文献速递妇产影像介入US

新型热平衡技术在超声引导下经皮微波消融治疗子宫肌瘤中的临床疗效:一项回顾性研究

Clinical efficacy of the novel heat-balance technique in ultrasound-guided percutaneous microwave ablation for uterine fibroids: A retrospective study.
PubMed 文献 · Eur J Radiol · 2025-12-01

回顾性分析40例子宫肌瘤行超声引导下经皮微波消融患者,比较新型热平衡技术(HB型)与传统技术的临床疗效。HB型组与常规消融组均实现有效消融,显著疗效比例无统计学差异;HB型组手术时间更短(8 [6-12] min vs. 25 [20-30] min,p < 0.001)且天线置入次数更少(1 [1,2] vs. 5 [3,5],p < 0.001)。结论认为HB型技术消融效果与临床疗效相当,并具有缩短手术时间、减少天线置入次数和降低并发症率的优势。

要点

  • HB型组与常规组均实现有效消融,显著疗效比例分别为93.75%与87.5%,两组间无显著统计学差异。
  • HB型组手术时间8 [6-12] min,显著短于常规组的25 [20-30] min(p < 0.001)。
  • HB型组天线置入次数1 [1,2]次,显著少于常规组的5 [3,5]次(p < 0.001)。

核心结论

  • HB型技术在PMWA中治疗子宫肌瘤的消融效果和临床疗效与常规消融方法相当,并具有缩短手术时间、减少天线置入次数和降低并发症率的优势。

研究设计与样本

  • 回顾性研究,纳入2022年6月至2024年6月期间接受PMWA的40例患者,按手术技术分为常规技术组和新型PMWA(HB型)组,分析相关临床资料并进行术后随访以评估两组临床疗效。

诊断标准与关键数值

  • 所有病例均实现有效消融;HB型组15例(93.75%)和常规消融组14例(87.5%)达到显著疗效,两组间无显著统计学差异。
  • 两种方式均显著改善患者临床症状(p < 0.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the clinical efficacy of the novel Heat-Balance Technique (HB type) in Ultrasound-Guided Percutaneous Microwave Ablation for Uterine Fibroids (PMWA).

METHODS: According to the inclusion and exclusion criteria, 40 patients who underwent PMWA between June 2022 and June 2024 were selected. These patients were divided into two groups based on the specific surgical technique: one using the conventional technique and the other using a novel PMWA (HB-type). Relevant clinical data of the patients were retrospectively analyzed, and all patients were followed up postoperatively to assess the clinical efficacy of the two groups.

RESULTS: All cases achieved effective ablation. Among them, 15 cases (93.75 %) in the HB-type group and 14 cases (87.5 %) in the conventional ablation group achieved marked efficacy, with no significant statistical difference between the two groups. Both modalities significantly improved patients' clinical symptoms (p < 0.001). The HB-type group showed significantly shorter surgical duration (8 [6-12] min vs. 25 [20-30] min; p < 0.001) and fewer antenna placements (1 [1,2] vs. 5 [3,5]; p < 0.001) than the conventional group.

CONCLUSIONS: The HB-type technique in PMWA achieves comparable ablation effects and clinical efficacy to conventional ablation methods for uterine fibroids, while offering distinct advantages: shortened surgical duration, reduced number of antenna placements, and lowered the complication rates.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Sun X, Zhao Y, Chen J, et al. Clinical efficacy of the novel heat-balance technique in ultrasound-guided percutaneous microwave ablation for uterine fibroids: A retrospective study. Eur J Radiol. 2025. PMID: 41338098. doi:10.1016/j.ejrad.2025.112594

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。