文献速递腹部技术与安全MR

0.55 T 腹部深度学习增强扩散加权成像:健康志愿者的图像质量与表观扩散系数计算互换性

Deep Learning-Enhanced Diffusion-Weighted Imaging of the Abdomen at 0.55 T: Image Quality and Apparent Diffusion Coefficient Calculation Interchangeability in Healthy Volunteers.
PubMed 文献 · Acad Radiol · 2025-12-13

研究纳入33名健康志愿者在0.55 T行腹部MRI,比较常规与深度学习增强DWI的图像质量和ADC值。DL重建在b50、b800及ADC图上的质量评分均更高,ADC值组间平均差异0.3%-4.5%,Bland-Altman分析显示偏差在±20%预期范围内。

要点

  • DL增强DWI在b50、b800及ADC图上质量评分均高于常规DWI(P<.001)。
  • DL重建后b50和b800信号强度降低(P<.001),ADC值组间平均差异0.3%-4.5%。
  • ADC值方法间相关性r≥0.61,偏差在±20%互换性范围内(P<.001)。

核心结论

  • DL超分辨率重建可在0.55 T实现更快、更高质量的腹部DWI,ADC值无相关偏差,支持与传统DWI互换使用。

研究设计与样本

  • 前瞻性技术可行性研究,33名健康志愿者(平均年龄30±4岁,男13名),2024年7月至9月在0.55 T行腹部MRI,采集b50和b800的常规与DL增强DWI。

关键影像表现/征象

  • DL增强DWI的b50图像质量中位评分4(IQR 4-5) vs 常规3(IQR 3-4)。
  • DL增强DWI的b800图像质量中位评分4(IQR 4-4) vs 常规3(IQR 3-3)。
  • DL增强DWI的ADC图中位评分4(IQR 4-4) vs 常规3(IQR 3-3)。
  • DL增强DWI的图像噪声、空间分辨率、器官锐利度和伪影评分均更优(P<.001)。

诊断标准与关键数值

  • 图像质量采用Likert 5分制,DL增强DWI在b50、b800和ADC图上评分均高于常规DWI(P<.001)。
  • ADC值方法间相关性r≥0.61(P<.001),正常组织平均差异0.3%-4.5%。
  • Bland-Altman和互换性分析显示ADC值方法间偏差在±20%预期范围内(P<.001)。

临床应用与阅片要点

  • DL增强DWI在0.55 T上可获得优于常规DWI的图像质量,ADC值与常规DWI在±20%内可互换。
  • DL重建后b50和b800信号强度降低(P<.001),判读时需注意信号强度变化。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: Low-field diffusion-weighted imaging (DWI) is limited by inherently lower signal-to-noise ratios. This study evaluated the technical feasibility, image quality, and apparent diffusion coefficient (ADC) reliability of deep learning (DL)-enhanced DWI at low field strength.

MATERIALS AND METHODS: Thirty-three healthy volunteers (mean age: 30 ± 4 years; 13 men) underwent 0.55 T abdominal magnetic resonance imaging from 07/2024-09/2024. Conventional and DL-enhanced DWI were acquired with two b values (b50 s/mm2, b800 s/mm2). Three fellowship-trained abdominal radiologists rated the scans for quality parameters and artifacts (Likert scales, 1-5). Quantitative b50 and b800 signal intensity and ADC values were measured in the right and left liver lobes, spleen and Th12 vertebral body by one reader. Interreader reliability, intermethod concordance, and Bland-Altman analyses were performed.

RESULTS: DL-enhanced scans demonstrated higher quality across all diffusion weightings (all: P < .001): b50 images (median: 4 [IQR: 4-5] vs 3 [3-4]), b800 images (4 [4-4] vs 3 [3-3]), and ADC maps (4 [4-4] vs 3 [3-3]) with good or better interreader agreement (κ ≥ 0.63). Image noise, spatial resolution, organ sharpness and artifacts were rated better for DL-enhanced DWI (all: P < .001). Mean b50 and b800 signal intensities were lower with DL reconstruction (all: P < .001). ADC values showed at least strong intermethod correlation (r ≥ 0.61; all: P < .001) with mean differences of 0.3%-4.5% in normal tissues. Bland-Altman plots and interchangeability analysis confirmed intermethod ADC value deviations within expected margins of ±20% (all: P < .001).

CONCLUSION: DL superresolution reconstruction enables faster and higher quality abdominal DWI at 0.55 T without relevant ADC deviations, supporting interchangeability with conventional DWI.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Seifert AC, Obmann MM, Breit HC, et al. Deep Learning-Enhanced Diffusion-Weighted Imaging of the Abdomen at 0.55 T: Image Quality and Apparent Diffusion Coefficient Calculation Interchangeability in Healthy Volunteers. Acad Radiol. 2025. PMID: 41391962. doi:10.1016/j.acra.2025.11.039

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。