文献速递胸部CT

全容积双能CT定量参数列线图能否预测纯实性浸润性肺腺癌的新IASLC分级

Can full-volume dual-energy CT quantitative parameter nomogram predict the new IASLC grade of pure solid invasive pulmonary adenocarcinoma.
PubMed 文献 · Br J Radiol · 2026-01-01

本研究回顾性分析161例纯实性型非黏液性浸润性肺腺癌患者的术前临床与影像资料,利用全容积双能CT定量参数建立列线图模型,以预测国际肺癌研究协会(IASLC)分级。模型在训练组和测试组的AUC分别为0.884(95%CI:0.826-0.943)和0.848(95%CI:0.738-0.958)。

要点

  • 全容积双能CT定量参数列线图有助于区分高级别与低级别非黏液性浸润性肺腺癌。
  • 模型在训练组AUC为0.884(95%CI:0.826-0.943),测试组AUC为0.848(95%CI:0.738-0.958)。
  • 体积、光谱曲线斜率(λ40keV-100keV)和标准化碘浓度(NIC)是独立特征变量。

核心结论

  • 基于双能CT定量参数的列线图可有效区分高级别与低级别非黏液性浸润性肺腺癌,为临床决策提供潜在价值。

研究设计与样本

  • 回顾性分析2021年9月至2024年5月161例纯实性型非黏液性浸润性肺腺癌患者的术前临床和影像数据,使用半自动软件对病灶进行全容积分割并记录双能CT定量参数,通过单因素和多因素logistic回归筛选独立特征变量并构建多参数模型。

诊断标准与关键数值

  • 体积、光谱曲线斜率(λ40keV-100keV)和标准化碘浓度(NIC)被确定为区分低级别与高级别非黏液性浸润性肺腺癌的独立特征变量。
  • 基于上述3个变量构建的列线图在训练组AUC为0.884(95%CI:0.826-0.943),在测试组AUC为0.848(95%CI:0.738-0.958)。

临床应用与阅片要点

  • 作者认为该列线图可有效区分高级别与低级别非黏液性浸润性肺腺癌,为临床决策提供潜在价值。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study aimed to develop and construct a predictive model based on the quantitative parameters of full-volume dual-energy computed tomography (DECT) to forecast the International Association for the Study of Lung Cancer classification of non-mucinous invasive pulmonary adenocarcinoma (IPA).

METHODS: The preoperative clinical and imaging data of 161 patients with pure solid type non-mucinous IPA from September 2021 to May 2024 were retrospectively analysed. The semiautomated software was used to perform full-volume segmentation of the lesions and the associated DECT quantitative parameters were recorded. Through univariate and multivariate logistic regression analyses, we identified independent characteristic variables that distinguished high-grade from low-grade non-mucinous IPA. We subsequently used these characteristic variables to construct a multiparameter model.

RESULTS: Volume, slope of the spectral curve (λ40keV-100keV) and normalized iodine concentration (NIC) were identified as independent feature variables to distinguish low-grade and high-grade non-mucinous IPA. By utilizing these 3 variables, we constructed a quantitative visualization nomogram to distinguish the new IASLC grade of non-mucinous IPA. The model exhibited excellent performance in both the training and testing groups, with area under the curve (AUC) values of 0.884 (95% CI: 0.826-0.943) and 0.848 (95% CI: 0.738-0.958), respectively.

CONCLUSION: This study successfully established and validated a nomogram based on DECT quantitative parameters, which can effectively differentiate high-grade and low-grade non-mucinous IPA and provides potential value for clinical decision-making.

ADVANCES IN KNOWLEDGE: This study is the first attempt to apply a nomogram based on DECT to assess the invasiveness of non-mucous IPA.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Liu K, Fang N, Cao Y, et al. Can full-volume dual-energy CT quantitative parameter nomogram predict the new IASLC grade of pure solid invasive pulmonary adenocarcinoma. Br J Radiol. 2026. PMID: 41365825. doi:10.1093/bjr/tqaf303

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。