AI-CAD在诊断性乳腺X线摄影中的表现:不同检查指征下与放射科医生的比较

AI-CAD for diagnostic mammography: comparison to radiologists according to different indications.
PubMed 文献 · Eur Radiol · 2025-12-24

本研究回顾性纳入1534例于2015年3月至2016年2月接受诊断性乳腺X线摄影的女性,按症状性、BI-RADS 3随访、异常影像转诊三种指征分组,比较AI-CAD异常评分在厂商推荐10%与ROC优化50%阈值下与放射科医生的诊断效能。50%阈值下AI-CAD特异度、准确率、PPV显著高于放射科医生,AUC相当;症状性组AUC显著更高。

要点

  • 50%阈值下AI-CAD特异度95.0%、准确率91.7%、PPV 85.1%,均显著高于放射科医生。
  • AI-CAD与放射科医生AUC相当(0.886 vs 0.882,p=0.75)。
  • 症状性组AI-CAD的AUC显著高于放射科医生(0.873 vs 0.815,p=0.002)。

核心结论

  • AI-CAD在乳腺X线摄影中诊断效能与放射科医生相当,优化阈值下特异度、PPV和准确率更优,症状性患者中提高阈值可在不牺牲敏感度的情况下提升诊断效能。

研究设计与样本

  • 回顾性研究纳入1534例女性(平均年龄51.4±8.8岁),2015年3月至2016年2月接受诊断性乳腺X线摄影,按症状性、BI-RADS 3随访、异常影像转诊三种指征分组,以病理或≥2年影像稳定为最终诊断,比较商用AI-CAD异常评分(0-100%)在厂商推荐10%与ROC优化50%阈值下与放射科医生原始判读的效能。

诊断标准与关键数值

  • 397例(25.9%)诊断为乳腺癌;50%阈值下AI-CAD特异度95.0% vs 放射科医生86.2%、准确率91.7% vs 87.2%、PPV 85.1% vs 69.5%(均p<0.001);AUC AI-CAD 0.886 vs 放射科医生0.882(p=0.75);症状性组AUC AI-CAD 0.873 vs 放射科医生0.815(p=0.002)。

临床应用与阅片要点

  • 在诊断性乳腺X线摄影中可参考AI-CAD异常评分,采用ROC优化50%阈值时特异度、准确率和PPV高于放射科医生判读,症状性患者中提高阈值可在不牺牲敏感度的情况下提升诊断效能;BI-RADS 3随访和异常影像转诊组特异度提高但敏感度降低。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Although artificial intelligence-based computer-aided diagnosis (AI-CAD) is increasingly applied in screening mammography, its use in diagnostic settings is less established. This study evaluated the diagnostic performance of AI-CAD abnormality scores at optimized thresholds across various diagnostic indications vs radiologists.

MATERIALS AND METHODS: This retrospective study included 1534 women (mean age, 51.4 ± 8.8 years) who underwent diagnostic mammography between March 2015 and February 2016. Cases were categorized into three diagnostic indications: (1) symptomatic, (2) BI-RADS 3 follow-up, and (3) referral for abnormal imaging. A commercially available AI-CAD system provided abnormality scores (0-100%). Final diagnosis was confirmed by pathology or ≥ 2-year imaging stability. AI-CAD performance (sensitivity, specificity, accuracy, PPV, and AUC was evaluated at two thresholds: vendor-recommended 10% for screening and an optimized 50% from ROC analysis (Youden's index), and compared with original radiologist interpretations.

RESULTS: Among the 1534 patients, 397 (25.9%) were diagnosed with breast cancer. At the 50% threshold, AI-CAD showed significantly higher specificity (95.0% vs 86.2%), accuracy (91.7% vs 87.2%), and PPV (85.1% vs 69.5%) than radiologists (all p < 0.001). AUCs were comparable (AI-CAD: 0.886; radiologists: 0.882; p = 0.75). In symptomatic patients, AUC was significantly higher than radiologists (0.873 vs 0.815, p = 0.002); in BI-RADS 3 follow-ups and asymptomatic imaging-detected abnormalities, specificity was improved with a tradeoff in lower sensitivity.

CONCLUSION: AI-CAD demonstrated diagnostic performance comparable to radiologists in mammography and, at an optimized threshold, offered superior specificity, PPV, and accuracy. Especially in symptomatic patients, a higher threshold increased diagnostic performance without compromising sensitivity.

KEY POINTS: Question AI-CAD has the potential to be applied for diagnostic mammography by applying different thresholds. Findings Using an optimized threshold, AI-CAD demonstrated higher specificity, accuracy, and positive predictive value compared to radiologists. Clinical relevance When an optimized threshold is applied, AI-CAD shows comparable performance to radiologists, with higher specificity, accuracy, and positive predictive value.

来源:Eur Radiol,查看原文。版权归原作者所有。