人工智能辅助冠状动脉CT血管成像的诊断效能:系统综述与Meta分析
本系统综述与Meta分析纳入34项研究共10067例患者,评估AI辅助CCTA检测冠状动脉狭窄的诊断效能。以侵入性冠状动脉造影、侵入性FFR和专家判读为参考,AI-CCTA的合并AUC为0.932,敏感度0.89(95%CI 0.87-0.91),特异度0.80(95%CI 0.74-0.86),诊断OR为37.07(95%CI 24.57-55.92)。与专家判读对照时准确度最高(0.94,95%CI 0.87-0.98);>70%狭窄阈值的准确度0.90、特异度0.96,优于>50%阈值(准确度0.85、特异度0.87)。
要点
- AI辅助CCTA检测冠状动脉狭窄的合并AUC为0.932,敏感度0.89、特异度0.80。
- >70%狭窄阈值下准确度0.90、特异度0.96,优于>50%阈值(准确度0.85、特异度0.87)。
- 以专家判读为参考时AI-CCTA准确度最高,达0.94(95%CI 0.87-0.98)。
核心结论
- AI辅助冠状动脉CT血管成像在冠状动脉狭窄检测中表现出高诊断效能,患者水平和血管水平均具有较高的AUC、敏感度和特异度以及稳健的诊断OR。
研究设计与样本
- 系统综述与Meta分析,检索Web of Science、Scopus、PubMed、Cochrane Library和EMBASE自建库至2025年3月,纳入34项研究共10067例患者,参考标准为侵入性冠状动脉造影、侵入性FFR和专家判读。
诊断标准与关键数值
- 患者水平合并敏感度0.89(95%CI 0.87-0.91),特异度0.80(95%CI 0.74-0.86),诊断OR 37.07(95%CI 24.57-55.92),AUC 0.932。
- 与专家判读对照时准确度0.94(95%CI 0.87-0.98)。
- >70%狭窄阈值准确度0.90、特异度0.96,优于>50%阈值准确度0.85、特异度0.87。
- 血管水平分析AUC为0.905,结果与患者水平相当。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Coronary computed tomography angiography (CCTA) is vital for diagnosing ischemic heart disease, yet its accuracy is unreliable due to varying reader expertise. Artificial Intelligence (AI)-driven automated stenosis assessment offers promise for enhancing diagnostic consistency. We aim to evaluate an AI-CCTA assessment against invasive coronary angiography, invasive FFR, and expert readings.
METHODS: We performed a comprehensive search in Web of Science, Scopus, PubMed, Cochrane Library, and EMBASE from inception until March 2025. Two independent reviewers screened articles and extracted data on study design, patient demographics, AI methodology, stenosis thresholds, and outcomes. For statistical analysis, we constructed summary receiver operating characteristic (SROC) curves and used a bivariate random-effects model to derive pooled sensitivity, specificity, diagnostic odds ratios (DOR), and area under the curve (AUC). Forest plots were generated to visualize these metrics.
RESULTS: Our meta-analysis included 34 studies with 10,067 patients. AI-based CCTA demonstrated excellent diagnostic performance with an AUC of 0.932 for per-patient analysis. The pooled per-patient sensitivity was 0.89 (95 % CI: 0.87-0.91) and specificity was 0.80 (95 % CI: 0.74-0.86) with diagnostic OR of 37.07 (95 % CI: 24.57-55.92). AI validated against expert readers achieved the highest accuracy (0.94, 95 % CI: 0.87-0.98). The > 70 % stenosis threshold demonstrated superior performance (accuracy: 0.90, specificity: 0.96) compared to the > 50 % threshold (accuracy: 0.85, specificity: 0.87). Per-vessel analysis showed comparable results with an AUC of 0.905.
CONCLUSION: AI-assisted coronary CT angiography delivers high diagnostic performance for coronary stenosis detection, with strong AUC values, high sensitivity and specificity, and robust diagnostic OR across both per-patient and per-vessel assessments.
引用
- Hafez A, Sobhy A, Ashour M, et al. Diagnostic Performance of AI-Assisted Coronary CT Angiography: A Systematic Review and Meta-Analysis. Eur J Radiol. 2025. PMID: 41421030. doi:10.1016/j.ejrad.2025.112612
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。