文献速递心血管CTDSA

光子计数探测器CT血管造影诊断阻塞性冠状动脉疾病的准确性:一项贝叶斯诊断试验准确性Meta分析

Accuracy of Photon-counting Detector CT Angiography for the Diagnosis of Obstructive Coronary Artery Disease: A Bayesian Diagnostic Test Accuracy Meta-Analysis.
PubMed 文献 · Radiol Cardiothorac Imaging · 2025-01-01

该贝叶斯诊断试验准确性Meta分析纳入9项研究共843例患者,以有创冠状动脉造影为参考标准,评估光子计数探测器冠状动脉CT血管造影诊断阻塞性冠状动脉疾病的准确性。患者水平汇总敏感度为95.9%、特异度为71.2%,血管水平分别为90.4%和92.8%,节段水平分别为94.1%和93.0%,所有水平AUC均≥0.99;超高分辨率模式下各水平诊断准确性更高。

要点

  • 患者水平汇总敏感度95.9%(95%CrI 90.2–98.7),特异度71.2%(95%CrI 54.0–87.4)。
  • 血管水平敏感度90.4%、特异度92.8%,节段水平敏感度94.1%、特异度93.0%。
  • 超高分辨率模式下各水平诊断准确性均高于整体汇总结果。

核心结论

  • 该贝叶斯诊断试验准确性Meta分析显示,与有创冠状动脉造影相比,光子计数探测器冠状动脉CT血管造影在患者、血管和节段水平均具有诊断准确性。

研究设计与样本

  • 贝叶斯诊断试验准确性Meta分析,纳入所有报告以光子计数探测器冠状动脉CT血管造影为指标试验、有创冠状动脉造影为参考试验的诊断准确性研究,检索PubMed、Embase和Cochrane Library截至2025年2月21日的文献,共纳入9项研究843例患者,采用非信息先验拟合贝叶斯双变量模型,并对超高分辨率光子计数探测器冠状动脉CT血管造影进行亚组分析。

诊断标准与关键数值

  • 患者水平汇总敏感度95.9%(95%CrI 90.2–98.7)、特异度71.2%(95%CrI 54.0–87.4);血管水平敏感度90.4%(95%CrI 83.7–94.5)、特异度92.8%(95%CrI 80.1–97.8);节段水平敏感度94.1%(95%CrI 76.4–99.2)、特异度93.0%(95%CrI 76.3–98.2);各水平AUC均≥0.99;超高分辨率模式下各水平诊断准确性更高。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To analyze the totality of available evidence for the diagnostic accuracy of photon-counting detector (PCD) coronary CT angiography (CCTA) as an index test for the diagnosis of obstructive coronary artery disease, as compared with invasive coronary angiography (ICA). Materials and Methods This Bayesian diagnostic test accuracy (DTA) meta-analysis included all types of studies that reported diagnostic accuracy measures for PCD CCTA as an index test and ICA as a reference test. PubMed, Embase, and Cochrane Library databases were searched for eligible studies published up to February 21, 2025. The primary outcomes were (pooled) sensitivity, specificity, positive and negative likelihood ratio, and diagnostic odds ratio. A Bayesian bivariate model was fitted under a noninformative prior. Subgroup analysis was performed for ultra-high-resolution (UHR) PCD CCTA. Results Nine studies comprising 843 patients were included in the meta-analysis. PCD CCTA demonstrated a pooled sensitivity of 95.9% (95% credible interval [CrI]: 90.2, 98.7) and pooled specificity of 71.2% (95% CrI: 54.0, 87.4) at the patient level; 90.4% (95% CrI: 83.7, 94.5) and 92.8% (95% CrI: 80.1, 97.8), respectively, at the vessel level; and 94.1% (95% CrI: 76.4, 99.2) and 93.0% (95% CrI: 76.3, 98.2), respectively, at the segment level (all area under the receiver operating characteristic curve values ≥ 0.99). These diagnostic accuracy measures were higher across all levels in UHR mode. Conclusion This Bayesian DTA meta-analysis demonstrated the diagnostic accuracy of PCD CCTA, as compared with ICA, at the patient, vessel, and segment levels. Keywords: Coronary Artery Disease, Photon-counting Detector; Coronary Computed Tomography Angiography, Bayesian, Meta-Analysis, Diagnostic Test Accuracy Supplemental material is available for this article. © RSNA, 2025.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Heuts S, Kawczynski MJ, Lemmens MJ, et al. Accuracy of Photon-counting Detector CT Angiography for the Diagnosis of Obstructive Coronary Artery Disease: A Bayesian Diagnostic Test Accuracy Meta-Analysis. Radiol Cardiothorac Imaging. 2025. PMID: 41410572. doi:10.1148/ryct.250313

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。