
  • 游离体(n=14):复位前X线片敏感度13-65%、阴性预测值95-98%,复位后X线片敏感度42-92%、阴性预测值97-99%,复位前95%CI较低但与复位后部分重叠。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Determine the diagnostic characteristics of pre-reduction and post-reduction radiographs for bony lesions, identify associations between patient groups and bony lesions, and identify associations between the presence of certain bony lesions and others.

MATERIALS AND METHODS: A retrospective consecutive sample of anterior shoulder dislocation patients ≥ 12 years old presenting to the emergency department of the OLVG (Amsterdam) between January 2022 and July 2023 was included. The sensitivity and negative predictive value (NPV) for bony lesions on pre-reduction and post-reduction radiographs were compared. A reference standard was established by considering a lesion present when observed at least once. Associations with lesions were expressed as phi-values and R-values.

RESULTS: Among 268 patients, the sensitivity and NPV of pre-reduction radiographs were lower compared to post-reduction radiographs for glenoid bone loss (sensitivity = 20-56% vs 61-92%; NPV = 91-94% vs 95-99%; n = 30) and bony Bankart lesions (sensitivity = 7-42% vs 91-94%; NPV = 68-94% vs 97-99%; n = 24). The 95% CI of pre-reduction radiographs were lower but had some overlap with post-reduction radiographs for Hill-Sachs lesions (sensitivity = 72-84% vs 80-90%; NPV = 60-72% vs 68-81%; n = 187), greater tubercle fractures (sensitivity = 76-96% vs 79-97%; NPV = 95-99% vs 96-99%; n = 45), and loose bodies (sensitivity = 13-65% vs 42-92%; NPV = 95-98% vs 97-99%; n = 14). Poor to very strong associations were identified between sex, age, and lesions with the presence of (other) lesions.

CONCLUSION: Post-reduction radiographs showed better diagnostic characteristics compared to pre-reduction radiographs for the identification of bony lesions. The age and sex of the patient and the presence of certain bony lesions were observed to be associated with the presence of (other) lesions.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Rutgers C, Hameed A, Verweij LPE, et al. The diagnostic value of pre- and post-reduction radiographs in anterior shoulder dislocation. Skeletal Radiol. 2025. PMID: 41364362. doi:10.1007/s00256-025-05095-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。