基于DCE-MRI与DWI定量多参数MRI术前预测胃癌微卫星不稳定性
前瞻性纳入244例经病理免疫组化确认微卫星状态的胃癌患者,两名放射科医师盲法分析术前MRI。DCE-MRI药代动力学参数与多扩散模型参数在MSI-H与MSI-L/MSS间存在显著差异。整合DCE-MRI与DWI的mpMRI模型术前预测MSI-H的AUC为0.841,显著高于任一单参数模型(P<0.05)。
要点
- mpMRI模型整合DCE-MRI与DWI参数,术前预测胃癌MSI-H的AUC为0.841,显著高于单参数模型(P<0.05)。
- DCE-MRI以Ktrans为独立预测因子,模型AUC为0.715;DWI以ADC为独立预测因子,模型AUC为0.740。
- Ktrans、Ve、ADC、MD、DDC及D*在MSI-H与MSI-L/MSS组间差异有统计学意义(P<0.05)。
核心结论
- DCE-MRI与DWI定量参数为术前无创预测胃癌MSI-H状态提供了有效方法,可能在个体化治疗规划中具有临床应用潜力。
研究设计与样本
- 前瞻性研究,纳入244例经免疫组化确认微卫星状态的胃癌患者(MSI-H 30例,MSI-L/MSS 214例);两名放射科医师独立盲法分析术前MRI;采用DCE-MRI药代动力学建模与多扩散模型获取定量参数;以免疫组化结果为参考标准。
诊断标准与关键数值
- MSI-H组与MSI-L/MSS组间Ktrans、Ve、ADC、MD、DDC及D*差异有统计学意义(P<0.05);DCE-MRI模型以Ktrans为独立预测因子,AUC为0.715;DWI模型以ADC为独立预测因子,AUC为0.740;整合DCE-MRI与DWI参数的mpMRI模型AUC为0.841,显著高于任一单参数模型(P<0.05)。
临床应用与阅片要点
- 原文结论认为DCE-MRI与DWI定量参数可用于术前无创预测胃癌MSI-H状态,可能在个体化治疗规划中具有临床应用潜力。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To develop and validate a non-invasive preoperative predictive model utilizing quantitative parameters from dynamic contrast-enhanced MRI (DCE-MRI) and diffusion-weighted imaging (DWI) for determining microsatellite instability (MSI) status in gastric cancer.
METHODS: This prospective study enrolled 244 patients with pathologically confirmed MSI status (30 MSI-H, 214 MSI-L/MSS), determined via immunohistochemistry. Two radiologists independently analyzed preoperative MRI blinded to clinicopathological results. Quantitative parameters were derived from DCE-MRI pharmacokinetic modeling (Ktrans, Vp,Ve, Kep) and multiple diffusion models (ADC, D, D*, f, MD, MK, DDC, α). Inter-observer agreement was assessed using the intraclass correlation coefficient (ICC). Statistical comparisons were performed using t-tests or Mann-Whitney U tests. Multivariate logistic regression was conducted to identify independent predictors and build predictive models.
RESULTS: Significant differences in several parameters, including Ktrans, Ve, ADC, MD, DDC and D*, were observed between MSI-H and MSI-L/MSS cohorts (P < 0.05). The DCE-MRI model, featuring Ktrans as an independent predictor, yielded an area under the curve (AUC) of 0.715. The DWI model, with ADC as an independent predictor, achieved an AUC of 0.740. The comprehensive mpMRI model, which integrated both DCE-MRI and DWI parameters, demonstrated superior preoperative predictive performance, attaining an AUC of 0.841, which was significantly higher than that of any single-parameter model (P < 0.05).
CONCLUSION: Quantitative parameters derived from DCE-MRI and DWI offer a non-invasive and effective approach for preoperatively predicting MSI-H status in gastric cancer, with potential clinical applications in personalized treatment planning.
引用
- Wei XX, Sang ZT, Hou YJ, et al. Preoperative prediction of microsatellite instability in gastric cancer using quantitative multiparametric MRI with DCE-MRI and DWI. Abdom Radiol (NY). 2025. PMID: 41428048. doi:10.1007/s00261-025-05354-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。