文献速递心血管CT

脉搏血氧仪触发冠状动脉CT血管成像可行性的评估

Evaluation on the Feasibility of the Pulse Oximetry-triggered Coronary CT Angiography.
PubMed 文献 · Radiol Cardiothorac Imaging · 2025-01-01

前瞻性研究纳入300例拟行冠状动脉CT血管成像的连续参与者,比较脉搏血氧仪触发(基于心率监测模拟虚拟心电信号)与传统心电触发两组,在16 cm z轴覆盖CT上使用运动校正和深度学习图像重建算法。两组辐射剂量和对比剂剂量无差异,主冠状动脉血管的CT衰减、图像噪声、信噪比、对比噪声比及总体图像质量相当(均P > .05),脉搏血氧仪触发组总检查时间显著低于心电触发组(313.23秒 ± 59.59秒 vs 743.25秒 ± 75.35秒,P < .001)。

要点

  • 脉搏血氧仪触发组总检查时间313.23秒 ± 59.59秒,显著低于心电触发组的743.25秒 ± 75.35秒(P < .001)。
  • 两组辐射剂量和对比剂剂量差异无统计学意义(均P > .05)。
  • 两组主冠状动脉血管的CT衰减、图像噪声、信噪比、对比噪声比及总体图像质量相当(均P > .05)。

核心结论

  • 在16 cm z轴覆盖CT上,采用脉搏血氧仪触发方案联合心脏运动校正算法和深度学习图像重建算法行冠状动脉CT血管成像,图像质量与传统心电触发相当,辐射剂量和对比剂剂量相似,同时显著缩短检查时间。

研究设计与样本

  • 前瞻性研究,纳入2023年6月至7月拟行冠状动脉CT血管成像的连续参与者300例(平均年龄57岁 ± 12岁;161例男性),在16 cm z轴覆盖CT上扫描,半数(n = 150)接受基于脉搏血氧仪心率监测模拟虚拟心电信号触发的冠状动脉CT血管成像(脉搏血氧仪触发组),另半数(n = 150)接受传统心电触发冠状动脉CT血管成像(心电组),所有图像采用运动校正和深度学习图像重建算法重建。

诊断标准与关键数值

  • 脉搏血氧仪触发组(n = 150)总检查时间313.23秒 ± 59.59秒 vs 心电组(n = 150)743.25秒 ± 75.35秒,脉搏血氧仪触发组显著降低(P < .001)。
  • 脉搏血氧仪触发组与心电组辐射剂量和对比剂剂量差异无统计学意义(均P > .05)。
  • 脉搏血氧仪触发组与心电组主冠状动脉血管的CT衰减、图像噪声、信噪比、对比噪声比及总体图像质量差异无统计学意义(均P > .05)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To evaluate the feasibility of performing pulse oximetry-triggered coronary CT angiography (CCTA) for diagnostic imaging in cardiac participants who cannot or have difficulty being connected to electrocardiographic (ECG) devices. Materials and Methods This prospective study enrolled consecutive participants scheduled for CCTA on a 16-cm z-axis coverage CT from June to July 2023. Half of the study participants underwent CCTA triggered by a simulated virtual ECG signal based on heart rate monitoring via pulse oximetry (pulse oximetry-triggered group), and the other half underwent traditional ECG-triggered CCTA (ECG group). All images were reconstructed using motion correction and deep learning image reconstruction algorithms. Comparisons were made regarding radiation dose, contrast agent dose, examination time, and subjective and objective image quality assessments between the two groups. Results Three hundred participants (mean age ± SD, 57 years ± 12; 161 male) were included. The total examination time of the pulse oximetry-triggered group (n = 150) was significantly lower than that of the ECG group (n = 150) (313.23 seconds ± 59.59 s vs 743.25 seconds ± 75.35; P < .001). There was no evidence of a difference between the pulse oximetry-triggered and ECG groups in terms of radiation and contrast media dose (all P > .05). The pulse oximetry-triggered and ECG groups had comparable values for CT attenuation, image noise, signal-to-noise ratio, and contrast-to-noise ratio of the main coronary vessels, as well as overall image quality (all P > .05). Conclusion The study demonstrated that CCTA with the pulse oximetry-triggered protocol on a 16-cm z-axis coverage CT with cardiac motion correction algorithm and deep learning image reconstruction algorithms provide comparable image quality to traditional ECG-triggered CCTA at similar radiation and contrast doses while significantly reducing examination time. Keywords: Applications-CT, CT-Angiography, CT-Coronary Angiography Supplemental material is available for this article. © RSNA, 2025.

来源:Radiol Cardiothorac Imaging,查看原文。版权归原作者所有。

引用

  1. Zhang Y, Zhang W, Wang L, et al. Evaluation on the Feasibility of the Pulse Oximetry-triggered Coronary CT Angiography. Radiol Cardiothorac Imaging. 2025. PMID: 41379007. doi:10.1148/ryct.240495

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。