文献速递技术与安全MR

体内pi-SSelMQC技术从两条MQ相干转移路径恢复100%生物标志物信号及其在肿瘤乳酸成像中的应用

In Vivo pi-SSelMQC to Recover 100% Biomarker Signals From Both MQ Coherence Transfer Pathways with Applications in Tumor Lactate Imaging.
PubMed 文献 · Acad Radiol · 2025-12-20

研究开发了相位增量软选择多量子相干转移(pi-SSelMQC)方法,在体模和鼠源性344SQ肺癌模型中同步检测ZQ→DQ与DQ→ZQ两条相干转移路径的乳酸和PUFA信号,实现100%信号恢复,并利用频率编码将笛卡尔坐标数据采集速度提高10-20倍,同时保持优异的脂质和水抑制。

要点

  • pi-SSelMQC通过相位编码梯度与RF相位增量同步,可同时检测ZQ→DQ和DQ→ZQ两条路径的乳酸信号,恢复100%生物标志物信号。
  • 双回波pi-SSelMQC采集方案在有读出梯度时提供优异的脂质和水抑制,并实现两条MQ路径100%信号恢复。
  • 频率编码使笛卡尔坐标数据采集速度提高10-20倍,乳酸信号被引入相反成像偏移以远离水、脂质等重叠信号。

核心结论

  • pi-SSelMQC方法可利用相位增量技术同时检测来自两条不同MQ相干转移路径的生物标志物图像并实现100%信号恢复;快速双回波采集结合频率编码可加速癌症生物标志物成像并保持优异的脂质和水抑制;该新方法可能用于监测癌症治疗反应及研究肿瘤乳酸产生与癌症免疫逃逸的关系。

研究设计与样本

  • 方法学研究,在体模(酸奶样本用于乳酸、大豆油体模用于PUFA)和体内动物肿瘤模型(同系129X1/SvJ雄性小鼠右大腿皮下生长的鼠源性344SQ肺癌模型)中验证单回波或双回波pi-SSelMQC方法,并与Sel-MQC方法(CSI或快速Spiral-SelMQC)进行比较。

诊断标准与关键数值

  • 通过将相位编码梯度步与选择性MQ激发90˚脉冲或MQ转移90˚脉冲的RF相位增量同步,在酸奶样本和体内344SQ肿瘤中检测到来自ZQ→DQ和DQ→ZQ两条相干转移路径的乳酸。
  • 对来自两条不同MQ相干转移路径的乳酸信号引入相反成像偏移,使乳酸图像远离水、脂质或其他重叠生化物质的不需要信号,从而使笛卡尔坐标频率编码数据采集速度提高10-20倍。
  • 在有读出梯度时,新型双回波pi-SSelMQC采集方案提供优异的脂质和水抑制,并从两条MQ相干转移路径实现100%生物标志物信号恢复。
  • pi-SSelMQC方法在大豆油体模中恢复100% PUFA信号。

临床应用与阅片要点

  • 作者认为,快速双回波采集结合频率编码梯度可用于加速癌症生物标志物成像并保持优异的脂质和水抑制。
  • 作者认为,新型pi-SSelMQC方法可能用于监测癌症治疗反应及研究肿瘤乳酸产生与癌症免疫逃逸的关系。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: The Warburg Effect and lactate production in human cancer have a profound impact on tumor microenvironment modulation and cancer immune evasion. Lactate level changes during cancer therapies have been investigated in animal tumor models as an early predictive biomarker of treatment responses. Previously, non-invasive selective multiple quantum coherence transfer (Sel-MQC) methods were developed for in vivo lactate or polyunsaturated fatty acids (PUFA) imaging in tumors using chemical shift imaging (CSI) or fast Spiral-SelMQC methods. The Sel-MQC offers excellent single-scan suppression of intensive lipid and water signals. In current Sel-MQC imaging, however, only one of the Double-Quantum (DQ)→ Zero-Quantum (ZQ) and ZQ→DQ coherence transfer pathways can be detected at a time, resulting in a loss of biomarker signal by a factor of one-half when imaging lactate in tissues containing high level of mobile lipid. To recover 100% signal and improve in vivo biomarker imaging sensitivity, a fast MRSI imaging technique is needed for simultaneous detection of ZQ→DQ and DQ→ZQ coherence transfer pathways. In this research project, we have developed novel phase-incrementing soft selective multiple quantum coherence transfer (pi-SSelMQC) methods to detect full biomarker signal from both MQ-coherence transfer pathways with excellent water and lipid suppression with demonstrations in phantoms and tumor lactate imaging.

MATERIALS AND METHODS: The pi-SSelMQC methods with a single-echo or double-echo acquisitions were demonstrated in phantoms and in vivo in animal tumor models. The biomarker lactate and PUFA images were obtained from yogurt samples and soybean oil phantoms, respectively. In vivo lactate imaging was carried out using the murine 344SQ lung cancer model grown subcutaneously on the right thigh of syngeneic 129X1/SvJ male mouse.

RESULTS: Lactate from both ZQ→DQ and DQ→ZQ coherence transfer pathways was detected in yogurt samples and in vivo in 344SQ tumors by synchronizing the phase-encoding gradient steps with the RF phase incrementations of the selective MQ-excitation 90˚ pulse or the MQ-transfer 90˚ pulse. Opposite imaging offsets were introduced to the lactate signals from the two different MQ-coherence transfer pathways, moving lactate images away from unwanted signals from water, lipid, or other overlapping biochemicals. This permits frequency-encoding to speed up data acquisition by 10-20 times in Cartesian coordinates. The pi-SSelMQC methods were also applied to recover 100% PUFA signals from soybean oil phantoms. In the presence of readout-gradients, the novel double-echo pi-SSelMQC acquisition scheme offers excellent lipid and water suppression, as well as 100% biomarker signal recovery from both MQ-coherence transfer pathways.

CONCLUSION: The biomarker images from the two different MQ-coherence transfer pathways can be simultaneously detected by the pi-SSelMQC methods with 100% signal recovery using phase-incrementing technique. The fast double-echo acquisition with frequency-encoding gradients may be employed to speed up cancer biomarker imaging with excellent lipid and water suppression. The novel pi-SSelMQC methods may be employed to monitor cancer treatment responses and investigate the relationship of tumor lactate production and cancer immune evasion.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. He Q, Yuan H, Zhang X, et al. In Vivo pi-SSelMQC to Recover 100% Biomarker Signals From Both MQ Coherence Transfer Pathways with Applications in Tumor Lactate Imaging. Acad Radiol. 2025. PMID: 41423359. doi:10.1016/j.acra.2025.11.042

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。