结直肠癌患者的光谱CT:利用虚拟单能成像对黏液性和非黏液性腹膜转移进行定量对比病灶评估
这项前瞻性单中心研究纳入55例拟行肿瘤细胞减灭术联合腹腔热灌注化疗的结直肠癌患者,分析92个腹膜转移灶(24个黏液性、68个非黏液性),在双层光谱CT虚拟单能图像40–200 keV上计算信噪比和对比噪声比。结果显示40 keV时病灶衰减、信噪比及对比噪声比最高,非黏液性转移灶从50 keV起信噪比和对比噪声比显著下降,低能虚拟单能图像可改善腹膜转移灶的显示。
要点
- 40 keV虚拟单能图像上腹膜转移灶的信噪比和对比噪声比最高,且随能量升高而下降。
- 非黏液性腹膜转移灶从50 keV起信噪比和对比噪声比显著下降(p<0.05)。
- 40 keV时腹膜转移灶的可见度和锐利度显著高于更高能量水平(p<0.05)。
核心结论
- 光谱CT低能虚拟单能图像显著提高腹膜转移灶的信噪比和对比噪声比,尤其对非黏液性腹膜转移灶,支持将其整合入术前阅片方案。
研究设计与样本
- 前瞻性单中心研究,纳入2023年9月1日至2025年5月1日期间连续55例拟行肿瘤细胞减灭术联合腹腔热灌注化疗的结直肠癌患者,术前7天内行增强双层光谱CT,以组织病理学将腹膜转移灶分为黏液性和非黏液性。
关键影像表现/征象
- 黏液性腹膜转移灶在40 keV时衰减为42.47±23.81,信噪比为3.00±2.01,与肠系膜脂肪的对比噪声比为12.36±3.78,与邻近器官的对比噪声比为7.30±3.71,均随能量水平升高而下降。
- 非黏液性腹膜转移灶在40 keV时衰减为131.16±50.17,信噪比为9.88±5.38,与肠系膜脂肪的对比噪声比为21.89±10.57,与邻近器官的对比噪声比为5.62±3.07,均随能量水平升高而下降。
- 图像噪声在40–200 keV范围内保持稳定。
诊断标准与关键数值
- 在40–200 keV虚拟单能图像上计算腹膜转移灶的信噪比、与肠系膜脂肪的对比噪声比、与邻近器官的对比噪声比。
- 腹膜转移灶的可见度和锐利度在40–120 keV范围内评估。
- 非黏液性腹膜转移灶从50 keV起信噪比和与邻近器官的对比噪声比显著下降(p<0.05)。
- 40 keV时腹膜转移灶可见度和锐利度显著更高(p<0.05)。
临床应用与阅片要点
- 作者认为低能虚拟单能图像可整合入术前阅片方案,以改善腹膜转移灶的信噪比和对比噪声比。
- 非黏液性腹膜转移灶从50 keV起信噪比和与邻近器官的对比噪声比显著下降,阅片时需关注能量水平对病灶显示的影响。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To objectively evaluate quantitative image parameters-signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR)-of peritoneal metastases (PMs) from colorectal cancer (CRC) on virtual monoenergetic images (VMIs) reconstructed from dual-layer spectral CT (DLCT) technology.
MATERIALS AND METHODS: This prospective single-center study included consecutive patients scheduled for cytoreductive surgery (CRS) with hyperthermic intraperitoneal chemotherapy (HIPEC) between September 1, 2023, and May 1, 2025. All patients underwent contrast-enhanced DLCT < 7 days before surgery. SNR, CNR between PMs and mesenteric fat (CNR MF), CNR between PMs and adjacent organ (CNR AO) were calculated on VMIs ranging from 40 to 200 keV. PMs were classified as mucinous (mPMs) or non-mucinous (nmPMs) based on histopathology. PM conspicuity and sharpness were also evaluated between 40 and 120 keV.
RESULTS: A total of 92 PMs (24 mPMs, 68 nmPMs) in 55 patients were analyzed. For both mPMs and nmPMs, attenuation, SNR, CNR MF, CNR AO, were highest at 40 keV (42.47 ± 23.81, 3.00 ± 2.01, 12.36 ± 3.78, 7.30 ± 3.71, and 131.16 ± 50.17, 9.88 ± 5.38, 21.89 ± 10.57, 5.62 ± 3.07, respectively) and decreased with increasing energy levels. In nmPMs, CNRAO and SNR declined significantly from at 50 keV onward (p < 0.05). Image noise remained stable across the 40-200 keV range. PM conspicuity and sharpness were significantly higher at 40 keV (p < 0.05).
CONCLUSION: Low-energy VMIs obtained from spectral CT significantly improve SNR and CNR of PMs, particularly for nmPMs, supporting their integration into preoperative reading protocols.
引用
- Grange R, Si-Mohamed S, Benzerdjeb N, et al. Spectral CT in patients with colorectal cancer: quantitative contrast lesional assessment of mucinous and non-mucinous peritoneal metastases using virtual monoenergetic imaging. Abdom Radiol (NY). 2025. PMID: 41454946. doi:10.1007/s00261-025-05355-3