文献速递外周血管腹部CT

人工智能辅助测量腹主动脉直径在腹主动脉瘤修复临床决策中的应用

Use of artificial intelligence-assisted measurement of aortic diameter in clinical decision making about abdominal aortic aneurysm repair.
PubMed 文献 · Abdom Radiol (NY) · 2025-12-27

本研究对142例患者的CT血管造影扫描,比较人工智能自动测量与半自动测量腹主动脉瘤大小的可重复性及临床决策一致性。AI辅助测量观察者内和观察者间可重复性完美(RC=0),显著优于传统测量(直径RC 1.9-5.6 mm,体积RC 7.8-22.6 cm³,p<0.001)。AI辅助测量的修复决策一致性(K=1)优于传统测量(K=0.55-0.70),基线AI测量可预测实际修复需求。

要点

  • AI辅助测量腹主动脉瘤直径和体积的观察者内及观察者间可重复性完美,RC=0。
  • AI辅助测量用于修复决策的一致性K=1,传统测量K=0.55-0.70。
  • 基线AI测量预测实际修复需求:直径每增加1 mm,HR 1.12(95%CI 1.03-1.22)。

核心结论

  • 研究提示AI辅助测量腹主动脉瘤大小可提高腹主动脉瘤修复决策的一致性。

研究设计与样本

  • 研究分析了142例患者的CT血管造影扫描,基线142例、1年100例、2年56例、3年4例,使用半自动和AI辅助自动系统,三名观察者用每种方法各测量两次最大腹主动脉瘤直径和体积,参考临床指南决定是否需要修复。

诊断标准与关键数值

  • AI辅助测量的观察者内和观察者间可重复性完美(RC=0),传统测量直径RC为1.9-5.6 mm、体积RC为7.8-22.6 cm³,差异p<0.001;AI辅助测量修复决策一致性K=1,传统测量K=0.55-0.70;基线AI测量预测实际修复需求:直径每增加1 mm,HR 1.12(95%CI 1.03-1.22),体积每增加1 cm³,HR 1.02(95%CI 1.01-1.02),p<0.001。

临床应用与阅片要点

  • 作者认为AI辅助测量腹主动脉瘤大小可提高腹主动脉瘤修复决策的一致性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Decisions to perform abdominal aortic aneurysm (AAA) repair are dependent on aneurysm size, but variation in size measurement leads to inconsistency in management. AI-assisted systems have potential to improve repeatability of measuring aortic dimensions. This study compared the repeatability and agreement in clinical decision-making between using artificial intelligence (AI)-automated and traditional semi-automated methods for measuring abdominal aortic aneurysm (AAA) size.

MATERIALS AND METHODS: Computed tomography angiogram scans from 142 patients who had scans at baseline (n = 142), 1 year (n = 100), 2 years (n = 56) and 3 years (n = 4) were analysed using semi-automated and AI-assisted automated systems. Three observers measured maximal AAA diameter and volume twice with each method. Intra- and inter-observer repeatability were assessed using reproducibility coefficients (RC). Measurements were used to decide if AAA repair was required according to clinical guidelines, and agreement was evaluated using Kappa coefficients (K). The ability of AI-assisted measurements to predict actual requirement for AAA repair was assessed using Cox proportional hazard analysis.

RESULTS: AI-assisted measurements had perfect intra- and inter-observer repeatability (RC = 0) which were significantly superior to traditional measurements (RC for diameter: 1.9-5.6 mm; volume: 7.8-22.6 cm³, p < 0.001). Agreement about AAA repair was superior using AI-assisted (K = 1) than traditional (K = 0.55-0.70) measurements. Baseline AI-assisted measurements predicted actual requirement for AAA repair (Hazard ratio, HR, per mm diameter increase 1.12, 95% confidence intervals, CI, 1.03-1.22, HR per cm³ volume increase 1.02, 95% CI 1.01-1.02, p < 0.001).

CONCLUSION: The findings suggest AI-assisted measurement of AAA size would enhance the consistency of decisions about AAA repair.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Sharma C, Wu M, Enjeti A, et al. Use of artificial intelligence-assisted measurement of aortic diameter in clinical decision making about abdominal aortic aneurysm repair. Abdom Radiol (NY). 2025. PMID: 41454943. doi:10.1007/s00261-025-05275-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。