文献速递泌尿生殖腹部MR

计算弥散加权成像在膀胱癌膀胱影像报告和数据系统评估中的应用

Application of computed diffusion-weighted imaging in vesical imaging reporting and data system assessment for bladder cancer.
PubMed 文献 · Abdom Radiol (NY) · 2025-12-27

本回顾性诊断准确性研究纳入110例经病理证实的尿路上皮癌患者,评估计算弥散加权成像(cDWI)在VI-RADS评分中替代采集弥散加权成像(aDWI)的可行性。cDWI在b=2000 s/mm²时显著提高对比率和主观病灶清晰度,但信噪比和对比噪声比低于aDWI;两者检测肌层浸润的AUC无显著差异,支持cDWI作为省时的替代方案。

要点

  • cDWI在b=2000 s/mm²时主观病灶清晰度优于aDWI,但客观SNR和CNR低于aDWI。
  • cDWI与aDWI的VI-RADS评分观察者间一致性均为显著(κ=0.784 vs 0.771)。
  • 检测肌层浸润的AUC在两种序列间无显著差异(读者1:0.87 vs 0.86;读者2:0.92 vs 0.88)。

核心结论

  • cDWI在VI-RADS评估中达到与aDWI相当的诊断准确性,同时提高高b值下的病灶清晰度,支持其作为膀胱癌MRI分期的省时替代方案,尽管客观SNR/CNR指标较低。

研究设计与样本

  • 回顾性诊断准确性研究,纳入110例经病理证实的尿路上皮癌患者(平均年龄67.8±9.59岁,100例男性),均行3.0T MRI包括DWI序列(b=0/700/1400/2000 s/mm²);cDWI图像由b=0/700 s/mm²采集计算生成;两名放射科医生(经验2年和4年)独立评估aDWI和cDWI结合T2WI和DCE进行VI-RADS评分;以术后组织病理学为参考标准。

诊断标准与关键数值

  • 在b=2000 s/mm²时,cDWI较aDWI显著提高对比率(所有p<0.001)和主观病灶清晰度(所有p<0.05)。
  • cDWI在所有b值和所有读者中信噪比和对比噪声比均低于aDWI(所有p<0.001)。
  • 两种序列的观察者间一致性均为显著(cDWI κ=0.784;aDWI κ=0.771)。
  • 检测肌层浸润的AUC无显著差异(读者1:0.87 vs 0.86,p=0.70;读者2:0.92 vs 0.88,p=0.052)。

临床应用与阅片要点

  • cDWI可作为省时的替代方案用于膀胱癌MRI的VI-RADS评估,尤其在高b值下可提高病灶清晰度。
  • 尽管cDWI客观SNR/CNR较低,但其诊断准确性与aDWI相当,支持其在临床分期中的应用。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To validate computed diffusion-weighted imaging (cDWI) as a time-efficient alternative to acquired DWI (aDWI) in Vesical Imaging-Reporting and Data System (VI-RADS) assessment for bladder cancer, addressing inherent limitations of low signal-to-noise ratio (SNR) and motion artifacts in conventional high-b-value DWI.

METHODS: This retrospective diagnostic accuracy study evaluated 110 patients (mean age 67.8 ± 9.59 years, 100 men) with pathologically confirmed urothelial carcinoma. All underwent 3.0T MRI including DWI sequences (b = 0/700/1400/2000 s/mm²). cDWI images at b = 1400/2000 s/mm² were computationally generated from b = 0/700 s/mm² acquisitions. Two radiologists (2/4 years' experience) independently assessed both aDWI and cDWI sets paired with T2-weighted imaging (T2WI) and dynamic contrast-enhanced (DCE) for VI-RADS scoring. Objective metrics and subjective image quality were compared. Postoperative histopathology served as the reference standard. Statistical analyses included Wilcoxon signed-rank tests, weighted kappa, McNemar test, and receiver operating characteristic (ROC) analysis with Delong's test for area under the curve (AUC) comparison (α = 0.05).

RESULTS: At b = 2000 s/mm², cDWI significantly improved contrast ratio (CR) (all p < 0.001) and subjective lesion clarity (all p < 0.05). However, cDWI demonstrated lower SNR and contrast-to-noise ratio (CNR) than aDWI across all b-values and readers (all p < 0.001). Substantial inter-reader agreement was confirmed for both sequences (cDWI κ = 0.784; aDWI κ = 0.771). No significant AUC differences were observed for muscle invasion detection (Reader 1: 0.87 vs. 0.86, p = 0.70; Reader 2: 0.92 vs. 0.88, p = 0.052).

CONCLUSION: cDWI achieves diagnostic accuracy comparable to aDWI in VI-RADS assessment while enhancing lesion clarity at high b-values, supporting its utility as a time-efficient alternative for bladder cancer MRI staging despite lower objective SNR/CNR metrics.