对比增强超声甲状腺影像报告与数据系统评估甲状腺结节的诊断效能与观察者间一致性:一项回顾性多中心研究
该回顾性多中心研究纳入三个医疗中心2022年1月至8月连续接受常规超声和对比增强超声(CEUS)检查的483例患者共515个经病理证实的甲状腺结节(315个恶性),由四名读者分别按ACR TI-RADS和CEUS TI-RADS分类。CEUS TI-RADS诊断准确率(85.6%-88.5% vs 77.5%-84.5%,p<0.05)和特异度(68.0%-78.0% vs 45.5%-62.5%,p<0.05)优于ACR TI-RADS,敏感度相似(95.2%-97.1% vs 97.8%-98.4%,p>0.05),对于≥1 cm结节不必要细针穿刺活检率更低(27.8% vs 35.5%,p<0.05),CEUS TI-RADS分类的观察者间一致性极好(组内相关系数0.896)。
要点
- CEUS TI-RADS诊断准确率85.6%-88.5%、特异度68.0%-78.0%,均优于ACR TI-RADS。
- CEUS TI-RADS敏感度95.2%-97.1%,与ACR TI-RADS的97.8%-98.4%相似,无显著差异。
- ≥1 cm结节中CEUS TI-RADS不必要活检率27.8%,低于ACR TI-RADS的35.5%。
核心结论
- CEUS TI-RADS标准具有满意的观察者间一致性,显著提高了甲状腺结节的诊断效能和细针穿刺活检推荐质量。
研究设计与样本
- 回顾性多中心研究,纳入三个医疗中心2022年1月至8月连续接受常规超声和CEUS检查的患者483例(平均年龄46.8±12.8岁,女性354例),共515个经病理证实的甲状腺结节(315个恶性),由四名读者按ACR TI-RADS和CEUS TI-RADS分类,以病理为参考标准。
诊断标准与关键数值
- CEUS TI-RADS诊断准确率85.6%-88.5%,高于ACR TI-RADS的77.5%-84.5%(p<0.05);特异度68.0%-78.0%,高于ACR TI-RADS的45.5%-62.5%(p<0.05);敏感度95.2%-97.1%,与ACR TI-RADS的97.8%-98.4%无显著差异(p>0.05)。
临床应用与阅片要点
- 对于≥1 cm的甲状腺结节,CEUS TI-RADS的不必要细针穿刺活检率为27.8%,低于ACR TI-RADS的35.5%(p<0.05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: This study aimed to evaluate the diagnostic performance and inter-observer consistency of contrast-enhanced ultrasound (CEUS) Thyroid Imaging Reporting and Data System (TI-RADS) for the risk stratification of thyroid nodules.
METHODS: This study retrospectively included consecutive patients with thyroid nodules who underwent non-enhanced US and CEUS examinations from three medical centers between January 2022 and August 2022. Four readers evaluated the US features of these thyroid nodules and classified them according to the American College of Radiology (ACR) TI-RADS and CEUS TI-RADS. The diagnostic performance of CEUS TI-RADS and the unnecessary fine needle aspiration biopsy rate were assessed and compared with ACR TI-RADS. Intra-class correlation coefficients were used for assessing the multi-reader consistency.
RESULTS: A total of 483 patients (mean age, 46.8 ± 12.8 years; 354 females) with 515 pathology-proven thyroid nodules (315 malignant) were included. CEUS TI-RADS had better diagnostic accuracy (85.6%-88.5% vs. 77.5%-84.5%, p<0.05) and specificity (68.0%-78.0% vs. 45.5%-62.5%, p<0.05), while obtaining a similar sensitivity as ACR TI-RADS (95.2%-97.1% vs. 97.8%-98.4%, p>0.05). The unnecessary biopsy rate of CEUS TI-RADS was lower than that of ACR TI-RADS (27.8% vs. 35.5%, p<0.05) for 1 cm or larger nodules. Excellent inter-reader consistency was gained in the assessment of the CEUS TI-RADS categories (with an intra-class correlation coefficient of 0.896). Meanwhile, moderate to good inter-reader consistency was obtained in the assessment of the CEUS features (with intra-class correlation coefficients ranging from 0.500 to 0.846).
CONCLUSION: With satisfactory inter-reader consistency, the CEUS TI-RADS criteria significantly improved diagnostic performance and fine needle aspiration biopsy recommendations for thyroid nodules.
引用
- Ye X, Zhang YQ, Zhang LH, et al. The Diagnostic Performance and Interobserver Consistency of Contrast-enhanced Ultrasound Thyroid Imaging Reporting and Data System for Assessing Thyroid Nodules: A Retrospective and Multicenter Study. Ultrasound Med Biol. 2025. PMID: 41469264. doi:10.1016/j.ultrasmedbio.2025.11.666
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。