文献速递心血管CT

心脏CT衍生主动脉瓣面积与主动脉瓣钙化评分对低梯度主动脉瓣狭窄诊断参数的比较

Comparison of Diagnostic Parameters Using Cardiac CT-derived Aortic Valve Area and Aortic Valve Calcium Scores for Low-Gradient Aortic Stenosis.
PubMed 文献 · Radiol Cardiothorac Imaging · 2025-01-01

本回顾性分析纳入2018年11月至2022年3月间接受超声心动图和心脏CT的215例低梯度主动脉瓣狭窄(平均梯度<40 mmHg)患者,比较混合主动脉瓣面积(AVA)及平面测量法联合主动脉瓣钙化(AVC)或AVC密度(AVCd)的评估性能。随访中位478天,74.4%患者发生复合终点。结论:混合AVA联合AVC或AVCd的诊断策略性能相当,指数化混合AVA优于绝对值AVA。

要点

  • 指数化AVA指标优于绝对值AVA,联合AVC时风险比最高达2.29(95%CI 1.66-3.15)。
  • 所有模型Harrell C统计量相当(0.55-0.60),区分度有限。
  • 混合AVA联合AVC或AVCd对低梯度主动脉瓣狭窄评估性能相当。

核心结论

  • 混合AVA联合AVC或AVCd在低梯度主动脉瓣狭窄评估中性能相当;指数化混合AVA单独或联合AVC均优于绝对值AVA。

研究设计与样本

  • 回顾性分析纳入215例低梯度主动脉瓣狭窄(平均梯度<40 mmHg)患者,均接受超声心动图和心脏CT检查,时间范围为2018年11月至2022年3月。

诊断标准与关键数值

  • 最高性能模型为指数化AVA(基于CT最小直径推导的左室流出道面积)联合绝对AVC:风险比2.29(95%CI 1.66-3.15,P<.001),C统计量0.60;最低性能模型为绝对AVA平面测量法联合AVCd:风险比1.62(95%CI 1.19-2.22,P=.002),C统计量0.55。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To compare the performance of cardiac CT-derived hybrid aortic valve area (AVA) and planimetry, in combination with aortic valve calcium (AVC) or AVC density (AVCd), for assessing low-gradient aortic stenosis (LGAS). Materials and Methods This retrospective analysis included patients with LGAS (mean gradient < 40 mm Hg) who underwent echocardiography and cardiac CT from November 2018 to March 2022. The performance of absolute and indexed hybrid AVA and planimetry, combined with either absolute AVC or AVCd, was compared by time-to-event analysis and outcome classification ability. Results A total of 215 patients (mean age, 79.2 years ± 8.4 [SD]; 118 male patients) were included in the study. Of these, 74.4% (160 of 215) experienced a composite outcome of valve intervention or all-cause mortality during follow-up. Specifically, 11% (23 of 215) underwent surgical aortic valve replacement, 59% (126 of 215) underwent transcatheter aortic valve replacement, and 15% (32 of 215) died. The median follow-up duration was 478 days (IQR, 283-716 days). Indexed AVA measures performed better than absolute AVA. All models showed comparable discrimination, as measured by Harrell C statistic. The highest performing model was indexed AVA calculated using left ventricular outflow tract area derived from minimum CT diameter combined with absolute AVC (hazard ratio, 2.29; 95% CI: 1.66, 3.15; P < .001; C statistic, 0.60). The lowest performing model was absolute AVA planimetry with AVCd (hazard ratio, 1.62; 95% CI: 1.19, 2.22; P = .002; C statistic, 0.55). Conclusion Diagnostic strategies involving hybrid AVA and AVC or AVCd demonstrated comparable performance in LGAS assessment. Indexed hybrid AVA measures performed better alone or in combination with AVC compared with the absolute AVA measures. Keywords: Aortic Valve Calcium, Cardiac CT, Low-Gradient Aortic Stenosis Supplemental material is available for this article. © RSNA, 2025.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Ahmad S, Watson H, Awad M, et al. Comparison of Diagnostic Parameters Using Cardiac CT-derived Aortic Valve Area and Aortic Valve Calcium Scores for Low-Gradient Aortic Stenosis. Radiol Cardiothorac Imaging. 2025. PMID: 41379009. doi:10.1148/ryct.250071

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。