文献速递心血管USMR

静脉全氟丙烷液滴声学激活成像在大动物缺血/再灌注模型中检测风险区域及最终梗死面积

Acoustic Activation Imaging of Intravenous Perfluoropropane Droplets To Detect Risk Area and Ultimate Infarct Size in a Large Animal Model of Ischemia/Reperfusion.
PubMed 文献 · Ultrasound Med Biol · 2025-12-27

在30头猪的90分钟缺血再灌注模型中,再灌注后30分钟、1天或7天静脉注射全氟丙烷液滴并行声学激活成像;26头出现增强,增强范围显著大于DE-MRI梗死面积且与风险区域相关性更密切(r=0.55,p=0.0002),其中21头增强区内出现低增强区,低增强范围与梗死面积相关(r=0.85,p<0.0001)。

要点

  • 再灌注后静脉注射全氟丙烷液滴行声学激活成像,增强范围与风险区域相关而非最终梗死面积。
  • 增强区内低增强区的空间范围与DE-MRI所测梗死面积高度相关(r=0.85,p<0.0001)。
  • 无论再灌注后30分钟、1天或7天行声学激活,低增强区预测梗死面积的关系一致。

核心结论

  • 静脉全氟丙烷液滴声学激活成像增强再灌注后的风险区域,而增强区内低增强范围可预测梗死面积,且不受再灌注后声学激活时间影响。

研究设计与样本

  • 大动物模型研究:30头猪接受90分钟缺血后再灌注,于再灌注后30分钟、1天或7天静脉注射全氟丙烷液滴并行声学激活成像,以延迟增强磁共振成像(DE-MRI)测定的梗死面积作为参考。

关键影像表现/征象

  • 26头猪再灌注区出现声学激活增强(再灌注后30分钟注射组9/10头、1天组9/10头、7天组8/10头)。
  • 增强范围显著大于DE-MRI所测梗死面积,且与风险区域相关性更密切(r=0.55,p=0.0002)。
  • 26头出现增强的猪中21头增强区内可见低增强区,其空间范围与梗死面积相关(r=0.85,p<0.0001)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Acoustically activatable perfluoropropane droplets (PD) have been utilized to enhance the reperfused zone in acute myocardial infarction small animal models. Despite the correlation with infarct size, the enhanced area consistently overestimates infarct size. We hypothesized that the enhanced area correlates with risk area, and that hypo-enhanced areas (HEA) within the enhanced zone represent the ultimate infarct size.

METHODS: Intravenous PD was administered in the reperfusion period following a 90 min period of ischemia in 30 pigs. Injections were given at either 30 min, 1 d or 7 d following reperfusion to determine what the enhanced regions within the reperfused zone following acoustic activation (AA) were detecting. Correlations of the enhanced and unenhanced regions with the infarct size using delayed enhancement magnetic resonance imaging (DE-MRI) were determined.

RESULTS: AA within the reperfused zone was evident in 26 pigs (9/10 pigs injected at 30 min post-reperfusion, 9/10 pigs injected at 1 d and 8/10 pigs injected at 7 d). In the 26 pigs with AA, the extent of enhancement was significantly larger than the infarct size by DE-MRI, and correlated more closely with risk area (r = 0.55, p = 0.0002). A HEA within the enhanced region was observed in 21 of the 26 pigs with AA, and the spatial extent of HEA correlated with infarct size (r = 0.85; p < 0.0001).

CONCLUSION: AA of intravenous PD enhances the risk area following reperfusion. However, it is the extent of hypo-enhancement within the enhanced region that predicts infarct size irrespective of the time AA is performed following reperfusion.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Li S, Chen C, Lof J, et al. Acoustic Activation Imaging of Intravenous Perfluoropropane Droplets To Detect Risk Area and Ultimate Infarct Size in a Large Animal Model of Ischemia/Reperfusion. Ultrasound Med Biol. 2025. PMID: 41455684. doi:10.1016/j.ultrasmedbio.2025.10.016

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。