文献速递外周血管介入CT

使用深度学习在全自动测量腹主动脉瘤患者髂动脉迂曲度中的准确性

Accuracy of fully automated iliac artery tortuosity measurements in patients with abdominal aortic aneurysm using deep learning.
PubMed 文献 · Eur J Radiol · 2025-12-16

本研究为回顾性多中心验证研究,纳入ZEPHYR注册库270例腹主动脉瘤患者的CTA,将深度学习软件PRAEVAorta 2的髂动脉迂曲度测量与核心实验室手动测量进行对比。21.1%的扫描因明显分割错误被排除,剩余213例中软件与手动测量的Pearson相关系数为0.95,ICC为0.73,Bland-Altman偏倚为-0.09,结论认为该软件在多数病例中可提供全自动测量,但经验丰富的观察者仍需对自动报告进行关键复核。

要点

  • 深度学习软件PRAEVAorta 2可全自动测量腹主动脉瘤患者髂动脉迂曲度。
  • 21.1%的CTA因明显分割错误被排除,常见风险因素为髂内动脉闭塞及重叠动脉瘤。
  • 软件与核心实验室手动测量的ICC为0.73,Bland-Altman偏倚为-0.09。

核心结论

  • PRAEVAorta 2在多数病例中成功提供了髂动脉迂曲度的全自动测量,提示其作为研究和临床应用工具的潜力,但经验丰富的观察者对自动报告进行关键复核仍然必要。

研究设计与样本

  • 回顾性、多中心验证研究,使用ZEPHYR注册库中270例腹主动脉瘤患者的CTA扫描,以国际公认核心实验室(Syntactx,美国纽约)的手动测量为参考标准,由两名观察者对PRAEVAorta 2的分割结果进行视觉检查以判断合理性。

诊断标准与关键数值

  • 在剩余213例扫描中,核心实验室测得髂动脉迂曲度中位数为1.34(IQR 1.23-1.45),PRAEVAorta 2报告的中位数为1.25(IQR 1.19-1.33)。
  • Pearson相关系数为0.95(95% CI:0.94-0.96)。
  • 组内相关系数(ICC)为0.73(95% CI:0.69-0.77)。
  • Bland-Altman分析偏倚为-0.09。

临床应用与阅片要点

  • PRAEVAorta 2可全自动测量髂动脉迂曲度,但经验丰富的观察者对自动报告进行关键复核仍然必要。
  • 髂内动脉闭塞和肾下腹主动脉远端与髂总动脉近端重叠动脉瘤是分割失败的常见风险因素。

局限性

  • 21.1%的扫描在初始审查时显示明显分割错误,被排除在本分析之外。
  • 原文未报告其他局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To externally validate the accuracy of deep learning-based iliac artery tortuosity assessment (PRAEVAorta 2, Bordeaux, France) in computed tomography angiography of patients with abdominal aortic aneurysms.

DESIGN: Retrospective, multi-center validation study.

METHODS: Data from the ZEnith alPHa for aneurYsm Repair Registry (ZEPHYR) were used. Tortuosity measurements from PRAEVAorta 2 were benchmarked against manual reference measurements from an internationally recognized core laboratory (Syntactx, New York, USA). All PRAEVAorta 2 reports were visually inspected by two observers for plausibility of the segmentation of the iliac arteries. Scans with obvious segmentation errors were excluded. Qualitative and quantitative analysis of potential risk factors for segmentation failures were conducted. The core laboratory performed manual tortuosity measurements using standard multiplanar reconstructions.

RESULTS: In total, 270 CTA scans from the ZEPHYR database fulfilled the inclusion criteria and were available for analysis. 21.1 % of scans demonstrated obvious segmentation errors upon initial review and were excluded from this analysis. Most common risk factors for segmentation failure were internal iliac artery occlusions and overlapping aneurysms in the distal infrarenal aorta and proximal common iliac arteries. In the remaining 213 scans, the median iliac tortuosity measured by the core laboratory was 1.34 (IQR 1.23-1.45) while PRAEVAorta 2 reported a median tortuosity of 1.25 (IQR 1.19-1.33). The analysis showed an excellent Pearson correlation of 0.95 (95 % CI: 0.94-0.96) with a moderate to good Intraclass Correlation (ICC) of 0.73 (95 % CI: 0.69-0.77) and a bias of -0.09 in Bland-Altman analysis.

CONCLUSION: PRAEVAorta 2 successfully provided fully automated measurements of the iliac artery tortuosity in most cases, highlighting its potential as a valuable tool for both research and clinical applications. However, a critical review of automatically provided reports by an experienced observer remains essential.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Barb A, Uhl C, Bornhak L, et al. Accuracy of fully automated iliac artery tortuosity measurements in patients with abdominal aortic aneurysm using deep learning. Eur J Radiol. 2025. PMID: 41422647. doi:10.1016/j.ejrad.2025.112609

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。