文献速递腹部US

基于壳层弹性成像的瘤周硬度定量评估提升肝细胞癌与转移性肝癌的鉴别能力

Quantitative Assessment of Peritumoral Stiffness Using Shell Elastography Enhances the Differentiation of Hepatocellular Carcinoma From Metastatic Liver Carcinoma.
PubMed 文献 · J Ultrasound Med · 2025-12-02

本研究纳入31例肝细胞癌与42例转移性肝癌患者,用二维剪切波弹性成像的壳层测量功能测量瘤内及瘤周1、2、3毫米壳层的杨氏模量,并绘制ROC曲线评估鉴别能力。肝细胞癌的Eshell1、Eshell2、Eshell3高于转移性肝癌,而E值低于转移性肝癌(p<.05);Eshell1诊断效能较好,特异度64%、敏感度88%、阳性预测值59%、阴性预测值90%(截断值19.84 kPa,AUC 0.763)。结论认为瘤周硬度定量评估,尤其是1毫米壳层,可显著提升两者的鉴别。

要点

  • 肝细胞癌瘤周1、2、3毫米壳层硬度高于转移性肝癌,而瘤内硬度低于转移性肝癌。
  • Eshell1鉴别效能较好:敏感度88%、特异度64%、阳性预测值59%、阴性预测值90%,截断值19.84 kPa,AUC 0.763。
  • 瘤周硬度定量评估(尤其1毫米壳层)可提升肝细胞癌与转移性肝癌的鉴别。

核心结论

  • 瘤周硬度定量评估,尤其是使用先进壳层弹性成像在精确界定的1毫米壳层内测量,可显著提升肝细胞癌与转移性肝癌的鉴别。

研究设计与样本

  • 研究纳入31例肝细胞癌患者与42例转移性肝癌患者,采用二维剪切波弹性成像结合壳层测量功能测量瘤内及瘤周1、2、3毫米壳层的平均杨氏模量,并以受试者工作特征曲线评估鉴别能力。

关键影像表现/征象

  • 肝细胞癌的Eshell1、Eshell2、Eshell3值高于转移性肝癌,而E值低于转移性肝癌(p<.05)。

诊断标准与关键数值

  • Eshell1鉴别肝细胞癌与转移性肝癌的截断值为19.84 kPa,AUC为0.763,敏感度88%、特异度64%、阳性预测值59%、阴性预测值90%。

临床应用与阅片要点

  • 作者认为瘤周硬度定量评估,尤其是精确界定的1毫米壳层,可显著提升肝细胞癌与转移性肝癌的鉴别。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the discriminatory potential of peritumoral tissue stiffness, as quantified by 2-dimensional shear wave elastography, for distinguishing between hepatocellular carcinoma (HCC) and metastatic liver carcinoma (MLC).

METHODS: This study enrolled 31 patients with HCC and 42 with MLC. The mean Young's modulus (E) value was measured to evaluate the intratumoral and peritumoral stiffness of HCC and MLC by using the 2-dimensional shear wave elastography integrated with the shell measurement function. The intratumoral stiffness and the peritumoral stiffness within the 1-, 2-, and 3-mm shells surrounding the target lesion were labeled as E, Eshell1, Eshell2, and Eshell3, respectively. The discriminatory capacity of the E and Eshell parameters to distinguish HCC from MLC was assessed by generating receiver operating characteristic curves.

RESULTS: The Eshell1, Eshell2, and Eshell3 values in patients with HCC were higher than those with MLC, whereas the E values in patients with HCC were lower than those with MLC (p < .05). In addition, the Eshell1, Eshell2, Eshell3, and E values showed good diagnostic performance in differentiating HCC from MLC. Among them, Eshell1 had better diagnostic performance, with a specificity, sensitivity, positive predictive value, and negative predictive value of 64, 88, 59, and 90%, respectively (cut-off value, 19.84 kPa; area under the receiver operating characteristic curve, 0.763).

CONCLUSIONS: Quantitative assessment of peritumoral stiffness, particularly within a precisely defined 1-mm shell using advanced shell elastography, significantly enhances the differentiation of HCC from MLC.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Li Y, Wu Z, Zhu M, et al. Quantitative Assessment of Peritumoral Stiffness Using Shell Elastography Enhances the Differentiation of Hepatocellular Carcinoma From Metastatic Liver Carcinoma. J Ultrasound Med. 2025. PMID: 41328677. doi:10.1002/jum.70143

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。