第四版通用定义心电图标准识别陈旧性心肌梗死的诊断准确性
本回顾性研究以心脏MRI为参考标准,评估12导联心电图第四版通用定义标准检测、量化和定位陈旧性心肌梗死的诊断准确性。1038例患者中,心电图检测陈旧性心肌梗死的准确性78.6%,特异度88.4%,敏感度39.4%,仅检出40.2%的透壁性梗死和12.3%的心内膜下梗死,侧壁和下壁漏诊率较高。
要点
- 心电图诊断陈旧性心肌梗死特异度88.4%但敏感度仅39.4%,准确性78.6%。
- 心内膜下梗死检出率12.3%,透壁性梗死检出率40.2%。
- 侧壁(漏诊69.3%)和下壁(漏诊52.3%)梗死漏诊率最高。
核心结论
- 第四版通用定义心电图标准检测陈旧性心肌梗死具有高特异度但敏感度有限,尤其对心内膜下梗死和侧壁梗死。
研究设计与样本
- 回顾性研究纳入2018年1月至2020年8月连续转诊行心脏MRI并记录数字心电图的1038例患者(中位年龄63岁,IQR 52-75岁,女性405例),以心脏MRI晚期钆增强按17节段模型为参考标准,两名盲法心脏科医师独立应用第四版通用定义心电图标准识别陈旧性心肌梗死。
关键影像表现/征象
- 心电图检出全部透壁性陈旧性心肌梗死的40.2%,检出全部心内膜下陈旧性心肌梗死的12.3%。
- 心电图未检出208例陈旧性心肌梗死患者中的126例(60.6%),侧壁未检出69.3%、下壁未检出52.3%。
- 心电图未检出72.6%的心内膜下陈旧性心肌梗死和48.0%的透壁性陈旧性心肌梗死。
- 完全性左或右束支传导阻滞存在时检出率进一步下降。
- 非特异性传导障碍在陈旧性心肌梗死患者中更常见(5.3% vs 1.6%,P=0.003),透壁性陈旧性心肌梗死患者中更常见(6.9% vs 1.6%,P=0.002)。
诊断标准与关键数值
- 心电图检测陈旧性心肌梗死的准确性78.6%,特异度88.4%,敏感度39.4%。
- 诊断标准为第四版心肌梗死通用定义心电图标准,以心脏MRI晚期钆增强为参考标准。
临床应用与阅片要点
- 解读心电图时需注意第四版通用定义标准对心内膜下梗死和侧壁、下壁梗死的敏感度有限。
- 完全性左或右束支传导阻滞及非特异性传导障碍可能进一步降低心电图对陈旧性心肌梗死的检出能力。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To assess the diagnostic accuracy of 12-lead electrocardiography (ECG) in detecting, quantifying, and localizing prior myocardial infarction (pMIs) using cardiac MRI as the reference standard. Materials and Methods In this retrospective study, consecutive patients referred for cardiac MRI and their recorded digital ECGs were evaluated between January 2018 and August 2020. Patients underwent cardiac MRI assessment for coronary artery disease or cardiomyopathy. Late gadolinium enhancement was assessed across a 17-segment heart model for patients with and without ischemia. Two blinded cardiologists independently applied the fourth universal definition of myocardial infarction ECG criteria to identify pMIs. Diagnostic accuracy of ECG in detecting pMI was assessed by calculating accuracy, sensitivity, and specificity; χ2 test was used to assess the independence of observed frequencies. Results Among 1038 patients (median age, 63 years; IQR, 52-75 years, 405 female patients), ECG detection accuracy for pMI was 78.6% (88.4% specificity and 39.4% sensitivity). Using ECG, 40.2% of all transmural pMIs and 12.3% of all subendocardial pMIs were detected. ECG did not detect pMIs in 126 of 208 (60.6%) patients, particularly in the lateral (69.3%) and inferior (52.3%) regions. ECG did not detect 72.6% and 48.0% of subendocardial and transmural pMIs, respectively. Detection rates decreased further in the presence of complete left or right bundle branch block. Nonspecific conduction disturbances were more common in patients with pMIs (5.3% vs 1.6%, P = .003), especially those with transmural pMIs (6.9% vs 1.6%, P = .002). Conclusion The Fourth Universal Definition of Myocardial Infarction ECG criteria provided high specificity but limited sensitivity for detecting pMI, particularly subendocardial and lateral infarcts. Keywords: Electrocardiogram, Cardiovascular Magnetic Resonance, Myocardial Infarction, Late Gadolinium Enhancement, Fourth Universal Definition of Myocardial Infarction Supplemental material is available for this article. © RSNA, 2025.
引用
- Segeroth M, Badertscher P, Strebel I, et al. Diagnostic Accuracy of Fourth Universal Definition ECG Criteria for Identifying Prior Myocardial Infarction. Radiol Cardiothorac Imaging. 2025. PMID: 41410574. doi:10.1148/ryct.250082
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。