文献速递乳腺MR

基于多参数磁共振成像放射组学与机器学习鉴别乳腺良恶性肿块

Differentiating malignant from benign breast masses: a multiparametric magnetic resonance imaging (MRI)-based radiomics approach with machine learning.
PubMed 文献 · Clin Radiol · 2025-11-05

回顾性分析144例乳腺病变患者(69例恶性、75例良性)的多参数MRI放射组学特征,比较不同MRI序列组合的机器学习模型鉴别良恶性的性能。全序列模型平均准确率0.88,优于单序列模型;无对比剂序列组合(T2、ADC、平扫T1)平均准确率0.90,与全序列模型相当。

要点

  • 无对比剂序列(T2、ADC、平扫T1)放射组学模型平均准确率0.90,与全序列模型相当。
  • 全序列模型平均准确率0.88,优于任何单序列模型。
  • 单序列模型中ADC、平扫T1、增强T1准确率相似,T2模型略低。

核心结论

  • 无对比剂MRI放射组学算法有潜力作为临床补充工具,可能免除MRI检查中的对比剂使用。

研究设计与样本

  • 回顾性分析144例乳腺病变患者(69例恶性、75例良性),手动分割后从每个病灶提取107个形状和纹理特征,训练支持向量分类器、随机森林和k近邻分类器,采用七种输入图像集(五种单序列及两种组合序列)评估模型。

诊断标准与关键数值

  • 单序列模型在ADC、平扫T1和增强T1上准确率相似,T2模型准确率略低。
  • 全序列模型平均准确率0.88,优于单序列模型。
  • 无对比剂序列模型(T2、ADC、平扫T1)平均准确率0.90,与全序列模型相当。

临床应用与阅片要点

  • 无对比剂MRI放射组学算法有潜力作为临床补充工具,可能免除MRI检查中的对比剂使用。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: We evaluated the performance of radiomics models based on multiparametric magnetic resonance imaging (MRI; dynamic contrast-enhanced, T2, and apparent diffusion coefficient (ADC) sequences) in differentiating malignant from benign masses. Various combinations of MRI sequences were compared.

MATERIALS AND METHODS: One hundred forty-four patients with breast lesions (69 malignant and 75 benign) were retrospectively analysed. After manual segmentation, 107 shape- and texture-based features were extracted from each lesion. Support vector classifier, random forest, and k-nearest neighbours were trained to distinguish malignant and benign lesions. The models were evaluated with seven different input image sets: five single-sequence images and two combined sets (all sequences vs all contrast-free sequences).

RESULTS: Single-sequence models achieved similar accuracies for ADC, pre-contrast T1, and post-contrast T1, while T2 models showed slightly lower accuracy. The all-sequence model achieved an average accuracy of 0.88, outperforming the single-sequence models. The contrast-free sequence models (T2, ADC, and pre-contrast T1) yielded an average accuracy of 0.90, comparable to the all-sequence model.

CONCLUSION: Non-contrast MRI radiomics algorithms have the potential for clinical implementation as complementary tools, potentially eliminating the need for contrast in MRI studies.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Arian A, Azhdeh S, Ahmadinejad N, et al. Differentiating malignant from benign breast masses: a multiparametric magnetic resonance imaging (MRI)-based radiomics approach with machine learning. Clin Radiol. 2025. PMID: 41338155. doi:10.1016/j.crad.2025.107157

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。