黏度平面波超声联合血清生物标志物检测显著肝脏炎症:一项诊断列线图研究
本研究纳入2024年7月26日至11月30日接受超声引导下肝活检的140例患者,其中98例为显著炎症组(≥G2),42例为轻度炎症组(G0-G1)。基于黏度平面波超声均值(Vi PLUS mean)和天冬氨酸氨基转移酶(AST)构建的列线图预测显著肝脏炎症的AUC为0.941(95%CI 0.898-0.983,敏感度92.9%,特异度85.7%),优于AST/血小板比率指数、Vi PLUS均值、FIB-4、AST和γ-谷氨酰转肽酶/血小板比率指数。列线图校准曲线拟合良好, cutoff值为0.538。
要点
- Vi PLUS均值联合AST构建的列线图预测显著肝脏炎症AUC达0.941,敏感度92.9%,特异度85.7%。
- 列线图预测显著肝脏炎症的cutoff值为0.538。
- 列线图诊断性能优于AST/血小板比率指数、Vi PLUS均值、FIB-4、AST和γ-谷氨酰转肽酶/血小板比率指数(均p<0.05)。
核心结论
- 基于Vi PLUS均值和AST的列线图在预测显著肝脏炎症方面表现出较高准确性,为临床医生更好地评估炎症活动提供新方法。
研究设计与样本
- 诊断列线图研究,纳入2024年7月26日至11月30日接受超声引导下肝活检的患者140例,收集人口学数据、实验室参数、黏度平面波超声(Vi PLUS)均值及组织病理学炎症分级和纤维化分期,以多因素logistic回归构建列线图,采用受试者工作特征曲线、校准曲线和决策曲线评估诊断性能。
诊断标准与关键数值
- 列线图由Vi PLUS均值和AST构建,预测显著肝脏炎症(≥G2)的AUC为0.941(95%CI 0.898-0.983),敏感度92.9%,特异度85.7%,cutoff值0.538;Vi PLUS均值OR为9.060,AST OR为2111.269(p<0.05);对照指标AUC:AST/血小板比率指数0.897、Vi PLUS均值0.897、FIB-4 0.885、AST 0.852、γ-谷氨酰转肽酶/血小板比率指数0.755(均p<0.05)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Accurate prediction of significant liver inflammation is critical for making clinical intervention decisions. This study aims to establish a predictive model for detection of significant liver inflammation and assess its diagnostic performance against established scoring systems.
METHOD: This study enrolled patients who underwent ultrasound-guided liver biopsy between July 26, 2024, and November 30, 2024. Demographic data, laboratory parameters, viscosity plane-wave ultrasound (Vi PLUS), mean values and histopathological inflammation grading, fibrosis stage were collected. A nomogram model was generated based on a multivariate logistic regression analysis to identify potential predictors associated with liver inflammation. The diagnostic performance was evaluated by receiver operating characteristic curve analysis, calibration plot and decision curve.
RESULT: A total of 140 participants were included in this study. 98 patients were classified into the significant inflammation group (≥G2), and 42 patients were categorized as mild inflammation (G0-G1). Based on univariate and multivariate logistic regression analyses, Vi PLUS mean (odds ratios [OR]: 9.060) and aspartate aminotransferase (AST) (OR: 2111.269) were identified as independent risk factors for inflammatory grade (p < 0.05). The area under the curve (AUC) of the nomogram constructed by Vi PLUS mean and AST was 0.941 (95% confidence intervals 0.898-0.983, sensitivity 92.9%, specificity 85.7%), outperforming AST to platelet ratio index (AUC = 0.897), Vi PLUS mean (AUC = 0.897), FIB-4 (AUC = 0.885), AST (AUC = 0.852) and gamma-glutamyl transpeptidase to platelet ratio (AUC = 0.755) (all p < 0.05). Furthermore, a well-fitted calibration curve and a good clinical application value were achieved in the nomogram. The cutoff value of 0.538 was determined to predict significant inflammation.
CONCLUSION: The nomogram exhibits high accuracy in predicting significant liver inflammation and provide a new approach for clinicians to better evaluate inflammatory activity.
引用
- Ding X, Dou J, Feng H, et al. Viscosity Plane-Wave Ultrasound Combined With Serum Biomarkers for Detection of Significant Liver Inflammation: A Diagnostic Nomogram Study. Ultrasound Med Biol. 2025. PMID: 41453821. doi:10.1016/j.ultrasmedbio.2025.11.013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。