SpaceOAR水凝胶置入前后直肠-前列腺距离的定量评估
本研究纳入118例连续接受SpaceOAR水凝胶置入前后MRI检查的患者,在9个位置测量直肠-前列腺距离。置入后所有位置平均距离均显著增加(P < 0.001),全前列腺平均距离从基底部8 ± 3 mm增至尖部12 ± 14 mm,但高达57%的患者置入后未达到7.5 mm的距离。
要点
- SpaceOAR水凝胶置入后各测量点直肠-前列腺平均距离均显著增加(P < 0.001)。
- 全前列腺平均距离增加范围从基底部8 ± 3 mm至尖部12 ± 14 mm。
- 高达57%的患者置入后未达到7.5 mm的直肠-前列腺距离。
核心结论
- SpaceOAR水凝胶虽增加平均直肠-前列腺距离,但其在直肠与前列腺间分布可能不均匀,可能使部分直肠仍处于较高辐射毒性风险中。
研究设计与样本
- 研究纳入118例连续接受SpaceOAR水凝胶置入前后MRI检查的患者,在矢状面(尖部上1 cm、基底下方1 cm、腺体中部水平)和轴面(前列腺左侧1 cm、右侧1 cm、中线)共9个位置测量直肠-前列腺距离,数据记录于Microsoft Excel并比较置入前后。
关键影像表现/征象
- MRI矢状面和轴面共9个位置测量直肠-前列腺距离,置入前后所有位置平均距离差异均显著(P < 0.001)。
- 全前列腺平均直肠-前列腺距离增加,范围从基底部8 ± 3 mm至尖部12 ± 14 mm。
诊断标准与关键数值
- 以7.5 mm直肠-前列腺距离作为辐射毒性考量下的理想距离,置入后高达57%的患者未达到该距离。
临床应用与阅片要点
- SpaceOAR水凝胶置入后应在MRI多位置测量直肠-前列腺距离以评估间隔均匀性。
- 即使平均距离增加,仍需注意高达57%患者未达7.5 mm理想距离,部分直肠可能仍暴露于较高辐射毒性风险。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: Radiation is the standard therapy for prostate cancer. However, it may cause damage to the surrounding organs, including the rectum. SpaceOAR hydrogel is a Food and Drug Administration (FDA)-approved spacer which increases the distance between the rectum and prostate, reducing rectal radiation exposure. A 7.5 mm distance is considered desirable for radiation toxicity purposes. This study aims to quantify the increased recto-prostatic distance after SpaceOAR hydrogel placement.
MATERIALS AND METHODS: A total of 118 consecutive patients who underwent magnetic resonance imaging (MRI) prior to and after SpaceOAR hydrogel placement were included. The distance between the prostate and rectum distance (PRD) was measured in nine different locations, including one centimetre superior to the apex, inferior to the base, and at the level of mid-gland on sagittal views, and one centimetre to the left, right, and midline of the prostate on axial views. The measured data were recorded in Microsoft Excel and compared before and after SpaceOAR hydrogel placement.
RESULTS: The average PRD was significantly different before and after SpaceOAR hydrogel placement at all locations (P < 0.001). The mean PRD increased throughout the entire prostate (ranging from 8 ± 3 mm at base to 12 ± 14 mm at the apex). Although the averages were significantly different, up to 57% of patients did not achieve a PRD of 7.5 mm after SpaceOAR hydrogel placement.
CONCLUSION: Although SpaceOAR hydrogel increases the mean PRD, the distribution of SpaceOAR hydrogel between the rectum and prostate may not be uniform, which may leave some portions of the rectum at increased risk for radiation toxicity.
引用
- Ebrahimian S, Mishyn P, Arora S, et al. Quantitative evaluation of recto-prostatic distance before and after SpaceOAR hydrogel placement. Clin Radiol. 2025. PMID: 41338158. doi:10.1016/j.crad.2025.107150
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。